Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Journal of Southern Medical University ; (12): 1444-1448, 2016.
Article in Chinese | WPRIM | ID: wpr-256579

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate the effect of the length of covered stents in the portal and hepatic veins on long-term clinical efficacy of transjugular intrahepatic portosystemic shunt (TIPS).</p><p><b>METHODS</b>We retrospectively reviewed 53 cases receiving TIPSs between January, 2008 and December, 2011. All the shunts were created with Fluency stents (8 mm in diameter). Bare metal grafts of the same diameter were implanted to extend the length in the portal and hepatic veins as deemed necessary according to angiographic images. The primary patency, hepatic encephalopathy and patient survival were evaluated during the follow up. The length of the covered stents within the hepatic vein (X1) and in the portal vein (X2), and the total length of stents placed in the hepatic vein (X3) and the portal vein (X4) were measured and their effects on primary patency and the patients'outcomes were evaluated.</p><p><b>RESULTS</b>The procedures were completed successfully in all the patients and the mean portosystemic pressure decreased from 29.80∓4.83 mmHg to 19.00∓3.92 mmHg (t=13.44, P<0.01) after the procedure. The patients were followed up for a median of 64 months (3 to 89 months, 39 months on average). Hepatic encephalopathy occurred in 23% (12/53) of the patients after TIPS. Shunt dysfunction occurred in 16 cases, and the cumulative primary patency rates at 1 to 5 years were 83%, 75%, 63%, 62%, and 54%, respectively. The cumulative survival rates of the patients at 1 to 5 years were 79%, 72%, 72%, 69%, and 69%, respectively. Cox proportional regression analysis showed a significant association between the length of covered-stent in the hepatic vein and the primary patency (OR=0.42, P<0.01), and there was a significant association between the length of stent in the portal vein and the patient survival. No significant correlation was found between these parameters and hepatic encephalopathy.</p><p><b>CONCLUSION</b>Increasing the length of the covered stent in the hepatic vein and decreasing the stent length in the portal vein can improve the primary patency and the patient survival receiving TIPS.</p>


Subject(s)
Humans , Angiography , Hepatic Encephalopathy , Hepatic Veins , General Surgery , Portal Vein , General Surgery , Portasystemic Shunt, Transjugular Intrahepatic , Retrospective Studies , Stents , Survival Rate , Treatment Outcome
2.
Journal of Southern Medical University ; (12): 294-296, 2016.
Article in Chinese | WPRIM | ID: wpr-264052

ABSTRACT

We here report 3 cases successfully treated with transjugular intrahepatic portosystemic shunt using Viatorr stent. The 3 patients were had a diagnosis of liver cirrhosis with portal vein hypertension, and presented with black stool and hematemesis. After the treatment, the patients' portal vein pressures were decreased without black stool or hematemesis. Our success demonstrate the feasibility of using Viatorr stent in transjugular intrahepatic portosystemic shunt.


Subject(s)
Humans , Hypertension, Portal , General Surgery , Liver Cirrhosis , General Surgery , Portal Vein , Portasystemic Shunt, Transjugular Intrahepatic , Stents
3.
Journal of Southern Medical University ; (12): 2504-2509, 2009.
Article in Chinese | WPRIM | ID: wpr-325078

ABSTRACT

<p><b>OBJECTIVE</b>To summarize our 10-year experience with percutaneous fluoroscopically guided removal (PFGR) of metallic foreign body (MFB) in the soft tissue.</p><p><b>METHODS</b>PFGR was performed in 65 patients for removing a total of 368 MFBs from the soft tissues. The MFBs ranged from 0.2 to 0.3 cm in length embedded in the soft tissue for 7 days to 8 years. For superficial MFBs, the MFBs were removed directly with curved forceps under real time fluoroscopy. For deep MFBs, trocar technique was applied using the instruments for percutaneous diskectomy, with the outer cannula inserted toward the foreign body under real-time fluoroscopy followed by MFB removal by grasping forceps.</p><p><b>RESULTS</b>A total of 346 MFBs were successfully removed without any serious complications (success rate 94.0%), including 154 removed directly and 192 MFBs with trocal technique. The time of the procedures and radiation exposure for MFB removal was 30 s to 20 min and 1-6 min, respectively.</p><p><b>CONCLUSION</b>PGFR of MFBs in the soft tissue under fluoroscope is safe and effective. Direct removal using curved forceps is suitable for MFBs in superficial soft tissues, while trocal techniques needs to be utilized for deep MFBs.</p>


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Young Adult , Fluoroscopy , Methods , Foreign Bodies , Diagnostic Imaging , General Surgery , Lower Extremity , Metals , Radiography, Interventional
4.
Journal of Southern Medical University ; (12): 293-295, 2008.
Article in Chinese | WPRIM | ID: wpr-293392

