Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Rev. argent. cardiol ; 91(4): 257-262, nov. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535503

ABSTRACT

RESUMEN La difusión del reemplazo valvular aórtico percutáneo (TAVI) en la estenosis aórtica (EAo) generó la creación de un Heart Team (HT), para elegir el mejor tratamiento. Existen pocos reportes sobre su utilidad. Objetivos: analizar los resultados del tratamiento de los pacientes con EAo evaluados por un HT durante 10 años Material y métodos: Inclusión consecutiva de todos los pacientes con EAo candidatos a TAVI entre enero del 2012 y julio del 2021 para seleccionar el mejor tratamiento, incluyendo además Cirugía de reemplazo valvular aórtico (CRVA) y Tratamiento médico conservador (TMC). Resultados: De 841 pacientes, se asignaron a TAVI 455 (53%), CRVA 213 (24%) y TMC 183 (23%). El porcentaje asignado a TAVI aumentó con el tiempo de 48 a 62% (p < 0,05). Los pacientes que fueron a TAVI, con respecto a los enviados a CRVA, eran mayores (86 ± 7 vs 83 ± 7 años), con mayor EUROSCORE II (6,2, IC95% 5,7-6,6 vs 5,6, IC95% 4,4-6,5) y más frágiles (1,62 ± 1 vs 0,91 ± 1), en todos los casos p <0,01. La sobrevida actuarial (IC 95%) a 1 y a 2 años fue, para TAVI 88% (84-91%) y 82% (77-86%), para CRVA 83% (76-88%) y 78% (70-84%) y para TMC 70% (60-87%) y 59% (48-68%) respectivamente (p <0,001). Conclusiones: Durante los primeros 10 años de establecido un Heart Team para la toma de decisiones en EAo, se asignaron a TAVI aproximadamente la mitad y el resto se asignó por mitades a cirugía u observación. La sobrevida de los pacientes intervenidos fue similar a 2 años y mayor que la de los no intervenidos.


ABSTRACT As transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) became widespread, the need for a Heart Team (HT) arose to choose the best treatment. There are few reports regarding its usefulness. Objectives: To analyze treatment outcomes in patients with AS evaluated by a HT for 10 years. Methods: Consecutive enrollment of all patients with AS who were candidates for TAVI between January 2012 and July 2021 to choose the best treatment, including surgical aortic valve replacement (SAVR) and conservative medical management (CMM). Results: Out of 841 patients, 455 were assigned to TAVI (53%), 213 to SAVR (24%), and 183 to CMM (23%). The percentage assigned to TAVI has increased from 48% to 62% over time (p <0.05). Patients who underwent TAVI versus those who underwent SAVR were older (86 ± 7 vs. 83 ± 7 years), had a higher EUROSCORE II (6.2, 95% CI 5.7-6.6 vs. 5.6; 95% CI 4.4-6.5) and were frailer (1.62 ± 1 vs. 0.91 ± 1), in all cases p <0.01. Actuarial survival (95% CI) at 1 and 2 years was 88% (84-91%) and 82% (77-86%) for TAVI, 83% (76-88%) and 78% (70-84%) for SAVR, and 70% (60-87%) and 59% (48-68%) for CMM, respectively (p <0.001). Conclusions: For the first 10 years after a Heart Team was established for AS decision-making, approximately half of the patients were assigned to TAVI, and the rest were equally assigned in halves to either surgery or observation. Survival for patients who received interventions was similar at 2 years and higher than in those who did not.

