Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
3.
Maghreb Medical. 1994; (278): 14
in French | IMEMR | ID: emr-33243
5.
Tunisie Medicale [La]. 1994; 72 (6-7): 420-5
in French | IMEMR | ID: emr-35855

ABSTRACT

18 cases of patients aged more than 15 years affected with non coected tetralgie of Fallot are reported. The average age is 20 years with au extreme of 15 and 37 years, 10 patients are females and 8 are males. All patients present a cyanosie in calm time 4 have signs of night heart insuficiency, 5 present syncorpss and 4 present hemoptysie. A right arricular hypertophy in 8 cases, and 3 intra-ventricular conduction are notreced during electrocardiogram. In heart catheterism the regleet auriculum premoir is of 6 mmHg, the ventricular telediaastolic pression is 11 mmHg. 3 patients hrad a palliative intervention. we notrced only one death. The immediate consequences are marpred by intra ventricular condiction in 11 cases, 2 regressive BAV and 5 heart insufficiency. 15 patients were controlled after 6 years, 14 have a normal life. These goods remits propose to surge all adults hairing tetralogie of Fallot but a complet reparaation in the early enfance


Subject(s)
Humans , Heart Defects, Congenital , Heart
6.
Tunisie Medicale [La]. 1993; 71 (12): 559-66
in French | IMEMR | ID: emr-31177

ABSTRACT

This study present 80 cases of operated aortic insufficiency. The rhumatismal etiology was the important [62.75%] middle age was 31 +/- 16.5 years. For 74 patients, we practice a substitute aortic valvular by a mechanical prothesis and for 6 cases by a bio-prothesis. The early death was in 7.5%. the later death was in 11.3%. the study of the preoperatory prognosis factors had shown the role of the age in the cardiac insufficency in the dilatation of the left ventricular and its dysfunction aprreciated echocardiography


Subject(s)
Humans , Thoracic Surgery/standards , Biological Evolution , Echocardiography
7.
Tunisie Medicale [La]. 1993; 71 (6-7): 299-304
in French | IMEMR | ID: emr-31226

ABSTRACT

The authors present the hemo dynamic performance of 31 prothesis aortic of saint- JUde by echo- doppler examination realised 48 months after this prothesis implantation. It was 6 prothesis N° 19, 12 prothesis N° 21 6 prothesis N° 6 and 7 prothesis N°25. Independenly of the size of the aortic Saint- Jude the maximal quickness trans prothetic is 2.59 +/- 0.35 m/s the maximal gradient is 26.95 +/- 2.3 mm hg. The transprothetic functional surface is 1.3 +/- 0.21 cm[2] and the indicative of permeability is 0.386 +/- 0.09. it was not a significative difference between the prothesis of small diameter and big diameter for the maximal quickness and the maximal gradient, the mitral surface is 1.2 +/- 0.2 cm[2] for the Saint- Jude n° = 19 and 1.53 +/- 0.3 cm[2] for the Saint jude n°25


Subject(s)
Humans , Aortic Valve , Echocardiography, Doppler , Heart Valve Diseases , Heart Valves
10.
Maghreb Medical. 1991; (245): 18-24
in French | IMEMR | ID: emr-20776
SELECTION OF CITATIONS
SEARCH DETAIL