1.
Rev. bras. anestesiol ; 66(2): 215-218, Mar.-Apr. 2016. graf
Article in English | LILACS | ID: lil-777409

ABSTRACT

ABSTRACT The anesthetic management of patients with large mediastinal masses can be complicated due to the pressure effects of the mass on the airway or major vessels. We present the successful anesthetic management of a 64-year-old female with a large mediastinal mass that encroached on the great vessels and compressed the trachea. A tracheal stent was placed to relieve the tracheal compression under general anesthesia. Spontaneous ventilation was maintained during the perioperative period with the use of a classic laryngeal mask airway. We discuss the utility of laryngeal mask airway for anesthetic management of tracheal stenting in patients with mediastinal masses.


RESUMO O manejo anestésico de pacientes com grandes massas situadas no mediastino pode ser complicado por causa dos efeitos da pressão da massa sobre as vias aéreas ou grandes vasos. Relatamos o manejo anestésico bem-sucedido de uma paciente de 64 anos com uma grande massa mediastinal que invadiu os grandes vasos e comprimiu a traqueia. Um stent traqueal foi colocado para aliviar a compressão da traqueia, sob anestesia geral. A ventilação espontânea foi mantida durante o período perioperatório com o uso de uma máscara laríngea clássica. Discutimos a utilidade da máscara laríngea para o manejo da colocação de stent traqueal em pacientes com massas situadas no mediastino.


Subject(s)
Humans , Female , Tracheal Stenosis/surgery , Stents , Anesthesia, General/methods , Mediastinal Neoplasms/complications , Tracheal Stenosis/etiology , Laryngeal Masks , Mediastinal Neoplasms/pathology , Middle Aged
2.
Rev. bras. anestesiol ; 64(6): 443-445, Nov-Dec/2014. graf
Article in English | LILACS | ID: lil-728856

ABSTRACT

Pulmonary artery catheter is an invasive monitor usually placed in high-risk cardiac surgical patients to optimize the cardiac functions. We present this case of blood oozing from the oximetry connection port of the pulmonary artery catheter that resulted in the inability to monitor continuous cardiac output requiring replacement of the catheter. The cause of this abnormal bleeding was later confirmed to be due to a manufacturing defect.


O cateter de artéria pulmonar é um monitor invasivo geralmente usado durante cirurgias cardíacas em pacientes de alto risco para aprimorar as funções cardíacas. Apresen-tamos o caso de escoamento de sangue pela porta de conexão do cateter de artéria pulmonar para oximetria que resultou na impossibilidade de monitorar o débito cardíaco contínuo e na substituição do cateter. A causa do sangramento anormal foi posteriormente confirmada como um defeito de fabricação.


El catéter de arteria pulmonar es un monitor invasivo generalmente usado durante cirugías cardíacas en pacientes de alto riesgo para optimizar las funciones cardíacas. Presen-tamos el caso de entrada de sangre por el puerto de conexión del catéter de arteria pulmonar para oximetría, trayendo como resultado la imposibilidad de monitorizar el gasto cardíaco continuo y, por ende, la sustitución del catéter. La causa del sangrado anormal fue posteriormente confirmada como un defecto de fabricación.


Subject(s)
Humans , Male , Middle Aged , Thoracic Surgery/instrumentation , Oximetry/methods , Cardiac Catheters/supply & distribution , Hemorrhage