Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add filters








Year range
2.
Araraquara; s.n; 2009. 150 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-590733

ABSTRACT

O objetivo deste estudo foi avaliar o efeito da adição de óxido de zircônio, em diferentes concentrações e temperaturas de sinterização, na tenacidade à fratura (KIC) e na dureza Vickers (HV) da porcelana feldspática Duceragold. Foram confeccionados discos cerâmicos (9,0 x 3,0mm; n=10) para os grupos: (G1) Duceragold sem adição de ZrO2, (G2) Duceragold adicionada de 1% de ZrO2, (G3) 2% de ZrO2, (G4) 3% de ZrO2, (G5) 4% de ZrO2, (G6) 5% de ZrO2, (G7) 6% de ZrO2 e (G8) 7% de ZrO2, sinterizados a: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 ºC e (e) 1000 ºC, totalizando 400 corpos-de-prova. Após a sinterização, em forno Alumini Press, procedeu-se sua inclusão e polimento até lixa 1500 em politriz. A HV foi mensurada em durômetro Buelher, com carga de 9,8 N, por 20 segundos; as imagens obtidas foram capturadas por meio de câmera JVC e os cálculos de KIC, executados com auxílio do software Laica. Para observação da superfície das amostras, foram realizadas fotomicrografias por MEV. Os resultados de KIC e HV foram submetidos a ANOVA e teste de Tukey (p!0,05). Observou-se que, independentemente da temperatura de sinterização, o aumento da concentração de óxido de zircônio, aumenta o KIC, todavia, a partir de 6%, a HV diminui; independentemente da concentração, o aumento da temperatura de sinterização proporciona aumento dos valores de HV, contudo, temperaturas de 950ºC e 1000ºC diminuem o KIC; com o aumento da concentração de óxido de zircônio e da temperatura de sinterização, aumentam o número de poros tanto na fase vítrea da porcelana, quanto na fase dispersa de zircônia. Considerando as propriedades estudadas e a caracterização da superfície, pode-se observar que as amostras com adição de até 4% de óxido de zircônio à porcelana feldspática Duceragold, sinterizadas em temperaturas de até 900ºC apresentam-se como as mais promissoras.


The objective of this study was to evaluate the effect of adding zirconium oxide at different concentrations and temperatures of sintering, on the fracture toughness (KIC) and Vickers hardness (HV) of feldspathic porcelain Duceragold. Ceramic discs were prepared (9.0 x 3.0 mm, n = 10) for the groups: (G1) Duceragold without the addition of ZrO2, (G2) Duceragold added 1% of ZrO2, (G3) 2% of ZrO2, (G4) 3% of ZrO2, (G5) 4% of ZrO2, (G6) 5% of ZrO2, (G7) 6% of ZrO2 and (G8) 7% of ZrO2, sintered at: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 °C and (e) 1000 ºC, totaling 400 specimens of the samples. After sintering at Alumini Press furnace, inclusion and polishing by sandpaper polishing (# 1500) were proceeded. The HV was measured in a Buelher durometer, with a load of 9.8 N for 20 seconds, the images were captured using a JVC camera and calculation of KIC, performed with the aid of software Laica. To observe the surface of the samples were performed by SEM photomicrographs. The results of KIC and HV were submitted to ANOVA and Tukey's test (p ! 0.05). It was observed that regardless of sintering temperature, the concentration of zirconium oxide, increases the KIC, however, from 6%, HV decreases; regardless of the concentration, the increase of sintering temperature gives increased HV values, however, temperatures of 950 °C and 1000 °C decrease the KIC; with increasing concentration of zirconium oxide and sintering temperature, increase the number of pores in the vitreous and dispersed phase of zirconia. Considering the studied properties and characterization of the surface can be observed that the samples with the addition of up to 4% zirconium oxide in Duceragold feldspathic porcelain, sintered at temperatures up to 900 º C are presented as the most promising.


Subject(s)
Dental Materials , Dental Porcelain , Dental Prosthesis
3.
Ciênc. odontol. bras ; 12(1): 63-69, 2009. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-524156

ABSTRACT

Neste trabalho foram analisadas as possíveis alterações promovidas pela incorporação de agentes desinfetantes na resistência à compressão, estabilidade dimensional linear e resistência à tração diametral de modelos em gesso. As amostras foram confeccionadas em gesso pedra tipo III e divididas nos seguintes grupos: Grupo 1- controle (espatulado de acordo com as recomendações do fabricante); Grupo 2- adição de 0,5 % de hipoclorito de cálcio; Grupo 3- adição de 1,0 % de hipoclorito de cálcio; Grupo 4- adição de 1,5 % de hipoclorito de cálcio. Baseado nos resultados obtidos pode se observar que a incorporação de hipoclorito de cálcio influenciou negativamente nos valores de resistência a tração diametral do gesso avaliado, aspecto também observado na resistência a compressão com a incorporação de hipoclorito de cálcio 1,5%. A análise da estabilidade dimensional demonstrou que o agente desinfetante promoveu uma diminuição na expansão de presa apresentada pelo gesso. Com isso, concluímos que a incorporação de hipoclorito de cálcio promove uma tendência à diminuição da expansão apresentada durante a presa do gesso, porém esta incorporação acarreta uma diminuição na resistência dos modelos de gesso.


