Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add filters








Language
Year range
1.
Journal of International Oncology ; (12): 241-245, 2016.
Article in Chinese | WPRIM | ID: wpr-493134

ABSTRACT

Objective To analyze the effects of curcumin combined with cisplatin on the growth and lymphatic metastasis of cervical cancer xenografts in nude mice.Methods The human cervical carcinoma Caski cells xenotransplanted tumor models were established.Inoculated mice were randomly divided into 4 groups according to random number table:control (normal saline 10 ml/kg),Cur (curcumin 100 mg/kg),Cis (cisplatin 3 mg/kg) and Cur + Cis group (100 mg/kg curcumin +3 mg/kg cisplatin).The tumor volume and anti-tumor rate were calculated.The mRNA levels of macrophage migration inhibitory factor (MIF) and vascular endothelial growth factor-C (VEGF-C) were analyzed by real-time fluorescent quantitative polymerase chain reaction (PCR).Results The inhibitory rates of Cur group,Cis group and Cur + Cis group were 40.8%,53.3% and 60.0%.After 15 days treatment,the tumor volumes of the control group,Cur group,Cis group and Cur + Cis group were (123.44 ± 35.62),(71.72 ± 28.36),(65.47 ± 18.32),(53.44 ± 10.79) mm3.The growth rates of tumor volume in Cur group,Cis group and Cur + Cis group were slower,Cur + Cis group could more effectively inhibit tumor volume growth.The difference among the four groups had statistically significance (F =16.890,P =0.000).Real-time fluorescent quantitative PCR detection showed that compared with the control group (1.000),the MIF mRNA expressions in Cur group,Cis group and Cur + Cis group were 0.322 ±0.094,0.154 ± 0.006 and 0.136 ± 0.007,VEGF-C mRNA expressions in the three groups were 0.312 ± 0.068,0.263 ± 0.072 and 0.221 ± 0.041.The differences among groups had statistically significance (F =220.279,P =0.000;F =143.250,P =0.000).MIF mRNA was positively related with VEGF-C mRNA (r =0.815,P =0.001).Conclusion Curcumin combined with cisplatin can inhibit the growth of Carski cell xenografts in nude mice.Through the down-regulating expression of MIF mRNA and VEGF-C mRNA,cisplatin and curcumin can inhibit the lymphatic metastasis of cervical cancer,and it may be one of the important mechanisms of its anti-tumor effects.

2.
International Journal of Biomedical Engineering ; (6): 46-49, 2012.
Article in Chinese | WPRIM | ID: wpr-424851

ABSTRACT

ObjectiveAn input system was designed to solve the current problems of slow creation of electronic health record caused by the difficulty of resident information input.MethodsThe system,based on the Android platform,was designed to collect and save information by using PDA devices,and to send the information to the remote receiver over the wireless network with the hybrid encryption of DES and RSA.The receiver saved the information into the relational database after decryption.ResultsThe system saved acquisition time greatly compared to the traditional method.The transmission speed,security and reception rate of the system could well satisfy the requirements of information collection.ConclusionThe system provides a better way to solving the problems of heavy workload,low efficiency and high error rate in information collection,and will play an important role in practical life.

3.
International Journal of Biomedical Engineering ; (6): 348-352, 2011.
Article in Chinese | WPRIM | ID: wpr-417552

ABSTRACT

Objective According to the lack of timeliness in the current domestic disease notification system,an effective solution is proposed to solve the problem.Methods Based on research and analysis of the health information exchange standards HL7 (Health Level 7),which is widely used in the world,a solution on the base of HL7 standards is proposed in this study,to store,transfer,analyze and publish data.Results The solution allows medical institutions and the centers for disease control connect seamlessly,ensuring the data transfer in time,and publishing the data through Web service.Conclusion The solution can keep the people abreast of the latest status of the epidemic,and do their own protection as well as promote social stability.

4.
Chinese Journal of Tissue Engineering Research ; (53)2007.
Article in Chinese | WPRIM | ID: wpr-595378

ABSTRACT

A kind of saliva glucose detector based on electrochemistry is designed to measure the saliva glucose of diabetes mellitus, so as to achieve non-invasive measurement for diabetes mellitus state. A Prussian blue modified glassy carbon electrode was designed as the working electrode of the three-electrode system to improve the electrode sensitivity to H2O2's electrochemical reaction in a lower voltage. A three-electrode system was employed for measuring the current generated by the oxidation-reduction reaction of glucose catalyzed by glucose oxidase. Technique of shield-driving was used to avoid the attenuation of the voltage when it was processed, so as to ensure the precision measurement. A single chip microcomputer, C8051F020, was used to control the system and provide scanning voltage for the electrode, make A/D transition and process the result. Then the outputs were displayed on liquid crystal display. This detector's operating voltage was 0.496 V. The sensitivity was 0.1 mmol/L. There was a constant of proportionality between the measuring results of this detector and the precise analysator, Lanbiao LK98B. Results of the study show that this detector has low operating voltage, high sensitivity and good function of whole system, and can meet the request of measure.

5.
Chinese Journal of Tissue Engineering Research ; (53)2007.
Article in Chinese | WPRIM | ID: wpr-593246

ABSTRACT

AIM:To design a signal collecting system of urethral internal pressure based on embedded microprocessor(ARM).METHODS:Based on ARM,the signal collecting module of urethral internal pressure and signal amplifier circuit were designed with sensor technology.The A/D transition circuit was improved by signal feedback theory to increase measurement accuracy.The software of sensor temperature drift was rectified by second linear interpolation so to enhance the accuracy of data collection.RESULTS:In simulated static urethral internal pressure collection,the signals of urethral internal pressure that sensor collected were corresponded with the location completely and send them into RAM of ARM for following analysis.CONCLUSION:The ARM-based signal collecting system of urethral internal pressure has simple circuit,reliability,lower power consumption,high precision and strong spot data analysis.

6.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-589853

ABSTRACT

Objective To realize excellent remote medical treatment for patients.Methods The ECG monitoring module based on Bluetooth technology was designed.The ECG module and Bluetooth radio-frequency module,which possessed the function of data acquisition and simple processing,were connected through data wire to act as ECG terminal.By using C8051F020 and ROK 101 007 Bluetooth module,ECG Bluetooth transmission module read in HCI command through serial port,thus realizing mutual communication.VC++6.0 was used as developing tool to edit remote monitoring server programme running on the computers in monitoring center.Results ECG monitoring module could acquire ECG data in real time and transmit it to personal computers,and then send it to the monitoring center through Wide Band.In this way,real-time information exchange between doctors and users was realized.Conclusion This module makes full use of the advantages of Bluetooth technology and has strong practicability.

7.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-587511

ABSTRACT

With the development of digital hospital construction,the concept of digital hospital has been accepted by lots of hospitals.All sorts of medical information purely facing to medical affairs and its integrated research have become more and more important.Digital management of medical service in hospital has been one of the important field in hospital management,so it has brought a new research orientation on application in the communication standard of medical service.

8.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-589011

ABSTRACT

The conventional invasive tissue blood oxygen content measurement is poor in continuity.The weakness of the signal,strong interference and random transmission of the photon in tissues make the measurement difficult.Recently,near infrared spectrum technology has been applied to tissue blood oxygen content measurement.This paper presents a hardware design method for tissue blood oxygen content measurement by near infrared spectrum technology.

9.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-584648

ABSTRACT

Based on the development requirements of medical model, This paper introduces the capacity, features and application to portable medical instrument of USB (universal serial bus). The developing trend of USB is also discussed.

SELECTION OF CITATIONS
SEARCH DETAIL