Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiology ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-679370

ABSTRACT

Objective To investigate the CT findings of Madelung's disease in the head and neck region,and to evaluate the value of CT in demonstrating the Madelung's disease in the head and neck region.Methods CT findings of Madelung's disease in the head and neck region in 7 cases were analyzed retrospectively.All were males,with the age from 36 to 60 years,mean 51 years.All patients were underwent CT native scan,and enhanced CT scan was performed on 3 of them.Results CT images in the neck of all patients showed accumulation of nonencapsulated fat within the subcutaneous tissue and(or) deep to the platysma,and(or)within the spaces between the muscles.The fat deposits were ill-defined and symmetrical.In most cases the fat deposits involved the anterior part of the neck(infrahyoid and suprahyoid),submandibular region,the subcutaneous tissue of the nape and deep to the stenomastoid muscles.Conclusions Madelung's disease in the head and neck region have characteristic CT findings,and CT has great value in qualitative and quantitative diagnosis in Madelung's disease.

2.
Chinese Journal of Radiology ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-679366

ABSTRACT

Objective To evaluate the imaging methods,characteristics,diagnostic value of multi- slice CT urography(MSCTU)in congenital abnormities of urinary system.Methods To collect 33 urinary congenital abnormities cases in three years and to analyses these MSCTU images.All examinations were performed with a multi-slice spiral CT scanner.The patients were intravenously injected with 90 ml of Iohexol 300 with a power injector at the rate of 3 ml/s.Nephrographic-phase images were obtained at 75 s after initiation of the injection of contrast material,the appropriate delay time is according to Kidney's enhancement extent and nephrohydrosis degree.Excretory-phase images were obtained through the abdomen and pelvis from 10 min.to 23 h after initiation of the injection of contrast material without abdominal compression.Excretory-phase images were transferred to the workstation and performed maximun intensity projection(MIP),multiplanar reconstruction(MPR),volume rendering(VR),and virtual cystoscopy (VC).Results The urinary congenital abnormities diagnosed by MSCTU in 33 cases,including 1 ectopic kidney,1 horseshoe kidney,1 renal malrotaion,2 supernumerary kidneys,2 ureteral valves,2 retrocaval ureters,4 congenital megaureters,6 ureteropelvic junction stenosis,9 pelviureteric duplication malformations and 5 bladder diverticula.The displaying rate of ureter was 91%(61/66).The scanning time of excretory-phase was less than 20 seconds in All cases.The average CT value of contrast media in displayed ureter lumens was 520 HU.The postprocessing images had clear,dimensional feature and It was satisfy the diagnosis.Conclusion MSCTU has clear,dimensional feature and has strong ability of displaying total anatomy shape and tiny pathology change of congenital abnormities in the urinary system.It is a very useful method for detecting the congenital abnormities in the urinary system.

SELECTION OF CITATIONS
SEARCH DETAIL