Subject(s)
Calcium Sulfate , Disinfection , Tensile Strength
4.
Arq. odontol ; 43(4): 137-143, out.-dez. 2007. tab
Article in Portuguese | LILACS, BBO | ID: lil-533413

ABSTRACT

Este estudo objetivou avaliar a capacidade de reprodução de detalhes presentes no molde por materiais de modelagem à base de gipsita Gesso pedra tipo IV, Durone, (Dentsply); Gesso pedra tipo IV, Fuji Rock EP,(GC); Gesso pedra tipo IV, Resinado Rock Plus, (Polidental); Gesso pedra tipo V, Durone, (Dentsply) epolímeros: resinas epóxicas Epoxiglass 1504, (Epoxiglass), resina epóxica Epoxiglass 1504 modificada com diatomita pura e silanizada. A resina e seu endurecedor foram carregados com diatomita numa relação de30%. A diatomita foi tratada com Silano Silquest A 187, (Crompton S/A). A resina modificada foi manipuladaem uma relação de 35%. Empregando-se silicona de adição Presidente (Kit de silicona leve e pesada, Coltène) realizaram-se três moldagens de uma matriz metálica com quatro hastes contendo sulcos dimensionados. Os corpos de prova foram analisados em microscópio óptico com aumento de 40 vezes (Measurescope Nikon, procedência Nippon Kogaru K. K.). Os resultados expressos por gessos e resinas foram analisados com o teste Variância e Tukey (p<0,05). Verificou-se que não há diferenças estatisticamente significantes entre os gessos e resinas analisadas. Concluiu-se que o carregamento da resina epóxica com diatomita ou com diatomita silanizada não reduz a sua capacidade em reproduzir detalhes presentes no molde. Com a metodologia empregada, não houve diferença entre gessos tipo IV e V e resina epóxica pura ou modificada com diatomita na capacidadede reprodução de detalhes presentes no molde.


Subject(s)
Dental Impression Materials/analysis , Epoxy Resins/analysis , Calcium Sulfate/analysis , Analysis of Variance , Data Interpretation, Statistical
5.
Rev. odontol. UNESP ; 35(4): 247-252, out.-dez. 2006. tab
Article in Portuguese | LILACS, BBO | ID: biblio-858462

ABSTRACT

O cimento de ionômero de vidro foi desenvolvido a partir da união de dois outros materiais, o cimento de silicato e o cimento policarboxilato de zinco. Mesmo com a evolução desses materiais, a propriedade solubilidade/desintegração ainda está pouco clara na literatura. O objetivo deste trabalho foi avaliar comparativamente a solubilidade e desintegração de cimentos de ionômero de vidro modificados por resina e de compômeros, bem como, a necessidade ou não de aplicação de agentes de proteção sobre suas superfícies. Os materiais utilizados foram: M1-Vitremer (3M Co.); M2-Fuji II LC (GCAmerica Inc.); M3-Dyract (Dentsply); e M4-Compoglass (Vivadent). Os agentes de proteção superficial utilizados foram: P1-Fluroshield (Dentsply) e P2-FinishingGloss (3M Co.). Estes materiais foram submetidos a testes de solubilidade e desintegração de acordo com a norma ISO 7489 de 1986. Aos resultados foram aplicadas transformações angulares e submetidos à análise de variância (p < 0,05) a dois critérios fixos e teste de homogeneidade. Os cimentos de ionômero de vidro modificados por resina e os compômeros apresentaram diferentes valores de solubilidade e desintegração. O menor valor foi obtido pelo Dyract, seguido pelo Fuji II LC e Compoglass com valores intermediários e Vitremer com o maior valor. Concluiu-se que os materiais submetidos à proteção superficial apresentaram menores valores de solubilidade e desintegração que os não protegidos; os agentes protetores, Finishing Gloss e Fluroshield mostraram-se eficazes para proteção superficial dos cimentos de ionômero de vidro modificados por resina e compômeros


