Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Braz. dent. j ; 34(6): 67-74, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528033

ABSTRACT

Abstract This study aimed to evaluate the influence of dental adhesive color on the chromatic stability and fluorescence intensity of composite resin restorations of different thicknesses. Ninety bovine enamel samples were obtained and restored with resin composite varying thicknesses of restorative material and enamel (1.0 mm enamel and 1.0 mm composite; 1.5 mm enamel and 0.5 mm composite; 0.5 mm enamel and 1.5 mm composite). The restorations were made of composite resin (Opallis E-bleach H) using different types of dental adhesives: Ambar, Ambar APS, and Single Bond Universal (n=10). The samples were subjected to color measurement tests in a spectrophotometer using CIEDE2000 and fluorescence intensity measurements before and after aging in a red wine coloring solution. Data were subjected to analysis of variance (ANOVA) and Tukey's test (α = 0.05). There were no statistically significant changes in color stability or fluorescence intensity for restorations made of different materials or thicknesses (p>0.05). Single Bond Universal showed greater color stability at 0.5 mm thickness (ΔE00 = 4.4 ± 1.6) compared to other thicknesses of the same material (p=0.003), as well as a greater difference in fluorescence intensity after aging at 1.5 mm thickness (-414.9 ± 103.8) compared to other materials (p=0.0002). Overall, it was concluded that the different adhesive systems did not influence the color stability and fluorescence of restorations of different thicknesses.


Resumo O objetivo deste estudo foi avaliar a influência da cor do adesivo dental na estabilidade cromática e intensidade de fluorescência das restaurações de resina composta de diferentes espessuras. Foram obtidos noventa amostras de esmalte bovino que foram restaurados com resina composta, variando a espessura do material restaurador e do esmalte (1,0 mm de esmalte e 1,0 mm de compósito; 1,5 mm de esmalte e 0,5 mm de compósito; 0,5 mm de esmalte e 1,5 mm de compósito). As restaurações foram feitas de resina composta (Opallis E-bleach H) utilizando diferentes tipos de adesivos odontológicos: Ambar, Ambar APS, e Single Bond Universal (n=10). As amostras foram submetidas a testes de medição de cor em um espectrofotômetro usando CIEDE2000 e medições de intensidade de fluorescência antes e depois do envelhecimento em uma solução de coloração de vinho tinto. Os dados foram submetidos à análise de variância (ANOVA) e ao teste de Tukey (α = 0,05). Não houve mudanças estatisticamente significativas na estabilidade da cor ou intensidade de fluorescência para restaurações feitas de diferentes materiais ou espessuras (p>0,05). O Single Bond Universal mostrou maior estabilidade de cor a 0,5 mm de espessura (ΔE00 = 4,4 ± 1,6) em comparação com outras espessuras do mesmo material (p=0,03), bem como uma maior diferença na intensidade de fluorescência após o envelhecimento a 1,5 mm de espessura (-414,9 ± 103,8) em comparação com outros materiais (p=0,0002). Em geral, concluiu-se que os diferentes sistemas adesivos não influenciaram a estabilidade de cor e a intensidade de fluorescência das restaurações de diferentes espessuras.

2.
Araçatuba; s.n; 2022. 54 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1435699

ABSTRACT

O objetivo desse trabalho foi avaliar a influência de diferentes graus de opacidade e espessuras do dissilicato de lítio no grau de conversão de dois cimentos resinosos e na resistência de união dos mesmos à cerâmica. Duzentos e quarenta amostras cerâmicas de dissilicato de lítio (6x6 mm) foram obtidos a partir de blocos de IPS E-max CAD (Ivoclar Vivadent, Schaan, Liechtensten), nas opacidades HT (alta translucidez), LT (baixa translucidez) e MO (média opacidade), nas espessuras de 0,3 mm, 0,7 mm, 1,2mm, 1,7 mm, 2,0 mm. Para as análises do grau de conversão (n=9) e resistência de união (n=8) foram utilizados um cimento de ativação física (Variolink Esthetic LC) e um cimento dual (Multilink N). Para análise do grau de conversão, as amostras de cimento foram fotoativadas sob as amostras de cerâmica e levadas a um espectrômetro Raman confocal. Para o teste de resistência de união foram confeccionados cilindros de cimento resinoso sobre as amostras cerâmicas e submetidos ao ensaio de microcisalhamento. Os resultados mostraram que o aumento das espessuras causou diminuição no grau de conversão dos dois cimentos em todas as condições estudadas, porém só influenciou negativamente a resistência de união do cimento Variolink Esthetic LC quando unido à cerâmica na opacidade MO. Na comparação entre as opacidades, de maneira geral, a cerâmica de maior translucidez HT apresentou maiores valores de grau de conversão em comparação às outras opacidades. Já para resistência de união, em algumas espessuras as cerâmicas LT e MO apresentaram os maiores valores. O cimento dual Multilink N apresentou os maiores valores nas duas análises comparado ao cimento fotoativado Variolink Esthetic LC. Portanto, o aumento da espessura e da opacidade do material cerâmico podem promover uma diminuição no grau de conversão do cimento. A resistência de união também sofre uma diminuição com o aumento da espessura de cerâmicas mais opacas. No entanto, a maior translucidez do material não garante valores mais altos dessa mesma propriedade(AU)


