1.
Chinese Journal of Radiology ; (12): 756-761, 2023.
Article in Chinese | WPRIM | ID: wpr-993003

ABSTRACT

Objective:To investigate the feasibility of simultaneous arteriovenous enhancement of neck CT with two-stage injection of contrast agent and its effect on image quality and radiation dose.Methods:A total of 30 patients undergoing neck CT enhancement scan due to space-occupying lesions in Beijing Tongren Hospital, Capital Medical University from February to April 2022 were prospectively included as the experimental group. The neck CT enhancement scan was performed with two-stage injection of contrast agent and arteriovenous simultaneous enhancement. The dosage of contrast agent was calculated according to the patient′s body weight, and the method of two-stage injection was adopted. The dosage of contrast agent in the first stage was 0.7 ml/kg, with normal saline in the middle stage, and the second stage (began at 35 s) was 0.3 ml/kg. A total of 30 patients with gender and age matching with the experimental group from December 2021 to January 2022 were retrospectively collected as the control group. The control group was treated with the traditional arterial phase and venous phase scanning method with the dosage of 1.0 ml/kg contrast agent. The arterial phase was scanned at the 30 s and the venous phase was scanned at the 60 s. The CT values of bilateral carotid arteries and jugular veins in the experimental group were measured, the CT values of bilateral carotid arteries in the arterial phase were measured in the control group, and the CT values of bilateral carotid arteries and jugular veins in the venous phase were measured. Carotid artery enhancement score was performed for images of experimental group and control group in arterial and venous phase, and jugular vein and lesion enhancement score was performed for images of experimental group and control group in venous phase. The effective dose was calculated for both groups. The difference of carotid artery CT values between images was compared by one-way analysis of variance, and LSD method was used for pairwise comparison. The CT values of jugular vein were compared using independent sample t test. Kruskal-Wallis test was used to compare carotid artery enhancement scores, and Nemenyi method was used for pairwise comparison. Jugular vein and lesion enhancement scores and effective dose were compared by Mann-Whitney U test. Results:The CT value of carotid artery of experimental group [left (276±24) HU, right (273±25) HU] was lower than that of control group in arterial phase [left (329±33) HU, right (327±32) HU], and higher than that in the venous phase [left (147±15) HU, right (148±16) HU]. All the differences were statistically significant ( P<0.001). The CT value of jugular vein of experimental group [left (206±18) HU, right (203±19)] was higher than that of control group in the venous phase [left (154±15) HU, right (151±15)], the difference was statistically significant ( t=11.88, 11.76, both P<0.001). There was no significant difference in carotid artery enhancement score between experimental group and control group in arterial phase ( P=0.624), but the carotid artery enhancement score of the experimental group was higher than that of the control group in the venous phase, and the difference was statistically significant ( P<0.001). The scores of jugular vein and lesion enhancement in experimental group were higher than those of control group in venous phase, and the difference was statistically significant ( Z=5.01, P<0.001). The effective dose of the experimental group [2.41(2.04, 2.72) mSv] was decreased by 52.2% compared with the control group [5.04(4.18, 5.44) mSv], and the difference was statistically significant ( Z=-6.24, P<0.001). Conclusions:The neck CT enhanced scan with two-stage injection of contrast agent and arteriovenous simultaneous enhancement method can obtain comprehensive images of arterial and venous phases, and realize simultaneous enhancement of carotid artery, jugular vein and lesions, and reduce radiation dose.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 212-216, 2021.
Article in Chinese | WPRIM | ID: wpr-884501

ABSTRACT

Objective:To investigate the feasibility of the application of low tube potential scanning in dacryocystography CT.Methods:The mixture of iohexol and saline with the ration of 1∶3 as the dacryocyst was set on the nose wing of the head-neck phantom. The phantom was scanned at 80, 100, 120, 140 kV with appropriate mAs to set the volume CT dose index(CTDI vol)at 10, 15, 20, 25, 30, 35 or 40 mGy. All the images were objectively evaluated to find out the optimal scanning parameters of 80 kV/240 mAs with the same contrast-to-noise ratio(CNR)of conventional scanning condition of 120 kV/180 mAs. A total of 62 patients who conducted dacryocystography CT in Beijing Tongren Hospital from November 2019 to July 2020 were prospectively selected. They were randomly divided equally into conventional scanning group with 120 kV/180 mAs and low tube potential group with 80 kV/240 mAs. The CT number, noise (SD) and contrast-to-noise ratio (CNR) of the two groups were measured as the objective evaluation indicators of image quality. The subjective evaluation was performed by two senior radiologists using a double-blind method and a 5-scale system evaluation. Results:For the phantom study, the CNR was positively correlated with CTDI vol under the same tube potential ( r=0.985, 0.965, 0.971, 0.972, P < 0.05). With the same CNR, the radiation dose decreased with lower tube potential. Under the conventional scanning parameters of 120 kV/180 mAs, the CNR was 27.8. At the same CNR, the optimal scanning parameters were 80 kV/240 mAs. For the clinical study, the CTDI vol of conventional scanning group and low tube potential group were 31.2 and 12.8 mGy respectively, 59% decreased in low tube potential group. There were statistically significant differences in CT number of dacryocyst area, CT number of orbital fat area and noise between the two groups ( t=-3.476, 2.601, -5.704, P < 0.05). There was no statistically significante difference in CNR between 2 groups( P>0.05). Two observers had a good consistency ( Kappa >0.75). There was no statistically significante difference in subjective rating between 2 groups( P>0.05). Conclusions:Low tube potential scanning could obtain satisfactory image quality in dacryocystography CT at much lower radiation dose.

3.
Chinese Journal of Medical Education Research ; (12): 1151-1153, 2020.
Article in Chinese | WPRIM | ID: wpr-865981

ABSTRACT

We strive to explore a student-centered evaluation system focused on improving students' learning efficiency and learning effect. Through classroom questioning, discussion of difficult cases, new progress report, question bank test, writing of clerkship notes, simulated inquiry between students with bedside inquiry, physical examination between students with bedside physical examination, operation training of basic clinical skills, direct observation and evaluation of clinical skills, mini-clinical exercise evaluation, graduation examination and other measures, an evaluation system for promoting learning by class evaluation, clerkship evaluation and practice evaluation has been established to cultivate the connotation construction of medical moral quality and clinical practice ability of medical students, and further promote the mastery of basic theoretical knowledge and clinical operation skills. By comparing the results of the phased examination for medical practitioners, the passing rate of 2018 is significantly higher than that of 2017, with 23.31% increased passing rate of theoretical results, and 0.79% increased passing rate of skills operation results. It can be seen that the evaluation system for promoting learning has played a guiding role in the teaching practice of clinical courses in our hospital.

4.
Chinese Journal of Medical Imaging Technology ; (12): 767-770, 2010.
Article in Chinese | WPRIM | ID: wpr-474261

ABSTRACT

The function of the retina is sensitive to oxygen tension, and any changes in oxygen perfusion associated with retinal vessel diseases, such as diabetic retinopathy could affect inner retinal oxygen responses (ΔPO_2). However, the application of currently available techniques in measurements of the retinal oxygenation is limited. Recently, with the development of MRI, it is possible to detect ΔPO_2 noninvasively, and the effects are satisfactory. The application of MR based measurements of ΔPO_2 following the shift from breathing room air were reviewed in this article.