3.
Medicina (B.Aires) ; 80(1): 17-22, feb. 2020. ilus, tab
Article in Spanish | LILACS | ID: biblio-1125033

ABSTRACT

La endocarditis infecciosa (EI) es una enfermedad grave y potencialmente letal. La capacidad diagnóstica de los criterios de Duke modificados es alta para válvulas nativas, pero decae en el caso de EI de válvulas protésicas o EI asociadas a dispositivos. El ecocardiograma y los hallazgos microbiológicos son fundamentales para el diagnóstico, pero pueden resultar insuficientes en este grupo de pacientes. Nuestro objetivo fue evaluar la utilidad de la tomografía por emisión de positrones y fusión con tomografía computarizada (PET/TC) en pacientes con sospecha de EI, portadores de válvulas protésicas o dispositivos intracardiacos. Se estudiaron 32 pacientes, a los cuales se les realizó un PET/CT con 18F-Flúor desoxiglucosa (18F-FDG). Se consideraron sugestivos de infección aquellos con captación intensa de tipo focal y/o heterogénea con un punto de corte de Standard Uptake Value (SUV) mayor o igual a 3.7. Los diagnósticos iniciales según los criterios de Duke modificados, se compararon con el diagnóstico final establecido por la Unidad de Endocarditis institucional. El agregado del PET/CT a esos criterios, proporcionó un diagnóstico concluyente en 22 de los 32 casos iniciales, reclasificando a 11 casos en EI definitivas y a otros 5 casos como negativos para ese diagnóstico. La EI continúa siendo un grave problema clínico. En aquellos casos donde los criterios de Duke no son suficientes para establecer el diagnóstico y la sospecha clínica persiste, el PET/CT puede ser una herramienta complementaria útil para aumentar la sensibilidad diagnóstica.


Infective endocarditis (IE) is a serious and potentially lethal condition. The diagnostic capacity of the modified Duke criteria is high for native valves, but it declines in the case of EI of prosthetic valves or EI associated with devices. Echocardiography and microbiological findings are essential for diagnosis but may be insufficient in this group of patients. Our objective was to evaluate the usefulness of positron emission tomography and fusion with computed tomography (PET / CT) in patients with suspected IE, carriers of prosthetic valves or intracardiac devices; 32 patients were studied, who underwent PET / CT with 18F-Fluorine deoxyglucose (18F-FDG). Those with intense focal and/or heterogeneous uptake with a Standard Uptake Value (SUV) cut-off point greater than or equal to 3.7 were considered suggestive of infection. The initial diagnoses according to the modified Duke criteria were compared with the final diagnosis established by the Institutional Endocarditis Unit. The addition of PET / CT to these criteria, provided a conclusive diagnosis in 22 of the 32 initial cases reclassifying 11 cases in definitive EI; another 5 cases were negative for that diagnosis. EI continues to be a serious clinical problem. In those cases where the Duke criteria are not sufficient to establish the diagnosis and clinical suspicion persists, PET / CT can be a useful complementary tool to increase the diagnostic sensitivity.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Pacemaker, Artificial/adverse effects , Heart Valve Prosthesis/adverse effects , Defibrillators, Implantable/adverse effects , Endocarditis/microbiology , Endocarditis/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Pacemaker, Artificial/microbiology , Reference Values , Heart Valve Prosthesis/microbiology , Reproducibility of Results , Sensitivity and Specificity , Prosthesis-Related Infections/diagnostic imaging , Defibrillators, Implantable/microbiology , Statistics, Nonparametric , Fluorodeoxyglucose F18
4.
Medicina (B.Aires) ; 79(4): 257-264, ago. 2019. graf, tab
Article in Spanish | LILACS | ID: biblio-1040518

ABSTRACT

La epidemiología de la endocarditis infecciosa (EI) ha sufrido cambios debido a una serie de factores como el envejecimiento, las comorbilidades y los procedimientos médicos. El objetivo de este estudio fue evaluar las principales modificaciones clínicas, epidemiológicas y etiológicas de la EI en los últimos 25 años en Argentina. Se realizó un análisis comparativo de tres registros prospectivos observacionales en los que se incluyeron de forma consecutiva casos de EI definidas y posibles según los criterios de Duke: dos estudios multicéntricos (EIRA-1 [1992-1994] y EIRA-2 [2001-2002]) y un estudio en un centro de referencia de cardiología de tercer nivel (CRC [2007-2017]). En los 1065 episodios de EI evaluados, no existieron diferencias respecto al sexo, y los pacientes fueron más añosos en cada periodo (p < 0.001). La EI asociada a dispositivos intracardiacos fue más frecuente en la última década: infección asociada a marcapasos (5.4 vs. 23% p < 0.0001) y EI de prótesis valvulares (8.5% vs. 19.2% vs. 47.5% p < 0.0001). Por otra parte, la EI asociada a drogas endovenosas (p < 0.0001) y cardiopatías congénitas (p = 0.001) fue significativamente menos frecuente. La etiología cambió sustancialmente: Streptococcus del grupo viridans disminuyó (30.8% vs. 26.8% vs. 15.9%; p < 0.001) y la EI por Staphylococcus spp. predominó por sobre otros microorganismos, con un aumento estadísticamente significativo del Staphylococcus coagulasa negativa (SCN). El tratamiento quirúrgico fue implementado con más frecuencia en la última década y estuvo acompañado de una tendencia a menor mortalidad en el CRC (23.5%, 24.3% vs. 17.2% p = 0.058).