This research aims to evaluate the influence of different degrees of opacity and thicknesses of lithium disilicate on the degree of conversion of two resin cements and on their bond strength to the ceramic. Two hundred and forty lithium disilicate ceramic samples (6x6 mm) were obtained from IPS E-max CAD (Ivoclar Vivadent, Schaan, Liechtensten), in HT, LT and MO opacities, with thicknesses of 0.3 mm, 0.7 mm, 1.2 mm, 1.7 mm, 2.0 mm. For degree of conversion (n=9) and bond strength analysis (n=8) a light cured (Variolink Esthetic LC) and a dual cured resin cement (Multilink N) were used. To analyze the degree of conversion, the cement samples were light cured under the ceramic samples and taken to a confocal Raman spectrometer. For the bond strength test, resin cement cylinders were made on the ceramic samples that were later subjected to a microshear. The results showed that the increase in thickness caused a decrease on degree of conversion of both cements in all the conditions studied, but it only had an influence on bond strength of Variolink LC cement for MO ceramic. Comparing the opacities, for the degree of conversion, the most translucent ceramics had higher conversion values compared to the less translucent ones in some thicknesses. As for bond strength, in some thicknesses the LT and MO ceramics showed the highest values. The dual cement Multilink showed the highest values of conversion degree and bond strength compared to Variolink Esthetic LC light-cured cement. The Multilink dual cement showed the highest values in both analyzes compared to the Variolink LC light-cured cement. Therefore, increasing the thickness and opacity of the ceramic material can promote a decrease in the degree of cement conversion. The bond strength also suffers a decrease with increasing thickness of more opaque ceramics and the greater translucency of the material does not guarantee higher values of this same property(AU)


Subject(s)
Resin Cements , Dental Porcelain , Ceramics , Dental Materials , Polymerization
3.
J. health sci. (Londrina) ; 23(1): https://revista.pgsskroton.com/index.php/JHealthSci/article/view/7199, 20210330.
Article in English | LILACS-Express | LILACS | ID: biblio-1179416

ABSTRACT

The purpose of this study was to evaluate a physical property (surface roughness) and a mechanical property (microhardness) of four type IV gypsum. 40 specimens were prepared from a metal matrix that reproduced an edentate upper alveolar ridge. They were divided into 4 groups (n = 10 Clone (G3), Durone(G4), SSWhite (G2), Asfer (G1) and submitted to roughness and microhardness tests . The obtained data were submitted to statistical analysis. By the Kolmogorov-Smirnov test it was verified that there was non-parametric distribution of the samples. The non-parametric Kruskal-Wallis and Mann-Whitney-U tests were applied in hardness and roughness data. In microhardness group 3(Clone) presented the best values (103.0 HV). In surface roughness (Ra), group 3(Clone) and Group 2 (SSWhite) showed the lowest values (1.8 µm) and all evaluated groups presented higher values than those found in metallic matrix (baseline). It was concluded that gypsum models obtained from molds with irreversible hydrocolloid are rougher than molded surface, regardless of the commercial brand. The samples made with the Clone gypsum (G3) have the highest microhardness.(AU)


