Chinese Journal of Ultrasonography ; (12): 67-72, 2023.
Article in Chinese | WPRIM | ID: wpr-992807

ABSTRACT

Objective:To construct a nomogram for predicting the occurrence of renal allograft rejection based on the combination of multimodal ultrasound features and clinical data.Methods:The ultrasound findings and clinical characteristics of 102 patients with transplanted kidneys who underwent renal biopsy in the General Hospital of Eastern Theater Command from January 2021 to March 2022 were analyzed retrospectively. Patients were divided into rejection group and nephropathy group according to Banff transplant kidney pathological diagnostic criteria (2017 edition). Multivariate Logistic regression was used to screen independent predictors related to the status of rejection, and nomograms were drawn based on the independent predictors. The internal validation of the nomogram was carried out by Bootstrap method, and the ROC curve and calibration curve were utilized to evaluate the diagnostic efficacy of the nomogram.Results:Blood urea nitrogen concentration, renal aortic resistance index, absolute time to peak and cortical echo were independent predictors of rejection( OR=1.073, 1.078, 0.843, 0.205; all P<0.05). Incorporating blood urea nitrogen concentration, renal aortic resistance index, absolute peak time and cortical echo, the nomogram was constructed. The AUC of the predictive model was 0.814(95% CI=0.722-0.905) and the cutoff value was 0.67(corresponding to a total score of about 157 points). Both internal verification (AUC=0.788) and calibration curve demonstrated the clinical usefulness of the nomogram. Conclusions:The nomogram for predicting the occurrence of rejection in renal allograft patients based on multimodal ultrasound features and clinical data can guide the individualized treatment of patients with renal dysfunction.

2.
Journal of China Pharmaceutical University ; (6): 300-305, 2022.
Article in Chinese | WPRIM | ID: wpr-929467

ABSTRACT

@#In this paper, chemical derivatization-high performance liquid chromatography was used to determine the potential genotoxic impurities chloroacetyl chloride and chloroacetic acid, respectively, in the raw material of azintamide.Derivatization was carried out using 2-nitrophenylhydrazine followed by the determination.Separation was performed on a Thermo Syncronis C18 column (250 mm × 4.6 mm, 5 μm), with mobile phase consisting of 0.1% phosphoric acid in water (A) and acetonitrile(B) by gradient elution, at a flow rate of 1 mL/min.The column temperature was 40 °C and the detection wavelength was 226 nm.The blank solvent, derivatization reagent, and azintamide did not interfere with the peak of the test substance, and the target component was well separated from the others.For impurities chloroacetyl chloride and chloroacetic acid, the limits of detection (LOD) were 7.5 ng/mL and 15 ng/mL respectively. There was a good linear relationship between the integral area and the concentration in the range of 30-300 ng/mL.The sample recovery rate was in the range of 87.37% ~ 109.75%.The two methods established in this study have good specificity, good precision, high sensitivity and simple operation, which can be used for the trace determination of potential genotoxic impurities chloroacetyl chloride and chloroacetic acid in the raw material of azintamide.

