Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Journal of the Korean Society of Coloproctology ; : 253-258, 2012.
Article in English | WPRIM | ID: wpr-67522

ABSTRACT

PURPOSE: Prostaglandin (PG) E2 is known to be closely related to cancer progression and is inactivated by 15-hydroxyprostaglandin dehydrogenase (PGDH). 15-PGDH is shown to have tumor suppressor activity and to be down-regulated in various cancers, including colorectal cancer (CRC). Therefore, we evaluated the expression of 15-PGDH and its prognostic effect in patients with CRC. METHODS: 15-PGDH expression was examined by using immunohistochemistry in 77 patients with CRC. Its prognostic significance was statistically evaluated. RESULTS: Negative 15-PGDH expression was noted in 55.8% of the 77 cases of CRC. 15-PGDH expression showed no correlation with any of the various clinicopathologic parameters. The status of lymph node metastasis, tumor-node-metastasis stages, and pre-operative carcinoembryonic antigen levels showed significant prognostic effect. However, univariate analysis revealed down-regulation of 15-PGDH not to be a predictor of poor survival. The 5-year overall survival rate was 71.7% in the group with positive expression of 15-PGDH and 67.1% in the group with negative expression of 15-PGDH, but this difference was not statistically significant (P = 0.751). CONCLUSION: 15-PGDH was down-regulated in 55.8% of the colorectal cancer patients. However, down-regulation of 15-PGDH showed no prognostic value in patients with CRC. Further larger scale or prospective studies are needed to clarify the prognostic effect of 15-PGDH down-regulation in patients with colorectal cancer.


Subject(s)
Humans , Carcinoembryonic Antigen , Colorectal Neoplasms , Down-Regulation , Hydroxyprostaglandin Dehydrogenases , Immunohistochemistry , Lymph Nodes , Neoplasm Metastasis , Oxidoreductases , Prognosis , Survival Rate
2.
Journal of the Korean Ophthalmological Society ; : 2521-2526, 2000.
Article in Korean | WPRIM | ID: wpr-222491

ABSTRACT

No Abstract Available.


Subject(s)
Blepharoptosis , Silicones
3.
Journal of the Korean Ophthalmological Society ; : 433-438, 2000.
Article in Korean | WPRIM | ID: wpr-35222

ABSTRACT

To evaluate the reproducibility in measuring the velocities of perifoveal hyperfluorescent dots, we analyzed fluorescein angiographs of 24 eyes[24 patients]which had central serous retinopathy. Fluorescein angiography was performed with a scanning laser ophthalmoscope[SLO, Rodenstock, Mnchen, Germany]Distances between 5 moving hyperfluorescent dots in a perifoveal capillary were measured at each consecutive frame[interval 1/30 sec]. And then velocities of 5 fluorescent dots were measured with image analysis program by converting the distances to real retinal size using the Littmann's curve in 20 eyes. In the other 4 eyes, the velocities between 5 fluorescent dots of each 2 to 4 capillaries were measured. Perifoveal capillary mean blood flow velocity and standard deviation were 2.08 +/-0.36 mm/sec, and mean coefficient of variation of the velocities measured in a vessel of one patient was 12.58%. However, reliability of the velocities of 2 to 4 capillaries on the 4 eyes was relatively low. In conclusion, the measurement of velocities between perifoveal fluorescent dots with scanning laser ophthalmoscope may be a reproducible method for a perifoveal capillary. However, reliability of measuring velocities was not sufficient enough to use the velocity of one perifoveal capillary as macular blood flow.


Subject(s)
Humans , Blood Flow Velocity , Capillaries , Central Serous Chorioretinopathy , Fluorescein Angiography , Fluorescein , Ophthalmoscopes , Retinaldehyde
4.
Journal of the Korean Ophthalmological Society ; : 1697-1703, 2000.
Article in Korean | WPRIM | ID: wpr-112404

ABSTRACT

To verify the accuracy and reproducibility of corneal thickness measurements obtained with Orbscan (Orbtek, Inc., Salt Lake City, USA), the measurements were compared with those taken with an ultrasound pachymeter (Omega Compuscan, Storz). Central corneal thickness was measured by each method in 100 eyes of 50healthy subjects. The averages by the two methods were compared. One examiner took the measurements twice by each method in 20 eyes of 10 subjects, and intraexaminer reproducibility was evaluated. Two examiners measured the thickness in 20 eyes of 10 subjects and interexaminer reproducibility was assessed. The average corneal thickness was 550.27+/-3.56 micrometer in the Orbscan measurements and 526.62+/-3.70 micrometer in the ultrasound pachymetry: There was a statistically significant difference between the two methods. Significant difference was noticed but this showed a constant corresponding correlation with the Orbscan showing a 4.4%lower average. The intraexaminer and interexaminer reproducibility showed high reliability(Guttman split-half point<0.99). The Orbscan pachymetry is a highly reliable method and may be widely used in clinical practice.


Subject(s)
Corneal Pachymetry , Lakes , Ultrasonics , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL