Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Language
Year range
1.
Radiol. bras ; 54(4): 238-242, July-Aug. 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1287751

ABSTRACT

Abstract Objective: The objective of this study was to allow physicians with self-diagnosed gadolinium deposition disease symptoms to report their own experience. Materials and Methods: Nine physicians (seven females), with a mean age of 50.5 ± 8.3 years, participated in this case series. Nationalities were American (n = 6), British, Portuguese, and Romanian. Medical practices included internal medicine (n = 2), trauma surgery, ophthalmology, gastroenterology, psychiatry, family medicine, obstetrics/gynecology, and general practice. Results: Genetically, eight of the physicians were of central European origin. Underlying autoimmune conditions were present in four. Symptoms developed after a single injection in one physician and after multiple injections in eight. The precipitating agent was gadobenate dimeglumine in four physicians, gadobutrol in three, gadoterate meglumine in one, and gadopentetate dimeglumine in one. The most consistent symptoms were a burning sensation, brain fog, fatigue, distal paresthesia, fasciculations, headache, and insomnia. Eight of the physicians were compelled to change their practice of medicine. Conclusion: In the various physicians, gadolinium deposition disease showed common features and had a substantial impact on daily activity. Physicians are educated reporters on disease, so their personal descriptions should spark interest in further research.


Resumo Objetivo: O objetivo deste estudo foi possibilitar que médicos com sintomas de doença de deposição de gadolínio autodiagnosticada relatassem sua própria experiência. Materiais e Métodos: Nove médicos (sete mulheres), com média de idade de 50,5 ± 8,3 anos, participaram desta série de casos. As nacionalidades foram americana (n = 6), britânica, portuguesa e romena. As práticas médicas incluíram medicina interna (n = 2), traumatologia, oftalmologia, gastroenterologia, psiquiatria, medicina de família, ginecologia/obstetrícia e clínica geral. Resultados: Geneticamente, oito dos médicos tinham origem europeia central. Condições autoimunes subjacentes estavam presentes em quatro médicos. Os sintomas se desenvolveram após uma única injeção em um médico e após várias injeções em oito. O agente precipitante foi gadobenato dimeglumina em quatro médicos, gadobutrol em três, gadoterato meglumina em um e gadopentetato dimeglumina em um. Os sintomas mais consistentes foram sensação de queimação, confusão mental, fadiga, parestesia distal, fasciculações, cefaleia e insônia. Oito dos médicos foram forçados a alterar a sua prática médica. Conclusão: Em vários médicos, a doença de deposição de gadolínio mostrou características comuns e teve um impacto substancial na atividade diária. Os médicos são repórteres treinados sobre doenças, assim, suas descrições pessoais devem despertar interesse em pesquisas futuras.

2.
Radiol. bras ; 53(4): 229-235, July-Aug. 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136088

ABSTRACT

Abstract Objective: To evaluate the accuracy of steady-state free precession (SSFP) unenhanced magnetic resonance angiography (MRA) at 1.5 T for the identification of multiple renal arteries, using computed tomography angiography (CTA) as the reference standard. Materials and Methods: This was a prospective study involving 39 patients (26 males; mean age, 62.6 years) who underwent CTA and unenhanced MRA to evaluate the proximal and middle segments of the renal arteries. The analysis was performed in two phases: the quality of unenhanced MRA images was classified as diagnostic or nondiagnostic for the presence of multiple renal arteries by two independent readers; two other independent readers then evaluated the images previously classified as being of diagnostic quality. The sensitivity, specificity, and overall accuracy of unenhanced MRA were calculated, CTA being used as the reference standard. The kappa statistic was used in order to calculate interobserver agreement. Results: The image quality of unenhanced MRA was considered diagnostic in 70-90% of the extrarenal arterial segments. The CTA examination revealed 19 multiple renal arteries (8 on the right and 11 on the left). The accuracy of unenhanced MRA for the identification of multiple renal arteries was greater than 90%, with a sensitivity of 72.7-100% and a specificity of 96.3-100%. Conclusion: Unenhanced MRA provides high quality imaging of the extrarenal segments of renal arteries. This method may be used as an alternative for the evaluation of the renal arteries, given that it has an accuracy comparable to that of CTA.