3.
Chinese Critical Care Medicine ; (12): 635-639, 2022.
Article in Chinese | WPRIM | ID: wpr-956024

ABSTRACT

Objective:To explore the changes of intracranial pressure in intensive care unit (ICU) patients during the occurrence and evolution of delirium by using bedside ultrasound to measure the optic nerve sheath diameter (ONSD) to evaluate intracranial pressure.Methods:A retrospective observational study was conducted. Adult patients who developed delirium during hospitalization in the general ICU of Beihai People's Hospital from October 2020 to November 2021 were enrolled, and patients who did not have ultrasonographic ONSD records within 24 hours after the diagnosis of delirium were excluded. The ONSD measured before delirium was recorded as ONSD 0, the ONSD measured within 24 hours of the onset of delirium recorded as ONSD 1, and the ONSD reexamined after ONSD 1 recorded as ONSD 2. Patients were divided into intracranial hypertension group (ONSD 1 > 5 mm) and normal intracranial pressure group (ONSD 1 ≤ 5 mm) according to the size of ONSD 1. According to the outcome of delirium, the patients were divided into cured, improved, and non-improved groups. The reduction ratio of ONSD 2 to ONSD 1 in the three groups were calculated and compared. Pearson correlation test was used to analyze the correlation between fluid balance and ONSD changes after delirium. Results:There were 43 patients, including 40 cases in the intracranial hypertension group (the incidence rate was 93.0%), 3 cases in the normal intracranial pressure group, 23 cases were cured, 13 cases were improved, and 7 cases were not improved. In the intracranial hypertension group, 11 cases had ONSD 0 and ONSD 1 records, and ONSD 1 was significantly higher than ONSD 0 [mm: 5.88±0.61 vs. 5.34±0.57, 95% confidence interval (95% CI) -0.85 to -0.23, P = 0.003]. The reduction ratio of ONSD 2 to ONSD 1 in the cured group was significantly higher than that in the improved group and the non-improved group [(12.04±6.20)% vs. (5.68±4.10)%, (0.17±3.96)%; 95% CI were 2.37 to 10.33, 6.41 to 17.31, P values were 0.003 and 0.000, respectively]. The correlation analysis showed that the reduction ratio of ONSD 2 to ONSD 1 was negatively correlated with fluid balance ( r = -0.42, 95% CI was -0.66 to -0.10, P = 0.012). Conclusions:The incidence of intracranial hypertension in ICU delirium patients is high. A more pronounced decrease in intracranial pressure predicts a better delirium outcome. Dynamic ONSD measurement can provide valuable information for the prevention and treatment of delirium.

4.
Chinese Journal of Ultrasonography ; (12): 408-413, 2021.
Article in Chinese | WPRIM | ID: wpr-884339

ABSTRACT

Objective:To compare the diagnostic efficacy and ability of Thyroid Imaging Reporting Data System version (TI-RADS) of American College of Radiology (ACR) and artificial intelligence(AI) TI-RADS in diagnosis of thyroid nodules.Methods:A retrospective analysis was done on 266 patients(276 nodules) proved by ultrasound-guided fine-needle aspiration cytology (US-FNAC) in General Hospital of Eastern Theater Command from January to December 2019. The ROC curve of the two TI-RADS versions was drawn and the area under the curve (AUC) was calculated and compared.Results:AUCs of ACR TI-RADS and AI TI-RADS were 0.747 and 0.853. The sensitivity, specificity, positive predictive value and negative predictive value (96.62%, 62.50%, 74.87%, 94.12%) of AI TI-RADS were higher than ACR TI-RADS (95.27%, 44.53%, 66.51%, 89.06%). AI TI-RADS was able to avoid more unnecessary FNAC (71.74%) than ACR TI-RADS (67.03%).Conclusions:Both ACR TI-RADS and AI TI-RADS have good performances for differential diagnosis of thyroid nodules. AI TI-RADS is a more simple scoring system with better overall diagnostic performance and ability to exclude unnecessary FNAC with high negative predictive value than ACR TI-RADS.

5.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 220-225, 2017.
Article in Chinese | WPRIM | ID: wpr-641193

ABSTRACT

Objective To explore the qualitative evaluation of contrast-enhanced ultrasound (CEUS) in the differential diagnosis between benign and malignant thyroid nodules (TNs).Methods Totally 110 outpatients with 132 TNs underwent CEUS were enrolled in this study in Jinling Hospitall Medical School of Nanjing University (Nanjing General Hospital of Nanjing Military).Nanjing General Hospital of Nanjing Military All the nodules underwent ultrasound guided fine needle aspiration biopsy (FNAB).113 TNs were histologically diagnosed,the characteristics of enhancement for each noudle were scored.The characteristicsof enhancement between benign and malignant TNs were compared by chi-square test.The receiver operating characteristic (ROC) curve analysis were conducted to determine the diagnostic values of thyroid CEUS.Results Contrast-enhanced patterns were significantly different between benign and malignant TNs in the degree,homogeneity of enhancement,enhanced ring and boundary,shape and size of the enhanced lesions (x2=23.85,P < 0.001;x2=7.43,P=0.04;x2=34.54,P < 0.001;x2=25.7,P < 0.001;x2=53.10,P < 0.001;x2=22.78,P < 0.001;x2=30.90,P < 0.001).Contrast-enhanced patterns were not significantly different between benign and malignant TNs in the process and completeness of enhancement.Malignant lesions had concentric (79.5%),inhomogeneous (89.0%) and low (71.1%) enhanced with irregular (79.5%) and unclear (64.4%) boundary and bigger size (63.0%).The typical CEUS feature of benign nodules was peripheral ring hyperenhancement (34.7%).According to ROC curve,the cut off value was 3.5 points.The area under the ROC curve (AUC) for CEUS was 0.862 (95%CI:0.797-0.927).The sensitivity,specificity and accuracy for CEUS were 80.8%,79.6%,80.3% respectively.Conclusion The pattem of CEUS may assist in differential diagnosis of benign and malignant TNs.