The glass ionomer cement was developed from two other materials, the silicate cement and the zinc policarboxilate cement. Even though these materials have been enhanced since their creation, the solubility/disintegration properties are still not clear in the specific literature. This study main purpose was to evaluate the solubility and disintegration of resin modified glass ionomer cements as well as the necessity of using coating materials over their surface. M1-Vitremer (3M ESPE); M2-Fuji II LC (GCAmerica Inc.); M3-Dyract (Dentsply); and M4-Compoglass(Vivadent) were used in this study. The coating materials used were P1- Fluroshield (Dentsply) and P2-Finishing Gloss (3M ESPE). These materials underwent solubility and disintegration tests according to ISO 7489 policies from 1986. The results were submitted to angular transformations and variance analysis and homogeneity test suggesting: the resin modified glass ionomer cements and compomers showed different solubility and disintegration rates, Dyract < Fuji II LC = Compoglass < Vitremer; the resin modified glass ionomer cements and compomers submitted to the surface protection showed lower solubility and disintegration rates contrasted to the non-protected specimens; Finishing Gloss and Fluroshield demonstrated effective surface protection for resin modified glass ionomer cements and compomers


Subject(s)
Analysis of Variance , Glass Ionomer Cements , Resin Cements , Compomers , Solubility
6.
Arq. odontol ; 42(1): 33-39, 2006. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-457321

ABSTRACT

O objetivo deste estudo foi avaliar o pH de agentes clareadores a base de carbamida a 10 por cento e 16 por cento disponíveis comercialmente Whiteness Standard (FGM), Review (SSWhiate) e Whteness Perfect (FGM) e manipulados em farmácia de manipulação. A análise do pH foi conduzida utilizando um pHmetro Micronal B474, calibrado em 4,00 e 7,00 com solução tampão ácido cítrico/hidrogênio fosfato de sódio, empregando-se solução KCl 3 mol L. Três gramas de cada amostra foram depositadas em tubo de ensaio recobrindo todo bulbo do eletrodo. O processo foi repetido 8 vezes para cada agente clareador. O eletrodo era lavado entre cada amostra usando água corrente e ácido acético a 4 por cento para remoção completa do agente clareador. O eltrodo foi lavado com água destilada, seco com papel absorvente e a calibração conferida. Aguardava-se 3 minutos para cada leitura, em temperatura ambiente de 24±1ºC. O pH dos produtos clareadores variou de 4,060 (agente manipulado 10 por cento) a 6,212 (Whiteness Standard 10 por cento)...


Subject(s)
Tooth Bleaching/adverse effects , Peroxides/administration & dosage , Data Interpretation, Statistical , Hydrogen-Ion Concentration
7.
Odonto (Säo Bernardo do Campo) ; 13(26): 33-40, jul.-dez. 2005. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-518528

ABSTRACT

No presente trabalho, avaliou-se, através de ensaios mecânicos de cisalhamento, a resistência de união à dentina de peças metálicas fundidas em liga de prata cimentadas com quatro tipos de cimentos odontológicos. Foram selecionados quarenta dentes molares humanos íntegros e fixados com resina acrílica em tubos plásticos de PVC. A seguir, cada coroa dental foi então seccionada na altura do terço oclusal deixando a dentina exposta. A liga de prata foi preparada em pastilhas com 3mm de espessura. Antes da cimentação, cada pastilha recebeu um jateamento de óxido de alumínio de 0,05µm de granulação, por 15 segundos e com pressão de 70/80 libras. O processo de cimentação, para cada tipo de cimento, foi realizado de acordo com as instruções dos fabricantes. Os ensaios mecânicos de cisalhamento foram realizados na máquina MTSû810 Material Test System utilizando uma carga de 100 Kgf e velocidade de pressão de 0,05 mm/min. Para verificar a diferença significativa entre os tratamentos, realizou-se a análise de variância e teste de Tuckey ao nível de significância de 5 %. Os resultados obtidos nos levaram a concluir que: 1) G2 (cimento resinoso RelyX Cement) apresentou, numericamente, a maior média dos valores de união, seguido em ordem decrescente por G1 (cimento de ionômero de vidro modificado com resina RelyX Luting), G4 (cimento de ionômero de vidro Ketac Cem) e G3 (fosfato de zinco); 2) As médias dos valores de união, de todos os grupos, foram diferentes estatisticamente entre si.


This work evaluated, through mechanical shearing assays, the strength of bonding to dentine of silver alloy metallic pieces, bonded with four types of dental cements. Fortywhole human molar teeth were selected and fixed, with acrylic resin, to û inch plastic PVC tubing segments. Following this, each dental crown was sectioned at the oclusal third, M-D direction, exposing the dentine. The silver alloy was prepared as 3mm-thick discs. Before cementation, each disc was blasted withaluminum oxyde (0.05mm grain), during 15 seconds, at a 70/80 pounds pressure. The cementation process, for each cement,followed the manufactureræs instructions. The mechanical shearing assays were performed with a MTS-810 Material TestSystem machine, at 100 Kgf load and 0.05 mm/min pressure speed. The results were statistically analysed with ANOVAand Tuckeyæs test at 5% significance level. The results allowed the following conclusions: 1) G2 (resin cement RelyX) offered,numerically, the greatest average bonding value, followed, in decrescent order, by G1 (glass ionomer modifyed with RelyXLuting resin), G4 (standard glass ionomer cement Ketac Cem) and G3 (zinc phosphate); 2) The average bonding values,in all groups, were statistically different.