O objetivo desse trabalho foi avaliar uma propriedade física (rugosidade superficial) e uma propriedade mecânica (microdureza) de quatro marcas comerciais de gesso tipo IV. Foram confeccionados 40 corpos de prova a partir de uma matriz metálica que reproduzia um rebordo alveolar superior edentado. Os mesmos foram divididos em 4 grupos (n=10), de acordo com as marcas comerciais (Clone, Durone, SSWhite, Asfer), e submetidos aos testes de rugosidade e microdureza superficial utilizando um rugosímetro e um microdurômetro respectivamente. Os dados obtidos foram computados e submetidos à análise estatística. Pelo teste de Kolmogorov-Smirnov verificou-se que não houve distribuição Normal das amostras. Dessa forma foram aplicados os testes não paramétricos de Kruskal-Wallis e Mann Whitney-U em ambas as análises. Na microdureza, a marca comercial Clone apresentou os melhores valores (103,0). Já na rugosidade superficial as marcas comerciais Clone e SSWhite apresentaram os menores valores (1,8). Ainda em relação à rugosidade superficial, as marcas comerciais avaliadas apresentaram valores maiores que os encontrados na matriz metálica. Concluiu-se que modelos em gesso obtidos a partir de moldes com hidrocolóide irreversível apresentam-se mais rugosos que a superfície moldada, independente da marca comercial avaliada. Os modelos em gesso confeccionados com a marca Clone apresentam melhor microdureza superficial. (AU)

4.
Prosthes. Lab. Sci ; 5(20): 78-84, jul.-set. 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-859397

ABSTRACT

Restaurações diretas com resina composta em dentes posteriores são ótimas opções devido à sua longevidade e estética agradável. Porém, em virtude da evolução dos materiais dentários, assim como das técnicas e algumas limitações das restaurações diretas, os procedimentos indiretos acabaram adquirindo mais espaço no mercado. As cerâmicas são utilizadas na confecção de restaurações indiretas e conferem ao paciente boas condições estéticas e funcionais por possibilitar contornos e contatos proximais excelentes, adaptação marginal satisfatória, resistência ao desgaste e a fratura e estabilidade de cor. O objetivo deste trabalho foi relatar um caso clínico envolvendo o elemento 16, com restauração de amalgama fraturada, que foi substituída por uma restauração indireta do tipo Inlay confeccionada por meio do sistema e.max Press. Primeiramente foi realizada a remoção de toda a restauração de amalgama e o preparo coronário para restauração tipo Inlay. Após a moldagem e obtenção do modelo de trabalho, realizou-se o enceramento, o qual foi incluído em revestimento e posteriormente foi submetido ao processo de injeção e prensagem da cerâmica, obtendo-se a restauração do tipo Inlay. Na sequência, foram efetuadas a prova e a cimentação da restauração, seguido de ajuste oclusal. Considerando o caso clínico apresentado, pode-se concluir que restaurações indiretas em cerâmica são boas opções para se utilizar em cavidades extensas em elementos posteriores. Entretanto, o cirurgião-dentista deve ter o conhecimento a respeito das propriedades físicas e mecânicas da cerâmica injetada, dos princípios biomecânicos do preparo e também sobre os sistemas adesivos a serem utilizados.


Direct composite resin restorations in posterior teeth are excellent options due to its longevity and satisfactory aesthetics. however, due to the evolution of dental materials and techniques, as well as some limitations of direct restorations, indirect procedures eventually gained more space. Ceramics are used in indirect restorations and give the patient good aesthetic and functional conditions for enabling contours and excellent proximal contacts, satisfactory marginal adaptation, resistance to wear and fracture as well as color stability. The aim of this study was to report a clinical case involving the element 16 with a fractured amalgam restoration replaced by an indirect inlay restoration made through Emax Press System. Removal of the amalgam restoration and coronary preparation for an inlay restoration type were performed. After impression and obtaining a working model, the wax-up was performed, invested, and subjected to ceramic pressing. Then it was performed a test and the cementation of restoration folowed by occlusal adjustment. Considering the presented clinical case, it can be concluded that indirect ceramic restorations are a good alternative to be used in large cavities in posterior elements. however, the professional must have the knowledge on the physical and mechanical properties of the ceramic material, the biomechanical principles of preparation, and also about adhesives systems to be used.


Subject(s)
Humans , Female , Biocompatible Materials , Ceramics , Dental Materials , Esthetics, Dental , Inlays
SELECTION OF CITATIONS
SEARCH DETAIL