Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Tissue Engineering Research ; (53): 232-234, 2005.
Article in Chinese | WPRIM | ID: wpr-407775

ABSTRACT

BACKGROUND: Angiostatin(AS) can effectively inhibit proliferation and migration of vascular endothelial cells and also inhibit tumor angiogenesis.OBJECTIVE: To observe the inhibitory action of angiostatin, 131I and 131 I labeled angiostatin(131I-AS) on proliferation of human umbilical vein endothelial cell ECV304 and on mass and volume of Lewis lung carcinoma (LLC) in mice.DESIGN: A randomized controlled trial with human umbilical vein endothelial cell ECV304 and Lewis lung carcinoma tumors growing in C57BL/6 mice as subjects of research.SETTING: A radiological lab and a nuclear medicine department in a military university.MATERIALS: Totally 28 LLC carrying male C57BL/6 mice, weighing(20± 2) g, 5 - 7 weeks old.METHODS: 131I-AS solutions of four concentrations were made: solution A(131I 0. 74 GBq/L, AS 0. 5 mg/L); solution B(131I 0.74 GBq/L, AS 16 mg/L); solution C(131I 1.48 GBq/L, AS 0.5 mg/L); solution D(131I 1.48 GBq/L, AS 16 mg/L). The effect of 131I-AS, AS alone and 131I alone on proliferation of human umbilical vein endothelial cell ECV304 was observed with MTT method. The 28 tumor carrying mice were randomly assigned into 4 groups, in each of which was injected 0.3 mL of 131I AS(131I 11.1 MBq and AS 2.5 mg/kg), AS(2.5 mg/kg), 131I(11.1MBq) and saline respectively for twice with 7 days interval. Then the change in tumor mass and volume was observed.MAIN OUTCOME MEASURES: ① The inhibition rate on cell proliferation with MTT method; ② Change in tumor mass and volume.RESULTS: ① The inhibition rate of AS alone(0. 5 -64 mg/L) on ECV304 was (7.3 ± 3.5) % - (41.9 ± 4. 3 )% ( P = 0. 003 vs AS of 0). The inhibition rate of the 4 concentrations of 131I-AS on ECV304 was(23.9±2.8)% ,(58.2±3.9)%, (39. 1 ±4. 1)% and(78.4 ±5.4)%, which were much higher than AS alone or 131I alone( P =0. 000 3) . ② The mean volume of LLC in the four groups were (3 943 ± 236), (5 219 ± 351 ), ( 1 963 ± 126),(7 353 ±350) mm3 respectively. Compared with saline group, the tumor inhibiton rate in the other 3 groups were 46.4% , 29.0% , 73.3% respectively( P =0. 000 1 ).CONCLUSION: 131I-AS inhibits proliferation of endothelial cells in vitro and inhibits LLC growth in vivo and it outdoes AS or 131I alone.

2.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-592351

ABSTRACT

20ng/ml.The total three-year survival rate is 87%(33/35).Conclusion The effect and prognosis of ?-knife on prostate cancer treatment can be evaluated by the value of PSA before and after the treatment.

3.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-595849

ABSTRACT

Objective To assess and compare the advantages and disadvantages of five fields of three dimensional conformal radiation therapy(3DCRT),three fields of 3DCRT and the simulator-guided radiation therapy for patients with esophageal carcinoma.Methods Twenty patients with esophageal carcinoma were treated by three dimensional conformal radiation therapy,at the same TPS,three Dimensional conformal radiation therapy target and normal tissue of three radiotherapies were simulated.The treatment planning was five days per week with 1.8~2.0 Gy per fraction。 5 fractions per week,5OGy per 5~6 weeks. Results Compared with simulator-guided radiation therapy,3DCRT planning has better dose distribution and protection of normal tissue. Conclusion Esophageal cancer conformal radiotherapy can reduce the radiation injury of the normal tissue and complications,and improve treatment of conformal radiotherapy and the target dose distribution.

4.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-593563

ABSTRACT

Objective To investigate precision error between Varian auri-point localization system and Tosplane digital-bed localization system. Methods Varian Eclipse localization method and Topslane localization method were used separately to locate one target area for one same patient. Then deviations on the tumor center coordinate were measured under the simu- lation localization machine. Results Under two localization methods, the length error: 1.7mm ?0.3mm; the width error: 0.5mm?0.4mm; the altitude error: 1.2mm?0.4mm. Conclusion The curative effect of radiotherapy would be improved by applying the Topslane localization bed to the Varian Eclipse plan system.

5.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-591098

ABSTRACT

Objective To investigate the probability of verifying the X-knife treatment plan by the radiotherapy simulator,and to analyze and report the errors of the X-knife treatment plan for reference.Methods The radiation fields of the X-knife treatment plan were observed in the whole simulating treatment process by the radiotherapy simulator.Results The error rate of X-knife treatment plan were in the simulating treatment process was 5.9%(22/372).Among the errors,3 cases of X-knife plans were found in the simulating treatment process,and the errors of isocenter in Z direction were 10cm.Conclusion This is a special error of X-knife TPS,which deserves more attention in stereotactic radiotherapy.

SELECTION OF CITATIONS
SEARCH DETAIL