The epidemiology of infectious endocarditis (IE) has undergone changes due to a series of factors such as aging, comorbidities and medical procedures. The aim of this study was to evaluate the main clinical, epidemiological and etiological changes of the IE in the last 25 years in Argentina. A comparative analysis of three observational prospective registries was performed in which cases of definite and possible IE were consecutively included according to the Duke criteria: two multicentre studies (EIRA-1 [1992-1994] and EIRA-2 [2001-2002]) and one study in a reference cardiology center (CRC [2007-2017]). In the 1065 episodes of EI evaluated, there were no differences regarding sex, and the patients were older in each period (p < 0.001). Intracardiac device-associated IE was more frequent in the last decade: pacemaker (5.4 vs. 23% p < 0.0001) and prosthetic valve IE (8.5% vs. 19.2% vs. 47.5% p < 0.0001). On the other hand, IE associated with intravenous drugs (P < 0.0001) and congenital heart diseases (p = 0.001) was significantly less frequent. The etiology changed substantially: Streptococcus viridans group decreased (30.8% vs. 26.8% vs. 15.9%, p < 0.001) and IE by Staphylococcus spp. predominated over other microorganisms, with a statistically significant increase in IE due to coagulase-negative Staphylococcus. Surgical treatment was more frequently implemented in the last decade and was accompanied by a trend towards lower mortality in the CRC (23.5%, 24.3% vs. 17.2% p = 0.058).


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Endocarditis, Bacterial/epidemiology , Argentina/epidemiology , Incidence , Prevalence , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/microbiology
5.
Rev. argent. microbiol ; 51(2): 136-139, jun. 2019. tab
Article in Spanish | LILACS | ID: biblio-1013362

ABSTRACT

Los bacilos gram negativos (BGN) que no pertenecen al grupo HACEK son una causa infrecuente de endocarditis infecciosa. Los aspectos epidemiológicos, diagnósticos y pronósticos de esta entidad son poco conocidos y la experiencia aún es limitada. Nuestros objetivos fueron analizar las características clínicas y microbiológicas de las endocarditis infecciosas (EI) por BGN no HACEK diagnosticadas en un centro de alta complejidad de Argentina en el período 1998-2016 y conocer su evolución hospitalaria, a fin de compararlas con las EI debidas a otros microorganismos.


Non-HACEK Gram-negative bacilli are a rare cause of infective endocarditis. Epidemiological, diagnostic and prognostic aspects of this entity are little known, and there is limited experience. The aim of this study was to analyze the clinical, microbiological and in-hospital outcomes of non-HACEK Gram negative bacilli endocarditis and to compare them with those due to other microorganisms.


Subject(s)
Gram-Negative Aerobic Rods and Cocci/pathogenicity , Endocarditis, Bacterial/microbiology , Clinical Evolution , Endocarditis, Bacterial/classification , Endocarditis, Bacterial/etiology
6.
Rev. argent. cardiol ; 86(1): 35-41, Feb. 2018.
Article in Spanish | LILACS | ID: biblio-990515