6.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 903-908, 2017.
Article in Chinese | WPRIM | ID: wpr-712042

ABSTRACT

Objectives To investigate the diagnostic performance of the combination of ultrasound elastography and automated breast volume scanner (ABVS) in differentiation of benign and malignant breast imaging reporting and data system (BI-RADS) 4 breast lesions. Methods Data from 137 breast cancer patients (147 tumors) confirmed pathologically were analyzed. Each tumor was examined by ABVS and ultrasound elastography. All tumors were diagnosed as BI-RADS 4 by ABVS. With final pathology results as the gold standard, the predictive value in differentiating BI-RADS 4 breast lesions between ultrasound elastography and the combination of ultrasound elastography and ABVS were compared. Results There were 54 benign nodules and 93 malignant nodules in this study. The diagnostic sensitivity of ultrasound elastography and the combination of ultrasound elastography and ABVS were 94.6% and 98.9%,the specificity were 57.4% and 57.4%, the accuracy were 81.0% and 83.7%, the area under the curve were 0.858 and 0.965, respectively. The diagnostic performance of ultrasound elastography combined with ABVS was better than that of ultrasound elastography. Conclusions Ultrasound elastography have certain value in differential diagnosis of BI-RADS 4 breast lesions, especially when combining with ABVS, which will improve its diagnostic accuracy. Ultrasound elastography combined with ABVS can improve the detection rate of malignant lesions in BI-RADS 4 breast lesions and reduce the rate of preoperative biopsy, and it has a good application prospect.

7.
Journal of Regional Anatomy and Operative Surgery ; (6): 119-121, 2016.
Article in Chinese | WPRIM | ID: wpr-500083

ABSTRACT

Objective To investigate the effect of systematic health education on the ultrasound guided interventional therapy for pa -tients with cysts.Methods Totally 181 patients with cysts who received the ultrasound guided interventional therapy in our hospital ,were randomly divided into observation group and control group .The patients in the observation group received systematic health education ,while patients in control group received convention health education .Results The differences of pain score between two groups were statistical significance(P<0.05).By health education,the patients in the observation group had a deeper knowledge of the operation and became more cooperative(P<0.05).Conclusion Systematic health education could alleviate the pain and improve the psychological indisposition reac -tions of patients,and enhance therapeutic compliance of patients with ultrasound guided interventional therapy .In the meantime,systematic health education could improve the quality of work and enhance the diathesis of paramedic .

8.
Journal of Medical Postgraduates ; (12): 706-709, 2014.
Article in Chinese | WPRIM | ID: wpr-453320

ABSTRACT

Objective This study was to analyze the causes of the complications of ultrasound -guided percutaneous renal bi-opsy in children . Methods We retrospectively analyzed the complications of ultrasound-guided percutaneous renal biopsy in 236 children along with the age, sex, sample length, times of puncture, and types of disease of the patients .We used the binary Logistic regression model to analyze the influences of various factors on the post -biopsy complications . Results After renal biopsy , 22 (9.3%) of the patients experienced various degrees of but no severe complications .The incidence of complications was significantly correlated with the sample length (P<0.05), but not with the age, sex, sample length, times of puncture, and types of disease of the patients. Conclusion Ultrasound-guided percutaneous renal biopsy is an effective diagnostic method for children , with a high suc-cess rate and a low incidence of complications .And the incidence of complications can be reduced by improving the skills of puncturing and accuracy of ultrasound positioning .