ABSTRACT

<p><b>OBJECTIVE</b>To assess value of endovascular graft exclusion (EVGE) with digital subtraction angiography (DSA) in the treatment of Stanford type B aortic dissection (AD).</p><p><b>METHODS</b>On the basis of diagnosis with multi-slice spiral CT (MSCT), DSA was performed in 20 Stanford B AD cases for further diagnostic confirmation and EVGE was conducted for treatment. The DSA findings of the cases and the therapeutic effect of EVGE were evaluated.</p><p><b>RESULTS</b>In the 20 cases of Stanford type B AD, altogether 22 stents were implanted during EVGF with a stent release success rate of 100%. Postoperative examination revealed no obvious leakage or false lumen in 15 cases, and death occurred in 1 case 6 days after the operation due to right renal hemorrhage and infection, and the rest 19 patients were cured and discharged. Follow-up of the patients demonstrated improvement in the clinical symptoms, and MSCT showed that all the dissections were sealed successfully. No severe complications were observed 3 months after the treatment in these patients.</p><p><b>CONCLUSION</b>DSA can identify the fine anatomy of AD and allowed intraoperative monitoring in EVGE, which is an effective and safe means for treatment of Stanford type B AD.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Aortic Dissection , Diagnostic Imaging , General Surgery , Angiography, Digital Subtraction , Methods , Aortic Aneurysm , Diagnostic Imaging , General Surgery , Blood Vessel Prosthesis Implantation , Methods , Follow-Up Studies , Stents , Tomography, Spiral Computed , Treatment Outcome
5.
Journal of Southern Medical University ; (12): 384-386, 2007.
Article in Chinese | WPRIM | ID: wpr-268127

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate the feasibility of no antibiotic administration to prevent infection during the perioperative period of percutaneous intradiscal ozone-injection for treatment of lumbar disc herniation.</p><p><b>METHODS</b>Seventy-two patients with lumbar disc herniation but normal body temperature as well as normal results of three routine tests (blood, urine, stool) and C-reactive protein (CRP) level were randomly divided into two groups. The patients in prophylaxis group were given cephalothin V(2.0 g) intravenous 30 min before the operation, and the control group did not use any antibiotics. All the patients were injected with 6-10 ml ozone (40 microg/ml) for medical use into the discs with 21G needles under fluoroscopic guidance, followed by 10 ml ozone into the paravertebral space. Three days later the general examinations and CRP measurement were repeated.</p><p><b>RESULTS</b>No infection was found in these patients, nor were any significant differences noted in the results of the examinations between the two groups after controlling in patients with above-normal white blood cell count, neutrophil percentage and CRP level.</p><p><b>CONCLUSION</b>Prophylaxis antibiotics is not necessary during the perioperative period of percutaneous intradiscal ozone injection for lumbar disc herniation.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Anti-Bacterial Agents , Therapeutic Uses , Cefazolin , Therapeutic Uses , Drug Therapy, Combination , Injections, Intralesional , Intervertebral Disc Displacement , Diagnostic Imaging , Drug Therapy , Lumbar Vertebrae , Oxygen , Ozone , Perioperative Care , Radiography
6.
Acta Pharmaceutica Sinica ; (12): 108-114, 2006.
Article in Chinese | WPRIM | ID: wpr-253490

ABSTRACT

<p><b>AIM</b>To design and synthesize new phenyloxyisobutyric acid analogues as antidiabetic compounds.</p><p><b>METHODS</b>Eight new target compounds were synthesized by combination of lipophilic moieties and acidic moiety with nucleophilic replacement or Mitsunobu condensation. The eight compounds were confirmed by 1H NMR, 13C NMR, IR and MS.</p><p><b>RESULTS</b>In vitro insulin-sensitizing activity (3T3-L1 adipocyte) demonstrated, that the cultured glucose concentration of up-clear solution detected with GOD-POD assay were 5.942, 6.339, 6.226 and 6.512 mmol x L(-1), respectively, when rosiglitazone, pioglitazone, compounds A and B were added to the insulin-resistant system.</p><p><b>CONCLUSION</b>In vitro insulin-sensitizing activity of target compound A is in between that of rosiglitazone and pioglitazone, and activity of target compound B is slightly less than that of pioglitazone.</p>


Subject(s)
Animals , Mice , 3T3-L1 Cells , Adipocytes , Butyrates , Chemistry , Pharmacology , Hypoglycemic Agents , Chemistry , Pharmacology , Insulin , Pharmacology , Molecular Structure , PPAR gamma , Pharmacology
7.
Chinese Journal of Radiology ; (12)1999.
Article in Chinese | WPRIM | ID: wpr-680102

ABSTRACT

5 mm and ≤8 mm in 4 cases.The mean value was 4.2 mm. Four patients noticed reduction in their vision and two had diplopia.Those patients were examined by CT or MR.Direct venography was performed in each patient.After the diagnosis of OVM was confirmed, intralesional injection of BLE was performed.The efficacy of the treatment and complications were observed during the following 8 to 42 months(mean 23 months).Results The BLE were successfully injected in all the patients.All patients had resolution of proptosis and diplopia.Three patients gained improvement of visual acuity.The periorbital swelling occurred in all patients after operation and resolved within 1 week without special treatment.Other complications,such as orbital hemorrhage and periorbital scar,were not observed during following-up.Conclusion Intralesional injection with BLE is convenient,safe and efficient for the treatment of OVM.

SELECTION OF CITATIONS
SEARCH DETAIL