Resumo Objetivo: Avaliar, prospectivamente, a acurácia da angiografia por ressonância magnética (angio-RM) sem contraste, com a sequência steady-state free precession (SSFP) 1,5 T, para a identificação de artérias renais múltiplas, usando para isso a angiografia por tomografia computadorizada (angio-TC) como padrão de referência. Materiais e Métodos: Trinta e nove pacientes (26 do sexo masculino; idade média de 62,6 anos) foram submetidos a angio-TC e angio-RM para avaliação dos segmentos proximais e médios das artérias renais. A análise dividiu-se em duas partes: inicialmente, a qualidade das imagens de angio-RM foi classificada como diagnóstica ou não diagnóstica por dois avaliadores independentes; posteriormente, outros dois avaliadores analisaram as imagens consideradas diagnósticas quanto à presença de múltiplas artérias renais. Sensibilidade, especificidade e acurácia da angio-RM foram calculadas utilizando-se a angio-TC como referência. Estatística kappa foi utilizada para cálculo da concordância interobservador. Resultados: A qualidade das imagens de angio-RM foi considerada diagnóstica em 70-90% dos segmentos arteriais extrarrenais. A angio-TC revelou 19 artérias renais múltiplas (8 direitas e 11 esquerdas). A acurácia da angio-RM para identificação de artérias renais múltiplas foi maior que 90%, com sensibilidade variando de 72,7% a 100% e especificidade variando de 96,3% a 100%. Conclusão: A angio-RM sem contraste proporciona imagens de alta qualidade dos segmentos extrarrenais das artérias renais. Este método pode ser alternativamente utilizado para avaliação renal, com acurácia comparável à da angio-TC.

3.
Radiol. bras ; 50(4): 216-223, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-896090

ABSTRACT

Abstract Objective: The purpose of this study was to compare two short-tau inversion recovery (STIR) sequences, Cartesian and radial (BLADE) acquisitions, for breast magnetic resonance imaging (MRI) examinations. Materials and Methods: Ninety-six women underwent 1.5 T breast MRI exam (48 Cartesian and 48 BLADE). Qualitative analysis including image artifacts, image quality, fat-suppression, chest-wall depiction, lesion detection, lymph node depiction and overall impression were evaluated by three blinded readers. Signal to noise ratios (SNRs) were calculated. Cronbach's alpha test was used to assess inter-observer agreement. Subanalyses of image quality, chest-wall depiction and overall impression in 15 patients with implants and image quality in 31 patients with clips were correlated using Pearson test. Wilcoxon rank sum test and t-test were performed. Results: Motion artifacts were present in 100% and in 0% of the Cartesian and the BLADE exams, respectively. Chemical-shift artifacts were present in 8% of the Cartesian exams. Flow artifacts were more frequent on BLADE. BLADE sequence was statistically superior to Cartesian for all qualitative features (p < 0.05) except for fat-suppression (p = 0.054). In the subanalysis, BLADE was superior for implants and clips (p < 0.05). SNR was statistically greater for BLADE (48.35 vs. 16.17). Cronbach ranged from 0.502 to 0.813. Conclusion: BLADE appears to be superior to Cartesian acquisition of STIR imaging as measured by improved image quality, fewer artifacts, and improved chest wall and lymph node depiction.


