Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 214-217, 2014.
Article in Chinese | WPRIM | ID: wpr-448008

ABSTRACT

Objective Three parameters include circumferential strain (CS),circumferential strain rate (CSr) and stiffness parameter (β) were measured to evaluate the elasticity of carotid artery using two-dimensional(2D) strain imaging and evaluate its clinical value in patients with type 2 diabetes mellitus (T2DM).Methods 60 patients with T2DM were collected and divided into carotid intima-midia thickness (CIMT) thickeness group(34 cases,1.0 mm<CIMT≤1.2 mm) and plaque group(26 case,CIMT> 1.2 mm).33 normal people were supplied as control group.The systolic global peak CS and CSr of the carotid artery were obtained from short-axis view of the common carotid artery and the stiffness parameters β was measured using 2D strain imaging.All the parameters were compared among the three groups.Results The CS and CSr were decreased and β was increased in patients with T2DM (P < 0.01),The CS and CSr obtained from the plaque group were less than that of the CIMT thickeness group(P <0.05),but the β was higher than that of the CIMT thickeness group (P <0.01).The CS and β were correlated significantly with CIMT respectively (r =-0.79,P < 0.01 ; r =0.72,P < 0.01).Conclusions 2D strain imaging is a technique for early assessing the carotid artery elasticity in patients with T2DM,the thicker the CIMT is,the smaller the deformation is and the larger the β is.

2.
Journal of Chinese Physician ; (12): 468-472, 2012.
Article in Chinese | WPRIM | ID: wpr-425946

ABSTRACT

ObjectiveTo evaluate the diagnostic value of multi-slice CT (MSCT) and multi-dimensional reconstructions for congenital pulmonary stenosis (PS) in children.MethodsThe enhanced thin CT images of 33 patients with PS were retrospectively analyzed,the data was transmitted to the workstation for multi-planar reformation ( MPR),volume rendering technique (VRT) and maximum intensity projection (MIP).The CT imaging features of PS were analyzed combining with operation resul ts and Ultrasonic Cardiogram (UCG).ResultsIn 33 cases of PS,there were 17 cases with pulmonary valve stenosis (PVS),10 cases with right ventricular infundibulum stenosis (RVIS),and 6 cases with pulmonary trunk stenosis (PTS).The first two were correctly diagnosed by UCG,5 cases of PVS and Icases of RVIS were correctly diagnosed by MSCTA,the later was correctly diagnosed by UCG and MSCTA.In 14 cases with collateral circulations between aorta and pulmonary artery ( APC ),all were correctly diagnosed by MSCTA,only 3 case was diagnosed by UCG,1 case was misdiagnosed as PDA.UCG can clearly demonstrate the others intra-cardiac deformities,such as ASD,VSD,RVH,PFO,SV,DORV,TECD and TBD,the accuracy rate of MSCTA was 39.4%,and MSCTA can clearly demonstrate the origin,course and diameter of extracardiac vascular abnormalities,such as PDA,RAA,TGA,TAPVD,CoA,PLSV and VLSA,the accuracy rate of UCG was 697%.ConclusionsMSCT and multi-dimensional reconstruction were a kind of non-invasive method,it was a good approach for extra-cardiac vascular malformations and APC in PS.Combining with UCG,it can further be used to improve the diagnostic accuracy of intra-cardiac malformation and supply diagnostic evidence for clinical treatment.

SELECTION OF CITATIONS
SEARCH DETAIL