ABSTRACT

RESUMEN: Introducción: Actualmente no hay consenso sobre el manejo anestésico más adecuado en el implante valvular aórtico percutáneo por vía transfemoral. Aunque se ha demostrado la factibilidad de concretar el procedimiento bajo anestesia local con sedación consciente o sin esta, los resultados clínicos reportados son controvertidos. Objetivos: Evaluar la seguridad y eficacia del implante valvular aórtico percutáneo por vía transfemoral realizado bajo anestesia general versus anestesia local con sedación consciente. Material y métodos: Análisis unicéntrico y retrospectivo de los pacientes con estenosis aórtica grave sintomática con alto riesgo quirúrgico sometidos a un implante valvular aórtico percutáneo por vía transfemoral desde marzo de 2009 a diciembre de 2016, según el manejo anestésico. Los desenlaces de seguridad y eficacia fueron evaluados a 30 días según las definiciones del Valve Academic Research Consortium-2. Además, se evaluaron los principales tiempos durante la internación. Resultados: Se incluyeron 121 pacientes (Edad 83,2 ± 5,7 años, hombres 48,8%), tratados con un implante valvular aórtico percutáneo por vía transfemoral bajo anestesia general (n = 55, 45,5%) o anestesia local con sedación consciente (n = 66, 54,5%). No se observaron diferencias significativas en los resultados intraprocedimiento ni en los desenlaces de seguridad y eficacia a 30 días. La mortalidad a 30 días fue del 7,3% en el grupo AG y del 3% en el grupo anestesia local con sedación consciente 3%, p log-rank 0,28 (mortalidad global 5%). La necesidad de conversión a anestesia general se presentó en 2 pacientes (3%), por complicaciones vasculares mayores durante el procedimiento. El grupo anestesia local con sedación consciente presentó menor tiempo total de procedimiento, internación en unidad de cuidados intensivos e internación total. Conclusión: El implante valvular aórtico percutáneo por vía transfemoral realizado bajo anestesia local con sedación consciente, parece ser una alternativa segura y eficaz al uso de anestesia general.


Abstract: Background: Currently, there is no consensus about the most adequate anesthetic management in transfemoral transcatheter aortic valve replacement. Although it has been shown that local anesthesia (LA) with or without conscious sedation is feasible, clinical results are controversial. Objective: The aim of this study was to evaluate the safety and efficacy of transfemoral transcatheter aortic valve replacement performed under general anesthesia versus local anesthesia with conscious sedation. Methods: This was a single-center, retrospective study of high risk patients with severe aortic stenosis undergoing transfemoral transcatheter aortic valve replacement between March 2009 and December 2016. The population was divided according to anesthetic management. Safety and efficacy outcomes were evaluated at 30-days and were classified according to definitions of the Valve Academic Research Consortium-2. In addition, key times during hospitalization were evaluated. Results: A total of 121 patients undergoing transfemoral transcatheter aortic valve replacement under general anesthesia (n=55, 45.5%) or local anesthesia with conscious sedation (n=66, 54.5%). were included in this analysis. Mean age was 83.2±5.7 years and 48.8% were men. There were no differences in either the procedural result or in the 30-day efficacy and safety outcomes. The rate of death at 30-days was 7.3% in the group with general anesthesia and 3% in the local anesthesia with conscious sedation group (log-rank p 0.28). The need of conversion to general anesthesia was 3% (2 patients), in all cases due to major vascular complications during the procedure. In the local anesthesia with conscious sedation group shorter procedural time, intensive care unit and hospital length of stay were observed. Conclusions: Transfemoral transcatheter aortic valve replacement performed under local anesthesia with conscious sedation seems to be a safe and effective alternative to the use of general anesthesia.

7.
Rev. bras. cardiol. invasiva ; 21(4): 319-325, out.-dez. 2013. graf, tab
Article in Portuguese | LILACS | ID: lil-703682

