Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Indian J Ophthalmol ; 2013 July; 61(7): 355-357
Article in English | IMSEAR | ID: sea-148213

ABSTRACT

Glaucoma drainage devices (GDDs) have been used in the management of complicated glaucomas. GDDs are associated with various complications such as tube migration, tube or plate exposure or extrusion, ocular motility disturbance and infection. Erosion of conjunctiva and exposure of the GDD remains a risk factor for the development of endophthalmitis. A wide range of materials have been used for this purpose, including sclera, dura, pericardium, fascia lata and cornea. However, there is no evidence to prove that any of these methods is superior to another for providing tectonic durability in the long term. In this report, we present a case of neovascular glaucoma, who developed conjunctival melting over the tube of an Ahmed Glaucoma Valve implant and was successfully managed with Cap Doxycycline.

2.
SJO-Saudi Journal of Ophthalmology. 2013; 27 (4): 287-290
in English | IMEMR | ID: emr-143022

ABSTRACT

A 65-year-old diabetic and hypertensive male presented with a sudden diminution of vision after sustaining a trivial fingernail injury to his only good-seeing [right] eye. The patient underwent phacotrabeculectomy with posterior chamber intraocular lens [PCIOL] implantation 22 years previously. In his right eye visual acuity at presentation was counting fingers at 1.5 m with an accurate projection of light. Intraocular pressure [IOP] was 4 mmHg. The anterior chamber was uniformly shallow with a peripheral iridocorneal touch. Angle details could not be visualized. The bleb was avascular, thin and cystic with a positive forced Seidel test. Fundus examination showed 360degree choroidal detachments. B-scan ultrasound revealed massive choroidals. Revision of dysfunctional filtering bleb by conjunctival advancement with bleb preservation and anterior chamber reformation with healon was performed. Postoperatively, the first day visual acuity improved to 6/36, the anterior chamber was deep, bleb was well covered with conjunctiva, the IOP was 10 mmHg and fundus examination revealed resolving choroidals. At the final follow up at 4 months, the patient did not require medication and visual acuity was 6/12, the bleb was functioning well with an IOP of 14 mmHg. Examination of the fundus revealed a cup-to-disc ratio of 0.5 with moderate non-proliferative diabetic retinopathy changes. The patient has been advised to maintain a strict glycemic control and return for routine follow up after 3 months.


Subject(s)
Humans , Male , Conjunctiva/surgery , Glaucoma/surgery , Postoperative Complications , Intraocular Pressure , Diabetic Retinopathy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL