Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 89-93, 2020.
Article in Chinese | WPRIM | ID: wpr-871581

ABSTRACT

Objective:To discuss whether balloon atrial septostomy(BAS) can provide safe and effective left ventricular venting for venoarterial extracorporeal membrane oxygenation(V-A ECMO).Methods:From March 2017 to January 2019, 9 patients received BAS for left ventricular venting during V-A ECMO treatment in our hospital, including 5 males and 4 females, aged 12-72 years. There were 3 cases of severe myocarditis, 4 cases of low cardiac output after cardiac surgery, and 2 cases of acute myocardial infarction. Basic data, procedure data, outcome and follow-up were recorded.Results:BAS were successfully performed in 9 patients. Procedure time on average was 42.2 min. Anterior mediastinal hematoma occurred in 1 case. There were no other procedure-related complications in the rest cases. No pulmonary edema or thrombosis occurred in all 9 cases during ECMO. No closure procedure was performed.Conclusion:BAS is a safe and effective method for left ventricular venting. The procedure is conductive to the recovery of patients with severe left heart failure.

2.
Chinese Journal of Interventional Cardiology ; (4): 617-620, 2014.
Article in Chinese | WPRIM | ID: wpr-459518

ABSTRACT

Objective To summarize the clinical effects of one stop hybrid approach for treating the tetralogy of fallot complicated with aorta pulmonary collateral arteries. Methods From Janu 2008 to June 2013, 79 cases of tetralogy of fallot were complicated with aorta pulmonary collateral arteries with mean age (5.4±3.9) years and weight (18.2±5.7) kg. All patients were diagnosed by echocardiography examination and accepted 64-row CT for demonstration of no dysplasia in pulmonary ressels, McGoon index was (1.7±0.6) and Nakata index was (176.7±7.3). 76 cases had aorta pulmonary collateral arteries for preliminary screening, and accepted cardiovascular angiography before operation. 3 cases were misdiagnosed before surgery and were confirmed by cardiovascular angiography after operation. Results There were 4 deceased cases with an operative mortality of 5.1%. 1 case died of lung infection and 3 cases died of refractory heart failure. In all aorta pulmonary collateral arteries, the smallest diameter was 2.5 mm, the largest was 9.4 mm, average (5.3±2.1) mm. 2 to 21 coils were implanted in respective case with an average of 10.2 coils per case. The maximum number of coils implanted in 1 single ressel was 9. The average number of ressels occluded was 3.7 (range from 1 to 11 ressels) in each case. One case received second closure due to re-open of collateral arteries on neo-vasculanigation. 14 cases had lung infection and 3 cases had pulmonary edema post operation. 75 cases were followed up for 3-72 months. 4 cases with post operative heart function of NYHA gradeⅢtoⅣand all other cases with gradeⅡon higher. Conclusions Peri-operative hybrid management for aorta-pulmonary collateral arteries can increase the operative success rates and reduce complications.

SELECTION OF CITATIONS
SEARCH DETAIL