ABSTRACT

INTRODUÇÃO: O procedimento de implante transcateter da válvula aórtica (TAVI, do inglês transcatheter aortic valve implantation) representa opção de tratamento em pacientes com estenose valvar aórtica (EA) com risco cirúrgico elevado ou proibitivo. Relatamos nossa experiência usando o sistema autoexpansível Medtronic CoreValve®. MÉTODOS: No período de 2009 a 2013, 51 pacientes consecutivos com EA grave sintomática e risco cirúrgico alto ou proibitivo foram submetidos ao TAVI. Os resultados foram analisados de acordo com os critérios Valve Academic Research Consortium (VARC) -2. RESULTADOS: A média de idades dos pacientes foi 82 ± 6 anos, 49% eram do sexo feminino, 19% diabéticos, 21% tinham insuficiência renal e o EuroSCORE logístico foi 17,4 ± 11,4%. O sucesso do dispositivo foi alcançado em 84,3%. Todos os pacientes tiveram diminuição significativa dos gradientes transaórticos, que foi mantida ao longo do tempo. A internação hospitalar foi de 6 dias (intervalo interquartil: 5-8,8). A mortalidade intra-hospitalar e aos 30 dias foi 7,8% e 9,8%, respectivamente. Implante de marca-passo permanente foi necessário em 32,6% dos casos; acidente cerebrovascular isquêmico ocorreu em 3,9%; e complicações vasculares maiores em 6% dos pacientes. A sobrevivência aos 6 meses e em 1 ano foi 86,3% e 84,4%, respectivamente. A classe funcional NYHA melhorou significativamente após o TAVI e permaneceu baixa no seguimento de médio prazo. CONCLUSÕES: Nesta experiência preliminar, o tratamento de pacientes com EA e risco cirúrgico alto ou proibitivo com TAVI, usando o sistema autoexpansível CoreValve®, foi considerado viável e seguro, e levou à melhoria sustentável dos sintomas cardíacos. Após a superação dos riscos iniciais de morte e de acidente cerebrovascular, o procedimento garantiu um bom resultado clínico, no longo prazo.


BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a treatment option for patients with aortic valve stenosis (AS) and high or prohibitive surgical risk. We report our experience using the Medtronic CoreValveTM self-expending system. METHODS: From 2009 to 2013, 51 consecutive patients with severe symptomatic AS and high or prohibitive surgical risk were submitted to TAVI. Results were analyzed according to the criteria of the Valve Academic Research Consortium (VARC) -2. RESULTS: Mean age was 82 ± 6 years, 49% were female, 19% were diabetic, 21% had renal failure and the logistic EuroScore was 17.4 ± 11.4%. The success rate of the device was 84.3%. All of the patients had a significant decrease of transaortic gradients, which was maintained over time. Hospitalization time was 6 days (interquartile range: 5-8,8). In-hospital mortality at 30 days was 7.8% and 9.8%, respectively. Permanent pacemaker implantation was required in 32.6% of the cases, ischemic stroke was observed in 3.9% and major vascular complications in 6% of the patients. Survival at 6 months and 1 year was 86.3% and 84.4%, respectively. NYHA functional class improved significantly after TAVI and remained low in the medium-term follow-up. CONCLUSIONS: In this preliminary experience, the treatment of patients with AS and high or prohibitive surgical risk with TAVI, using the CoreValveTM self-expanding system was feasible and safe and led to sustained improvement of cardiac symptoms. After overcoming the initial risks of death and stroke, the procedure guaranteed good long-term clinical outcomes.


Subject(s)
Humans , Male , Female , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/physiopathology , Echocardiography , Risk Factors , Stroke , Treatment Outcome
8.
Rev. argent. cardiol ; 80(4): 310-313, ago. 2012. ilus
Article in Spanish | LILACS | ID: lil-657581

ABSTRACT

El accidente vascular encefálico embólico constituye la complicación más importante de la fibrilación auricular (FA) y el tratamiento anticoagulante es de elección para su prevención. Alrededor del 20% de los pacientes con FA presentan contraindicaciones de anticoagulación (ACO). La orejuela izquierda (OI) se ha identificado como el principal sitio de formación de trombos en la FA, especialmente en pacientes sin enfermedad valvular y sin deterioro de la función ventricular. La oclusión de la OI reduce la incidencia de eventos embólicos en este tipo de pacientes. En esta presentación se describe un caso de cierre percutáneo de la OI, con empleo del dispositivo Amplatzer Cardiac Plug. El paciente tenía riesgo embólico alto y contraindicación absoluta de ACO. El procedimiento se realizó en el Laboratorio de Hemodinamia, bajo guía radioscópica y ecocardiografía transesofágica, con anestesia general; se logró la oclusión completa de la OI. No se presentaron complicaciones durante el procedimiento y luego de un seguimiento de 3 meses, la OI se encuentra totalmente excluida y no se han evidenciado eventos embólicos.


