Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Int. j. cardiovasc. sci. (Impr.) ; 31(3): 218-225, jul.-ago. 2018. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-908839

ABSTRACT

Fundamento: As doenças cardiovasculares são a principal causa de morte no Brasil. Marcadores bioquímicos possuem importância diagnóstica e prognóstica nas síndromes coronarianas agudas (SCAs), sendo a troponina o biomarcador preferido. Estudos já demonstram relação positiva entre elevação da troponina ultrassensível (TnUs) e prognóstico. Entretanto, poucos relacionam seus níveis com a complexidade das lesões coronárias. Objetivos: Comparar níveis de TnUs com a complexidade das lesões coronarianas pelo escore SYNTAX e relacionar os escores TIMI e GRACE com os níveis desse biomarcador em pacientes com SCA. Métodos: Estudo retrospectivo, transversal com 174 indivíduos com SCA. A correlação entre as variáveis foi avaliada pelo teste de correlação linear não paramétrico de Spearman e a análise estatística realizada pelo programa SPSS, com nível de significância de 5%. Resultados: A média de idade foi 63 anos, predominando o sexo feminino (52,9%). A maioria dos pacientes era hipertensa, não diabética e não tabagista. Dos pacientes avaliados, 19,0% apresentaram IAM com SST, 43,1% IAM sem SST e 36,8% angina instável. A maioria encontrava-se em Killip 1 (82,8%). A mediana de TnUs foi de 67pg/ml. As medianas dos escores de risco foram de 3, 121 e 3 pontos nas escalas TIMI, GRACE e SYNTAX, respectivamente. Houve correlação da taxa de TnUs com os escores SYNTAX (p < 0,001, r = 0,440), TIMI (p < 0,001, r = 0,267) e GRACE (p = 0,001, r = 0,261). Conclusão: Encontrada correlação linear positiva entre os níveis de TnUs e complexidade das lesões coronarianas, assim como entre esse biomarcador e os escores clínicos TIMI e GRACE


Background: Cardiovascular diseases are the leading cause of death in Brazil. Biochemical markers have diagnostic and prognostic importance in acute coronary syndromes (ACSs), with troponin as the preferred biomarker. Studies have already demonstrated a positive relationship between increased levels of high-sensitivity troponin (hsTn) and prognosis. However, few studies have correlated hsTn levels with the complexity of coronary lesions. Objectives: To compare hsTn levels with the complexity of coronary lesions according to the SYNTAX score, and to correlate the levels of this biomarker with the TIMI and GRACE scores in patients with ACS. Methods: Retrospective, cross-sectional study with 174 patients with ACS. The correlation between variables was assessed by the nonparametric Spearman's rank correlation, and statistical analysis was performed by the SPSS program, with a significance level of 5%. Results: Mean age was 63 years, and most patients were women (52.9%), hypertensive, non-diabetic and non-smokers. Nineteen percent of the patients had STEMI, 43.1% NSTEMI, and 36.8% unstable angina. Most were in Killip 1 (82.8%). Median hsTn was 67 pg/mL. Median risk scores were 3, 121 and 3 in the TIMI, GRACE and SYNTAX scores, respectively. There was a correlation of hsTn with SYNTAX (p <0.001, r = 0.440), TIMI (p < 0.001, r = 0.267) and GRACE (p = 0.001, r = 0.261) scores. Conclusion: A positive linear correlation was found of hsTn levels with the complexity of coronary lesions, and with the TIMI and GRACE


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Troponin , Coronary Vessels/pathology , Acute Coronary Syndrome/therapy , Prognosis , Biomarkers , Cardiovascular Diseases/mortality , Data Interpretation, Statistical , Retrospective Studies , Computed Tomography Angiography/methods , Hospitalization/economics , Angina, Unstable/diagnosis , Angina, Unstable/therapy , Myocardial Infarction/diagnosis , Myocardial Infarction/mortality
2.
Rev. bras. med. esporte ; 10(6): 468-474, nov.-dez. 2004. ilus, tab, graf
Article in Portuguese, English | LILACS | ID: lil-398535

ABSTRACT

A presença de lesões no tornozelo torna necessária a mensuração do edema como fator diagnóstico e evolutivo. O presente trabalho teve como objetivo analisar a confiabilidade do método Figura Oito e da volumetria para a mensuração do volume do tornozelo, intrateste e interteste. Vinte voluntários, sexo masculino, assintomáticos, idade entre 15 e 30 anos (X= 21,8), foram avaliados aleatoriamente por três examinadores; cada um realizou três mensurações utilizando o método Figura Oito e três, a volumetria. A ordem dos examinadores e da técnica de mensuração foi aleatória. Observou-se excelente confiabilidade nas duas técnicas (ICC = 0,99). O coeficiente de correlação momento-produto de Pearson demonstrou similaridade entre os examinadores; o primeiro apresentou r = 0,91, o segundo, r = 0,95 e o terceiro, r = 0,96. Concluiu-se que os dois métodos são confiáveis, apesar de a maioria dos autores recomendar o método Figura Oito pela sua praticidade, rapidez e baixo custo.


Subject(s)
Humans , Male , Adolescent , Adult , Ankle Joint , Joint Diseases/diagnosis , Edema/diagnosis , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL