Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Article in English | IMSEAR | ID: sea-38699

ABSTRACT

The pharmacokinetic and relative bioavailability studies of 20-mg enalapril tablets, the test product manufactured by Biolab, Thailand compared to the reference product (Merck Sharp & Dohme, USA) was conducted in 14 healthy Thai male volunteers following a single dose, two-period, crossover design. Each subject received 20-mg enalapril tablets of both formulations with a 1-week washout period. Plasma samples collected over a 24-h period after administration were analyzed by LC/MS/MS. Pharmacokinetic parameters were determined by using non-compartmental analysis. Regarding bioequivalence testing, the 90 per cent confidence intervals of Cmax and AUC(0-infinity) ratios (test/reference) of enalapril were 101.8-134.9 per cent and 105.9-121.4 per cent and those of enalaprilat were 104.2-122.3 per cent and 104.5-118.1 per cent. Based on the European bioequivalence guideline, the 90 per cent confidence intervals of Cmax and AUC(0-infinity) ratios of both parent and metabolite forms were within the acceptable ranges of 70-143 per cent and 80-125 per cent, respectively. It was concluded that the test formulation was bioequivalent to the reference formulation and both formulations can be used interchangeably in clinical practice.


Subject(s)
Adolescent , Adult , Antihypertensive Agents/pharmacokinetics , Biological Availability , Cross-Over Studies , Enalapril/pharmacokinetics , Enalaprilat/pharmacokinetics , Humans , Male , Middle Aged , Volunteers
2.
Article in English | IMSEAR | ID: sea-45288

ABSTRACT

OBJECTIVES: To assess the average bioequivalence of two formulations of 8-mg ondansetron tablets--test product (Unison Laboratories, Thailand) and reference product (Glaxo Wellcome, USA)--in 14 healthy Thai male volunteers. MATERIAL AND METHOD: In a randomized, single dose, fasting, two-period, crossover study design with a 1-week washout period, each subject received an 8-mg ondansetron tablet. Serum samples were collected over a 24-hour period after administration. Subsequently serum concentrations of ondansetron were analyzed by using a validated HPLC-UV method. Pharmacokinetic parameters were determined by using non-compartmental analysis. RESULTS: No significant difference was observed in any of the pharmacokinetic parameters analyzed. The time to reach the maximal concentration (Tmax, hour), the peak concentration (Cmax, ng/ ml) and the area under the concentration-time curve (AUC(0-infinity), ng x h/ml) of ondansetron for reference and test preparations were 2.6 + 1.8 vs 2.2 + 0.6, 49.5 +/- 18.9 vs 48.5 +/- 13.7 and 352.2 +/- 184.7 vs 323.8 +/- 154.5, respectively. The 90 per cent confidence intervals for Test/Reference ratio of Cmax and AUC(0-infinity) were found within the bioequivalence range of 80-125 per cent (90.3-110.0% and 88.4-99.6%, respectively). CONCLUSION: The bioequivalence of these two ondansetron preparations was demonstrated.


Subject(s)
Administration, Oral , Adolescent , Adult , Antiemetics/administration & dosage , Humans , Male , Middle Aged , Ondansetron/administration & dosage , Reference Values , Tablets , Thailand , Therapeutic Equivalency
3.
Article in English | IMSEAR | ID: sea-41737

ABSTRACT

The bioequivalence study of 5-mg enalapril tablets, Enaril (Biolab, Thailand) compared to Renitec (Merck Sharp & Dohme, USA) was conducted in 14 healthy Thai male volunteers following a single dose, two-period, crossover design. Each subject received 4 tablets of 5-mg enalapril tablets of both formulations with a 1-week washout period. Plasma samples collected over a 24-hour period after administration were analyzed by LC/MS/MS. Pharmacokinetic parameters were determined by using non-compartmental analysis. Regarding bioequivalence testing, the 90 per cent confidence intervals of Cmax and AUC(0-infinity) ratios (Enaril/Renitec) of enalapril were 86.3-126.1 per cent and 93.0-118.5 per cent and those of enalaprilat were 86.4-124.1 per cent and 90.3-116.8 per cent. Based on the European bioequivalence guideline, the 90 per cent confidence interval of Cmax and AUC(0-infinity) ratios of both parent and metabolite forms were within acceptable ranges of 70-143 per cent and 80-125 per cent, respectively. It was concluded that Enaril 5 mg tablet was bioequivalent to Renitec 5 mg tablet.


Subject(s)
Adolescent , Adult , Angiotensin-Converting Enzyme Inhibitors/administration & dosage , Confidence Intervals , Cross-Over Studies , Enalapril/administration & dosage , Humans , Male , Middle Aged , Thailand , Therapeutic Equivalency
SELECTION OF CITATIONS
SEARCH DETAIL