1.
Chinese Journal of Radiation Oncology ; (6): 161-164, 2014.
Article in Chinese | WPRIM | ID: wpr-443252

ABSTRACT

Objective To study the image quality control system to ensure that equipment meet clinical needs.Methods It was scanning the Catphan504 phantom with models of high quality head,standard dose head and pelvis,we could get the results of CT numbers linearity,uniformity,spatial resolution,contrast resolution.Using T test to compare different scanning technique results.Results The standard dose head scanning technique was better than the pelvis scanning technique in CT numbers linearity test,and gets the best result in uniformity test.The result of CT numbers uniformity was higher in the standard dose head scanning than the high quality head and the pelvis scanning (9.7 ±3.9 vs.17.9 ±5.3,P =0.00 and 9.5 ± 4.0 vs.31.1 ± 5.7,P =0.00).The result of contrast resolution was higher in the pelvis scanning than the high quality head and the pelvis scanning (5.6 ± 0.1 vs.1.3 ± 0.5,P =0.00 and 6.0 ± 1.0 vs.1.3 ± 0.5,P =0.00).The result of spatial linear distance was very accurate,the range was 4.98 -5.06 cm.Conclusions The results of spatial linearity test are stable and accuracy,but CT numbers linearity and uniformity test are affected by the scanning technique significantly for device.To spatial resolution test and contrast resolution test,we need to set the standard and tolerance according to each linear accelerator specialty.

2.
Chinese Journal of Radiation Oncology ; (6): 560-562, 2012.
Article in Chinese | WPRIM | ID: wpr-430129

ABSTRACT

Objective Performing a daily quality assure (QA) program to get variation and error range of on board imager (OBI) system,so that the OBI system can meet the needs of clinical treatment.Methods The daily QA program including: mechanical accuracy,2D/2D Shift calculations accuracy,couch motion accuracy.Results The max deviation was-0.7 mm in lcft-right (LR) dircction and 0.8 mm in superior-inferior (S1) direction in Linac& OBI isocenter accuracy check.The max deviations in 4 blades (x1,x2,y2,y1) position accuracy check were:-2.1 mm,2.2 mm,± 1.7 mm,-2.1 mm.In OBI mechanical arms position accuracy check,31% standard data was 85.2 cm with 0 mm deviation; 69% standard data was 85.1 cm with 1 mm deviation.In LR,SI and anterior-posterior direction,2D/2D shift calculations accuracy was 0.46 mm,1.35 mm,-0.04 mm and couch motion accuracy was-0.1 mm,0.3 mm,0.2 mm,respectively.Conclusions By performing the daily QA program,it could be found whether OBI works properly and satisfies the clinical use.The physicist can pay more attention to the parameters which change frequently,and adjust the frequency of the parameters which are stable,so that working efficiently.

3.
Chinese Journal of Radiation Oncology ; (6): 258-261, 2012.
Article in Chinese | WPRIM | ID: wpr-425845

ABSTRACT

ObjectiveTo investigate the anatomical changes and dose variation of rectum during radiotherapy in patients with cervical cancer.Methods Ten patients with cervical cancer underwent intensity-modulated radiotherapy using online cone beam computed tomography (CBCT) before each fraction.Rectum was contoured on each CBCT and projected onto the planning CT to analyze the changes of the rectal volume and position.The rectal volume receiving ≥ 45 Gy ( V45 ) was evaluated accordingly.Results227 CBCT images in 10 patients were collected.The rectal volume changed from ( 35.0 ± 7.3)cm3 to (97.7±14.7) cm3.The shift of rectal center was (0.14 ±0.06) cm in left and right direction,(0.24±0.10) cm in anterior and posterior direction,and (0.55±0.28) cm in superior and inferior direction.The V45 of rectum varied from (9.19±2.46)% to (60.54 ±11.67)%.In7 of the 10 patients,rectal volume and V45 of the rectum had significant positive correlation (r =0.582 - 0.743,all P < 0.01 ).Among the 227 images,the V45 of rectum was ≤50% in 68 images (30.0% ).ConclusionsSignificant changes in rectal volume and position occurred during fractionated radiotherapy in patients with cervical cancer,which resuhs in variations in the dose rectum received.For most patients,rectal volume and the V45of rectum had significant positive correlation.

4.
Chinese Journal of Radiation Oncology ; (6): 218-221, 2011.
Article in Chinese | WPRIM | ID: wpr-415536

ABSTRACT

Objective To investigate bladder anatomical changes and dose variation in patients with cervical cancer.Methods We analyzed 20 patients,undergoing external beam radiotherapy scanning cone beam CT(CBCT)before each fraction.Bladder was contoured on each CBCT,was projected onto the planning CT and assesses anatomical changes and dose variation.Results A total 451 CBCT images,for 20 patients were collected for analysis,show more change in bladder volume and position.In 15 cases bladder volume and V45 had no significant correlation(r=0.225 -0.473,all P>0.05),4 cases shows negative correlation(r=-0.564,P<0.05;r=-0.597,P<0.01;r=-0.942,P<0.01;r=-0.816,P<0.01),1 case shows positive correlation(r=0.662,P<0.01).Have more than the criteria(V45≤50%)number is 64/451(14.2%)in whole treatment.Conclusions For most patients by filling adequacy bladder,bladder dose variation is acceptable:CTV lager for individual patients should be closely observed its regression,implementation of the offline or online calibration.