Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 288-294, 2008.
Article in Chinese | WPRIM | ID: wpr-635165

ABSTRACT

Objective To evaluate the conventional ultrasound (US) and contrast-enhanced ultrasound (CEUS) in diagnosis of splenic trauma including its grading diagnosis. Methods US and CEUS in 42 patients with splenic trauma confirmed by CT and/or operation were performed during 9.2004-10.2007. All the data were compared and analyzed retrospectively. Results Of 42 patients with splenic trauma, 28 cases were detected and 14 cases were missed on US examination, whereas, 40 cases were detected and only 2 mild cases were missed on CEUS examination. The detection rate of lesions with CEUS was significantly higher than that of US (P<0.001) . Ten cases in grading the injury were underestimated by US, however, none of them were underestimated by CEUS. CEUS had good concordance with CT and/or operation in grading diagnosis of 42 cases except two mild cases. Conclusions CEUS has very good concordance with CT and/or operation in detecting injury and grading the splenic trauma compared with conventional US. CEUS as a new imaging technology has made great advance of ultrasoongraphy in evaluation of splenic trauma including injury grading,and it is very useful in clinical application.