Resumo Objetivo: Comparar duas sequências de aquisição, cartesiana e radial (BLADE) ponderadas em short-tau inversion recovery (STIR), em exames de ressonância magnética de mama. Materiais e Métodos: Noventa e seis pacientes foram submetidas a exame de ressonância magnética de mama em 1,5 T (48 aquisições STIR cartesianas e 48 aquisições STIR BLADE). A análise qualitativa incluindo artefatos, qualidade de imagem, supressão de gordura, avaliação da parede torácica, detecção de lesões, linfonodos e impressão geral foi avaliada independentemente por três leitores. Os signal to noise ratios (SNRs) foram calculados. Foi utilizado o teste alfa de Cronbach para avaliar a concordância interobservador. Subanálises da qualidade de imagem, avaliação da parede torácica e impressão geral em 15 pacientes com implantes e qualidade de imagem em 31 pacientes com clipes cirúrgicos foram correlacionadas aplicando o teste de Pearson. Os testes de Wilcoxon rank sum test e Student t foram utilizados para comparação qualitativa e quantitativa entre as duas sequências. Resultados: Os artefatos de movimento estavam presentes em 100% e 0% dos exames de aquisição cartesiana e de BLADE, respectivamente. Os artefatos de desvio químico estavam presentes em 8% dos exames cartesianos. Artefatos de fluxo foram mais frequentes nas sequências BLADE. A sequência BLADE foi estatisticamente superior para todos os atributos qualitativos (p < 0,05), exceto na supressão de gordura (p = 0,054). O BLADE foi superior na avaliação dos implantes e clipes cirúrgicos (p < 0,05). O SNR foi estatisticamente superior na sequência BLADE (48,35 versus 16,17). Cronbach variou entre 0,502 e 0,813. Conclusão: A sequência BLADE foi superior à sequência de aquisição cartesiana de imagens na ponderação STIR, comprovada por uma melhor qualidade de imagem, menos artefatos e melhor avaliação da parede torácica e de linfonodos.

4.
Radiol. bras ; 50(2): 115-125, Mar.-Apr. 2017. graf
Article in English | LILACS | ID: biblio-842459

ABSTRACT

Abstract In the second part of this review, we will describe the ancillary imaging features of hepatocellular carcinoma (HCC) that can be seen on standard magnetic resonance imaging (MRI) protocol, and on novel and emerging protocols such as diffusion weighted imaging and utilization of hepatocyte-specific/hepatobiliary contrast agent. We will also describe the morphologic sub-types of HCC, and give a simplified non-invasive diagnostic algorithm for HCC, followed by a brief description of the liver imaging reporting and data system (LI-RADS), and MRI assessment of tumor response following locoregional therapy.


Resumo Na segunda parte desta revisão descreveremos os achados de imagem auxiliares para o diagnóstico de carcinoma hepatocelular (CHC) e que podem ser observados num protocolo de ressonância magnética (RM) padrão e em protocolos emergentes que incluem imagens de difusão e aplicação de contrastes hepatoespecíficos/hepatobiliares. Descreveremos também os subtipos morfológicos de CHC e um algoritmo diagnóstico não invasivo simplificado para o CHC, seguido de uma breve descrição do liver imaging reporting and data system (LI-RADS) e avaliação por RM após terapêutica locorregional.

5.
Radiol. bras ; 50(1): 19-25, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-842438

ABSTRACT

Abstract Objective: To describe a modified approach to the evaluation of adrenal nodules using a standard abdominal magnetic resonance imaging protocol. Materials and Methods: Our sample comprised 149 subjects (collectively presenting with 132 adenomas and 40 nonadenomas). The adrenal signal intensity index was calculated. Lesions were grouped by pattern of enhancement (PE), according to the phase during which the wash-in peaked: arterial phase (type 1 PE); portal venous phase (type 2 PE); and interstitial phase (type 3 PE). The relative and absolute wash-out values were calculated. To test for mean differences between adenomas and nonadenomas, Student's t-tests were used. Receiver operating characteristic curve analysis was also performed. Results: The mean adrenal signal intensity index was significantly higher for the adenomas than for the nonadenomas (p < 0.0001). Chemical shift imaging showed a sensitivity and specificity of 94.4% and 100%, respectively, for differentiating adenomas from nonadenomas. Of the adenomas, 47.6%, 48.5%, and 3.9%, respectively, exhibited type 1, 2, and 3 PEs. For the mean wash-in proportions, significant differences were found among the enhancement patterns. The wash-out calculations revealed a trend toward better lesion differentiation for lesions exhibiting a type 1 PE, showing a sensitivity and specificity of 71.4% and 80.0%, respectively, when the absolute values were referenced, as well as for lesions exhibiting a type 2 PE, showing a sensitivity and specificity of 68.0% and 100%, respectively, when the relative values were referenced. The calculated probability of a lipid-poor lesion that exhibited a type 3 PE being a nonadenoma was > 99%. Conclusion: Subgrouping dynamic enhancement patterns yields high diagnostic accuracy in differentiating adenomas from nonadenomas.


Resumo Objetivo: Descrever uma abordagem modificada para a avaliação de nódulos adrenais utilizando um protocolo padrão de ressonância magnética abdominal. Materiais e Métodos: A nossa amostra foi composta de 149 indivíduos (132 adenomas e 40 não adenomas). O índice de intensidade do sinal adrenal foi calculado. As lesões foram agrupadas em três grupos de acordo com o tempo de wash-in até atingir o pico de realce (arterial, tipo 1 PE; portal-venoso, tipo 2 PE; ou intersticial, tipo 3 PE). O wash-out relativo e o absoluto foram calculados. O teste t de Student foi utilizado para examinar diferenças entre adenomas e não adenomas. A análise da curva ROC foi realizada. Resultados: O índice de intensidade médio do sinal adrenal dos adenomas adrenais foi significativamente maior (p < 0,0001). A imagem de fora-de-fase teve sensibilidade de 94,4% e especificidade de 100% para diferenciar adenomas de não adenomas. Do total de adenomas, 47,6% exibiram tipo 1 PE, 48,5% tipo 2 PE e 3,9% tipo 3 PE. Para todos os padrões de realce foram encontradas diferenças significativas para as porcentagens médias de wash-out. Houve tendência para uma melhor diferenciação da lesão utilizando o cálculo absoluto de wash-out para lesões apresentando tipo 1 PE e wash-out relativo para lesões apresentando tipo 2 PE, com sensibilidade e especificidade de 71,4% e 80% e 68% e 100%, respectivamente. A probabilidade calculada de uma lesão pobre em lipídios exibir um padrão tipo 3 PE de ser um não adenoma foi superior a 99%. Conclusão: O agrupamento de padrões dinâmicos de realce proporciona elevada precisão diagnóstica na diferenciação de adenomas de não adenomas adrenais.

6.
Radiol. bras ; 50(1): 38-47, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-842447

ABSTRACT

Abstract Magnetic resonance imaging (MRI) is the modern gold standard for the noninvasive evaluation of the cirrhotic liver. The combination of arterial phase hyperenhancement and delayed wash-out allows a definitive diagnosis of hepatocellular carcinoma (HCC) in patients with liver cirrhosis or chronic liver disease, without the requirement for confirmatory biopsy. That pattern is highly specific and has been endorsed in Western and Asian diagnostic guidelines. However, the sensitivity of the combination is relatively low for small HCCs. In this two-part review paper, we will address MRI of the cirrhotic liver. In this first part, we provide a brief background on liver cirrhosis and HCC, followed by descriptions of imaging surveillance of liver cirrhosis and the diagnostic performance of the different imaging modalities used in clinical settings. We then describe some of the requirements for the basic MRI technique, as well as the standard MRI protocol, and provide a detailed description of the appearance of various types of hepatocellular nodules encountered in the setting of the carcinogenic pathway in the cirrhotic liver, ranging from regenerative nodules to HCC.


