Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. bras. cardiol. invasiva ; 19(1): 78-83, mar. 2011.
Article in Portuguese | LILACS | ID: lil-591723

ABSTRACT

Introdução: A estenose da artéria do rim transplantado (EART) é a principal complicação vascular associada a eventos adversos em pacientes portadores de enxerto renal, cuja incidência varia de 1% a 23%. A arteriografia é o padrão de referência para o diagnóstico, possibilitando tratamento imediato; porém, em decorrência da anatomia variável e da localização da anastomose, muitas vezes são necessárias projeções adicionais, levando a maior exposição ao contraste e à radiação. A angiografia rotacional com reconstrução tridimensional (tridimensional rotational angiography – 3D-RA) surge como ferramenta para o diagnóstico e o tratamento da EART. O objetivo deste estudo foi avaliar a acurácia das medidas obtidas pela 3D-RA, comparativamente à obtida pela angiografia convencional. Métodos: De abril de 2010 a janeiro de 2011, foram realizadas 41 3D-RA em pacientes com alta suspeita clínica de EART. As imagens foram analisadas por observadores independentes, sendo as medidas da arteriografia convencional obtidas no momento do procedimento e as da 3D-RA, após o processamento das imagens pelo software Philips Allure 3D-RA. Resultados: Foram analisadas 35 3D-RA (84%) consideradas adequadas para a realização das medidas angiográficas, das quais 20% contribuíram com informações adicionais relevantes para a estratégia terapêutica. Não houve diferença estatisticamente significante entre as medidas dos diâmetros de referência e luminal mínimo da artéria obtidas pela 3D-RA e pela angiografia convencional, além de ter havido forte correlação entre elas. Conclusões: A 3D-RA surge como ferramenta útil para o diagnóstico da EART, encaao obter medidas acuradas, oferecer informações complementares e relevantes para o diagnóstico e tratamento, além de potencialmente reduzir o tempo do procedimento e a exposição ao contraste e à radiação.


Background: Transplant renal artery stenosis (TRAS) is the major vascular complication associated to adverse events in patients with kidney grafts, whose incidence ranges from1% to 23%. Angiography is the gold-standard for diagnosis, enabling immediate treatment; however, due to the variable anatomy and location of anastomosis, additional projectionsare often required, leading to greater exposure to contrast medium and radiation. Tridimensional rotational angiography (3D-RA) appears as a tool for diagnosis and treatment of TRAS. The aim of this paper was to evaluate the accuracy of measurements obtained by 3D-RA in comparison to conventionalangiography. Methods: From April, 2010 to January, 2011, 41 3D-RAs were performed in patients with clinicalsuspicion of TRAS. Images were analyzed by independent observers; conventional angiography measurements were obtained online and 3D-RA measurements were obtained offline with the Philips Allure 3D-RA software. Results: Thirty-five3D-RAs (84%) were considered adequate for angiographic measurements, and 20% provided additional and relevant information for the therapeutic strategy. There was no statistically significant difference between measurements obtainedfrom the reference diameter and minimal luminal diameter of the artery using 3D-RA and conventional angiography. In addition, there was a strong correlation between them.Conclusions: 3D-RA comes up as a useful tool for TRAS diagnosis, providing accurate measurements and complementary and relevant information for the diagnosis and treatment, in addition to potentially reducing procedure time and exposure to contrast and radiation.


Subject(s)
Humans , Male , Female , Adult , Renal Artery Obstruction/diagnosis , Renal Artery Obstruction , Kidney Transplantation , Angiography
2.
Arq. bras. cardiol ; 88(5): e115-e117, maio 2007. ilus
Article in Portuguese | LILACS | ID: lil-453060

ABSTRACT

Mulher com 61 anos de idade, portadora há 11 anos de prótese mecânica, foi internada com dispnéia súbita, palidez e fibrilação atrial. A avaliação diagnóstica incluiu ecocardiografia transesofágica, que demonstrou restrição importante da mobilidade de um dos folhetos da prótese mitral e imobilidade do outro, juntamente com imagem de espessamento compatível com trombo aderido à valva. Foi feito o diagnóstico de trombose de prótese mecânica mitral e instituída terapia trombolítica (rtPA) com sucesso. A paciente está em acompanhamento há mais de um ano, com evolução satisfatória.


A 61-year-old female patient using a mechanical prosthesis for 11 years was admitted to the hospital with sudden dyspnea, pallor and atrial fibrillation. The diagnostic evaluation included transesophageal echocardiogram, which showed a significantly reduced motion of one of the leaflets of the mitral prosthesis and immobility of the other, in addition to a thickened structure compatible with a thrombus adherent to the valve. The patient was diagnosed with thrombosis of mechanical mitral valve prosthesis. Thrombolytic therapy (rtPA) was started successfully. The patient has been followed up for more than one year with a favorable outcome.


Subject(s)
Female , Humans , Middle Aged , Heart Valve Prosthesis/adverse effects , Mitral Valve , Thrombosis/diagnosis , Acute Disease , Echocardiography, Transesophageal , Follow-Up Studies , Fibrinolytic Agents/therapeutic use , Thrombolytic Therapy , Treatment Outcome , Thrombosis/drug therapy , Thrombosis/etiology
SELECTION OF CITATIONS
SEARCH DETAIL