Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Arq. bras. oftalmol ; 83(5): 383-388, Sept.-Oct. 2020. tab, graf
Article in English | LILACS | ID: biblio-1131623

ABSTRACT

ABSTRACT Purpose: This study aimed to evaluate optic nerve head parameters and inner retinal layer thicknesses in obese children and adolescents. Methods: Forty-one eyes of 41 pediatric obese participants and 41 eyes of 41 age- and sex-matched healthy controls were included in this study. Body mass index was calculated, based on sex and age, using body weight and height measurements. Blood lipid values (i.e., cholesterol, low-density lipoprotein, high-density lipoprotein, and triglyceride) were measured in obese participants. Optical coherence tomography was used to examine optic nerve head parameters, including rim area, disc area, cup-to-disc ratio, and cup volume, as well as the thicknesses of retinal nerve fiber layers and macular ganglion cell-inner plexiform layers. Results: Optic disc parameters were similar in obese and healthy children (p>0.05). The percentage of binocular retinal nerve fiber layer thickness symmetry was significantly different between obese and control groups (p=0.003). Compared to the control group, participants in the obese group exhibited thinner retinal nerve fiber layers in the superior quadrants (p=0.04) and thinner ganglion cell-inner plexiform layers in the superior-temporal sectors (p=0.04). There were no statistically significant correlations between the ocular parameters and lipid blood test values assessed in this study (p>0.05). Body mass index was significantly negatively correlated with the mean retinal nerve fiber layer thickness (r=-0.33, p=0.03) in the obese group. There was no significant correlation between intraocular pressure and body mass index (r=0.05, p=0.74). Conclusion: Compared to healthy children, obese children had greater binocular retinal nerve fiber layer thickness asymmetry and thinner retinal nerve fiber and ganglion cell-inner plexiform layers in several sectors. Blood lipid levels were not associated with retinal thickness or optic disc parameters in obese children.


RESUMO Objetivo: O objetivo deste estudo foi avaliar os parâmetros da cabeça do nervo óptico e a espessura da camada interna da retina em crianças e adolescentes obesos. Métodos: Quarenta e um olhos de 41 participantes pediátricos obesos e 41 olhos de 41 controles saudáveis pareados por idade e sexo foram incluídos neste estudo. O índice de massa corporal foi calculado com base no sexo e na idade, utilizando medidas de peso e estatura corporal. Os valores de lipídios no sangue (colesterol, lipoproteína de baixa e alta densidade e triglicérides) foram medidos nos participantes obesos. A tomografia de coerência óptica foi usada para examinar os parâmetros da cabeça do nervo óptico, incluindo a área da borda, área do disco, razão escavação/disco, volume da escavação, espessura s camadas de fibra nervosa da retina e as camadas plexiformes internas das células ganglionares da mácula. Resultados: Os parâmetros do disco óptico foram semelhantes em crianças obesas e saudáveis (p>0,05). A porcentagem da simetria da espessura da camada de fibras nervosas da retina binocular foi significativamente diferente entre os grupos obesos e controle (p=0,003). Comparados ao grupo controle, os participantes do grupo obeso exibiram camadas mais finas de fibras nervosas da retina nos quadrantes superiores (p=0,04) e camadas plexiformes mais finas da célula ganglionar interna nos setores temporal superior (p=0,04). Não houve correlação significante entre os parâmetros oculares e os valores dos exames de sangue lipídico avaliados neste estudo (p>0,05). O índice de massa corporal foi significativamente correlacionado negativamente com a espessura média da camada de fibras nervosas da retina (r=-0,33, p=0,03) no grupo obeso. Não houve correlação significativa entre a pressão intraocular e o índice de massa corporal (r=0,05, p=0,74). Conclusão: Comparadas às crianças saudáveis, as crianças obe sas apresentaram maior assimetria binocular na espessura da ca mada de fibras nervosas da retina e fibras nervosas da retina mais finas e camadas plexiformes internas das células ganglionares em vários setores. Os níveis de lipídios no sangue não foram associados à espessura da retina ou aos parâmetros do disco óptico em crianças obesas.


Subject(s)
Humans , Adolescent , Adult , Optic Disk , Obesity , Optic Disk/anatomy & histology , Optic Disk/diagnostic imaging , Retina , Retinal Ganglion Cells , Tomography, Optical Coherence , Nerve Fibers , Obesity/complications
2.
Arq. bras. oftalmol ; 82(4): 270-274, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019408

ABSTRACT

ABSTRACT Purpose: We aimed to compare the thickness of anterior sclera, corneal layers, and pre-ocular tear film between patients with primary Sjögren's syndrome and healthy individuals. Methods: Fifty-one patients with primary Sjögren's syndrome and 41 healthy control participants were recruited in this cross-sectional and comparative study. The thickness of the pre-ocular tear film, corneal epithelium, Bowman's layer, stroma, Descemet's membrane, and endothelium were measured on the corneal apex. Anterior scleral thickness was measured at distances of 1 mm and 3 mm from the limbus. The anterior segment module of spectral-domain optical coherence tomography was used to measure thicknesses of pre-ocular tear film, corneal layers, and anterior sclera. Results: Tear film thickness, Schirmer's test, and tear break up time values were significantly lower in the Sjögren's disease group than in the healthy controls (p<0.05). The thickness measurements of corneal layers and sclera were similar between the groups. Tear film thickness was moderately correlated with the Schirmer's test results (r=0.34, p=0.001), but there was no correlation between the Schirmer's test results and tear break up time (r=0.18, p=0.09). Conclusions: Pre-ocular tear film, as measured by anterior segment optical coherence tomography, was thinner in patients with primary Sjögren's syndrome than in the healthy controls. The thicknesses of corneal layers and anterior sclera were similar between the groups.


RESUMO Propósito: Nosso objetivo foi comparar a espessura da esclera anterior, camadas da córnea e do filme lacrimal pré-ocular entre pacientes com síndrome de Sjögren primária e indivíduos saudáveis. Métodos: Cinquenta e um pacientes com síndrome de Sjögren primária e 41 controles saudáveis foram recrutados neste estudo comparativo e transversal. A espessura do filme lacrimal pré-ocular, epitélio corneal, camada de Bowman, estroma, membrana de Descemet e endotélio foram medidos no ápice corneal. A espessura da esclera anterior foi medida às distâncias de 1 mm e 3 mm do limbo. O módulo do segmento anterior da tomografia de coerência óptica de domínio espectral foi utilizado para mensurar as espessuras do filme lacrimal pré-ocular, camadas da córnea e esclera anterior. Resultados: A espessura do filme lacrimal, o teste de Schirmer e os valores do tempo de ruptura do filme lacrimal foram significativamente menores no grupo com síndrome de Sjögren do que nos controles saudáveis (p<0,05). As medidas de espessura das camadas corneais e da esclera foram similares entre os grupos. A espessura do filme lacrimal foi moderadamente correlacionada com os resultados do teste de Schirmer (r=0,34, p=0,001), mas não houve correlação entre os resultados do teste de Schirmer e tempo de ruptura (r=0,18, p=0,09). Conclusões: O filme lacrimal pré-ocular, medido pela tomografia de coerência óptica de segmento anterior, foi mais fino em pacientes com síndrome de Sjögren primária do que nos controles saudáveis. As espessuras das camadas da córnea e da esclera anterior foram semelhantes entre os grupos.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Sclera/pathology , Sjogren's Syndrome/pathology , Cornea/pathology , Reference Values , Sclera/diagnostic imaging , Tears/physiology , Sjogren's Syndrome/physiopathology , Case-Control Studies , Cross-Sectional Studies , Cornea/diagnostic imaging , Tomography, Optical Coherence/methods
SELECTION OF CITATIONS
SEARCH DETAIL