Resumo A ressonância magnética (RM) é o método padrão para a avaliação não invasiva do fígado cirrótico. A combinação de hiper-realce arterial e wash-out tardio permite um diagnóstico definitivo de carcinoma hepatocelular (CHC) em pacientes com cirrose hepática ou doença hepática crônica, sem a necessidade de biópsia confirmatória. Este padrão é altamente específico e tem sido utilizado por guidelines de diagnóstico ocidentais e asiáticas. No entanto, a sensibilidade desta combinação é relativamente baixa para CHCs pequenos. Neste artigo de revisão de duas partes, irá ser efetuada uma revisão do papel da RM na avaliação do fígado cirrótico. Na primeira parte, faremos uma breve revisão sobre cirrose hepática e CHC, seguido da vigilância da cirrose hepática por imagem e desempenho diagnóstico das diferentes modalidades de imagem utilizadas na prática clínica. Depois, descreveremos alguns dos requisitos técnicos básicos para RM, protocolos de RM e uma descrição detalhada do aparecimento dos diferentes nódulos hepatocelulares encontrados no contexto da via carcinogênica do fígado cirrótico, desde nódulos regenerativos a CHC.

8.
Radiol. bras ; 49(5): 288-294, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-829398

ABSTRACT

Abstract Objective: To determine common imaging findings of hepatic epithelioid hemangioendothelioma on magnetic resonance images. Materials and Methods: A search was made of three institutional databases between January 2000 and August 2012. Seven patients (mean age, 47 years; range, 21-66 years; 6 women) with pathology-confirmed diagnosis of hepatic epithelioid hemangioendothelioma who had undergone magnetic resonance imaging were identified. None of the patients had received any treatment for hepatic epithelioid hemangioendothelioma at the time of the initial magnetic resonance imaging examination. Results: Hepatic epithelioid hemangioendothelioma tumors appeared as focal masses in 7/7 patients, greater than 5 in number, with a coalescing lesion in 1/5, and peripheral localization in 6/7. Capsular retraction was present in 4/7, and was associated with peripherally located lesions. Early ring enhancement was appreciated in the majority of lesions in 7/7 patients. Centripetal progressive enhancement was shown in 5/7 patients on venous phase that exhibited a distinctive thick inner border of low signal on venous phase images, and a central core of delayed enhancement. Small lesions did not show this. Conclusion: The combination of multifocal round-configuration lesions that are predominantly peripheral and exhibit early peripheral ring enhancement and late appearance of an inner thick border of low signal and central core of high signal may represent an important feature for hepatic epithelioid hemangioendothelioma.


Resumo Objetivo: Determinar os achados comuns de hemangioendotelioma epitelioide hepático em imagens de ressonância magnética. Materiais e Métodos: Uma pesquisa foi feita em três bases de dados institucionais entre janeiro de 2000 e agosto de 2012. Sete pacientes (média de idade, 47 anos; variação, 21-66 anos; 6 mulheres) com diagnóstico confirmado por exame patológico de hemangioendotelioma epitelioide hepático submetidos a ressonância magnética foram identificados. Nenhum dos pacientes havia recebido tratamento para hemangioendotelioma epitelioide hepático antes do exame inicial por ressonância magnética. Resultados: Tumores de hemangioendothelioma epitelioide hepático apareceram como massas focais, maiores que 5 em número, em 7/7 pacientes, com uma lesão coalescente em 1/5 e localização periférica em 6/7 pacientes. Retração capsular esteve presente em 4/7 pacientes e foi associada com lesões perifericamente localizadas. Realce precoce em anel foi visto na maioria das lesões, em 7/7 pacientes. Realce progressivo centrípeto foi demonstrado em 5/7 pacientes na fase venosa, que exibia uma borda interna espessa distinta de baixo sinal nas imagens de fase venosa e um núcleo central de realce tardio. As lesões pequenas não mostraram isso. Conclusão: A combinação de lesões de configuração arredondada multifocais que são predominantemente periféricas e exibem realce precoce em anel periférico e aparecimento tardio de uma borda espessa interna de baixo sinal e um núcleo central de alto sinal pode representar uma característica importante para hemangioendotelioma epitelioide hepático.

SELECTION OF CITATIONS
SEARCH DETAIL