Subject(s)
Dental Alloys , Dental Cements , Dentin , Shear Strength
8.
Rev. odontol. UNESP ; 34(4): 179-183, out.-dez. 2005. ilus
Article in Portuguese | LILACS, BBO | ID: lil-502377

ABSTRACT

Os autores apresentam, por meio de um caso clínico, uma técnica alternativa de moldagem com casquete individual utilizando como material afastador e moldador siliconapolimerizada por condensação pesada e leve para ser utilizado em pacientes que apresentam alergia ao monômero de metacrilato de metilo, suprimindo a fase de reembasamento do casquete com resina acrílica.


The authors present, an alternative impression technique with individual tray using heavy and light condensation silicone as reliner and casting material. This technique may be used in patients with allergic reaction caused by methyl methacrylate monomer, suppressing the relining phase of the individual tray with acrylic resin.


Subject(s)
Crowns , Dental Impression Materials , Denture, Partial, Fixed , Dental Impression Technique
9.
Odonto (Säo Bernardo do Campo) ; 13(25): 52--58, jan.-jun. 2005. graf
Article in Portuguese | LILACS, BBO | ID: lil-428151

ABSTRACT

Este estudo teve como objetivo avaliar o grau de microinfiltração marginal de restaurações de resina composta. Os materiais utilizados foram resina composta Charisma e os adesivos dentinários, Scothbond Multiuso Plus, Single Bond e Prompt L-Pop. Vinte e um dentes pré-molares humanos, recém extraídos foram selecionados e divididos em três grupos, nestes foram preparadas na face vestibular e lingual cavidades padronizadas classe V, tendo a margem gengival localização em dentina e envolvidos. Os dentes restaurados foram isolados com resina epóxica (araldite/Ciba), preservando as restaurações e 2,0mm ao seu redor. Em seguida foram submetidos à ciclagem térmica e imersos em Rodamina B a 0,2%. A extensão da penetração por método não paramétrico (teste de significância para igualdade de duas proporções), com p<0,05. Os resultados de microinfiltração marginal encontrados, para cada um dos três sistemas adesivos utilizados, não mostarram diferença estatisticamente significante


Subject(s)
Dental Leakage/etiology , Composite Resins/adverse effects , Dentin-Bonding Agents/adverse effects , Dental Materials/adverse effects
10.
JBC j. bras. clin. odontol. integr ; 9(48): 18-22, jan.-mar. 2005. ilus
Article in Portuguese | LILACS, BBO | ID: lil-455229

ABSTRACT

Os autores demonstram a utilização da técnica de microabrasão de esmalte manchado por fluorose, grau 3, localizada nos dentes 11 e 21 de uma paciente de 15 anos, usando ácido fosfórico a 37% associado à pedra-pomes. A técnica demonstrou-se pouco invasiva, simples, rápida, eficaz e segura, alcançando-se excelente resultado estético


Subject(s)
Humans , Female , Adolescent , Fluorosis, Dental/diagnosis , Enamel Microabrasion/methods , Tooth Bleaching , Dental Enamel , Esthetics, Dental , Phosphoric Acids
11.
Rev. odontol. UNESP ; 33(2): 81-85, abr.-jun. 2004. tab
Article in Portuguese | LILACS, BBO | ID: lil-510857

ABSTRACT

O objetivo deste trabalho foi avaliar a resistência de união de peças metálicas de NiCr tratadas superficialmente (T1 = polido; T2 = polido e silanizado; T3 = polido e jateado com partículas de óxido de alumínio de 10-20 μm; e T4 = polido e jateado com partículas de óxido de alumínio de 50 μm) e cimentadas com um cimento resinoso à dentina bovina. Foram utilizados dez corpos-deprovapor grupo. Para a realização do ensaio mecânico de tração, foi utilizada uma máquina de ensaios MTS 810, com célula de carga de 100 Kgf e velocidade de tração de 1,0 mm por minuto. Apartir dos dados obtidos, foram realizados análise de variância e teste de Tukey, por meio dos quais foi possível concluir que: o jateamento com partículas de óxido de alumínio de 50 μm não resultou em maior força de união; o jateamento com ambas as partículas de óxido de alumínio (10 μm-20 μm e 50 μm) resultou em maior força de união quando comparados o grupo que recebeu polimento e o grupo que recebeu polimento e silanização; a silanização da superfície metálica polida resultou em diminuição significativa da resistência de união.


Subject(s)
Dentin-Bonding Agents , Resin Cements , Dental Alloys
SELECTION OF CITATIONS
SEARCH DETAIL