1.
Braz. j. med. biol. res ; 33(3): 341-6, Mar. 2000. ilus
Article in English | LILACS | ID: lil-255053

ABSTRACT

A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25 per cent corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.


Subject(s)
Humans , Echocardiography, Doppler, Color , Heart Valve Diseases , Heart Valve Prosthesis , Models, Cardiovascular , Pulsatile Flow , Blood Pressure , Heart Atria
2.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.359-360, graf.
Monography in Portuguese | LILACS | ID: lil-236393

ABSTRACT

O ultra-som é uma das principais ferramentas para diagnósticos na área médica. Através da interação dos campos ultra-sônicos pode-se obter várias características dos tecidos biológicos, portanto é importante conhecer sua distribuição de pressão no meio de propagação. Neste trabalho é estudado o campo ultra-sônico produzido por um transdutor piezoelétrico anular. Os resultados experimentais mostram que o campo ultra-sônico depende do material empregado na construção do transdutor.


The ultrasound is a important tool for diagnostics on medical area. Throught of ultrasonic fiel d interaction we can obtain some characteristics of the biologycal tissues, thus it is important to know the pressure distribuition in the propagation medium. ln this paper is studied the ultrasonic field generated by a ring piezoelectric transducer. The experimental results show the ultrasonic field depends of the material employed in the transducer construction.


Subject(s)
Transducers , Ultrasonography , Acoustic Stimulation/adverse effects , Metal Ceramic Alloys , Vibration
3.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.517-518, graf.
Monography in Portuguese | LILACS | ID: lil-233847

ABSTRACT

Uma câmara de ionização de 23 cm3 com ar comprimido e parede de alumínio foi construída e apresenta sensibilidade uma ordem de grandeza maior quando comparada a câmaras de mesmo volume à pressão ambiente. A utilização de ar a uma pressão 2500 KPa minimiza sua dependência energética que se mantém menor que 5 por cento para energias de fótons na faixa de 40 KeV a 1.250 KeV. Esta câmara apresenta melhor desempenho do que as câmaras convencionais em medidas de baixas taxas de exposição.


Subject(s)
Radiometry/statistics & numerical data , Dosimetry , Aluminum , Air Ionization/radiation effects , Calibration , Cobalt/radiation effects , Gamma Rays
4.
s.l; Associaçäo Brasileira de Físicos em Medicina; 1989. 261 p. tab.
Monography in Portuguese | LILACS | ID: lil-99558

ABSTRACT

A idéia de se utilizar eletreto em detecçäo e dosimetria das radiaçöes ionizantes foi patenteada em 1954. Devido a baixa sensibilidade a radiaçäo dos eletretos existentes, näo houve uma utilizaçäo prática até os trabalhos de Fabel e Henisch, que usaram folhas de TEFLON e PVDF, encontrando sensibilidades muito mais altas que os dosimetros termoluminescentes. Os trabalhos desenvovlidos e publicados desde entäo trouxeram um progresso considerável na área de detecçäo e dosimetria com eletretos. Dentre os quais destacamos os trabalhos de Bauser, Gross, Gross, Ikeya, Kotrappa, Mascarenhas, Zimmerman, Cameron, Pretsch, Pelá e outros. Mais recentemente, uma câmara de ionizaçäo cilíndrica co m uma camada de boro depositada em sua parede interna, que permite detectar e fazer dosimetria de neutrons térmicos foi desenvolvido. Esta última referência apresenta uma completa revisäo até o presente da detecçäo e dosimetria utilizando eletretos. O objetivo deste trabalho é apresentar uma análise numérica com relaçäo a resposta da câmara de ionizaçäo de eletretos para detecçäo de neutrons térmicos


Subject(s)
Radiation Dosage , Electrons , Neutrons , Radiometry/instrumentation , Numerical Analysis, Computer-Assisted