Percutaneous closure of left atrial appendage to prevent thromboembolism in atrial fibrillation Embolic stroke is a major concern in atrial fibrillation (AF), and anticoagulation is the therapy of choice to prevent it. Around 20% of patients with AF have contraindications for anticoagulation (OAC). The left atrial appendage (LAA) has been identified as the most common place of thrombosis in patients with AF, particularly in those with non-valvular AF or impaired ventricular function. LAA occlusion reduces the incidence of embolic events in these patients. This article describes a case of percutaneous closure of LAA with the Amplatzer Cardiac Plug device. The patient was at high risk of embolism and had absolute contraindication for OAC. The procedure was performed at the cardiac catheterization laboratory under fluoroscopic guidance and transesophageal echocardiography, with general anesthesia; complete closure of the LAA was achieved. During the procedure, no complications were reported. The patient remained event-free at three-month follow-up, with complete exclusion of LAA. No embolic events have been reported.

9.
Rev. argent. cardiol ; 79(6): 537-540, dic. 2011. ilus
Article in Spanish | LILACS | ID: lil-639688

ABSTRACT

El desarrollo de fuga paravalvular (FPV) luego del reemplazo valvular mitral es un fenómeno poco frecuente pero de gran repercusión sintomática. Debido a la elevada morbimortalidad de su abordaje quirúrgico se han intentado varias técnicas percutáneas con una tasa éxito que varía entre el 60% y el 90%. En esta presentación se describe el caso de una paciente joven, con múltiples cirugías valvulares mitrales previas, sintomática por disnea limitante y anemia hemolítica. Con el uso de imágenes ecocardiográficas tridimensionales, se realizó la oclusión de la FPV con un dispositivo Amplatzer III, diseñado específicamente para dicha indicación. Luego de un seguimiento de 3 meses, la FPV permanece totalmente excluida y la paciente se encuentra asintomática.


The development of mitral paravalvular leak (PVL) after mitral valve replacement is an uncommon complication with severe symptoms. The surgical repair of this condition has high morbidity and mortality; for this reason, several percutaneous techniques have been attempted with success rates between 60% and 90%. We describe the case of a young female patient with multiple mitral valve surgeries, who presented limiting dyspnea and hemolytic anemia. The PVL was closed using a specially designed Amplatzer III device under three-dimensional echocardiography. After 3 months of follow-up, the PVL remains completely excluded and the patient is asymptomatic.

10.
Rev. argent. cardiol ; 79(4): 314-321, ago. 2011. ilus, graf, tab
Article in Spanish | LILACS | ID: lil-634279

ABSTRACT

Introducción La cirugía de reemplazo valvular aórtico es el tratamiento de elección en pacientes con estenosis aórtica. Sin embargo, en una proporción considerable de pacientes, el riesgo quirúrgico y la presencia de algunas comorbilidades, que aumentan este riesgo, impiden la cirugía. El reemplazo percutáneo de la válvula aórtica representa una alternativa a la cirugía valvular convencional para pacientes seleccionados de riesgo elevado. Objetivo Comunicar la experiencia inicial de reemplazo percutáneo de la válvula aórtica con prótesis autoexpandible CoreValve® (Medtronic, Minneapolis, MN, USA) en pacientes portadores de estenosis aórtica grave. Material y métodos Registro multicéntrico en el que se incluyeron 21 pacientes con estenosis aórtica grave (área < 1 cm²) sintomática y riesgo quirúrgico elevado sometidos a implante percutáneo en cuatro centros cardiovasculares argentinos de alta complejidad. Para el procedimiento se implementó una estrategia multidisciplinaria que involucró a diversos especialistas: anestesiólogo, cirujano, expertos en imágenes y cardiólogos intervencionistas. Resultados La edad media fue de 80,8 ± 7,1 años (rango: 63-90), el 57% de sexo masculino, área valvular media de 0,59 ± 0,25 cm² y EuroSCORE de 18,1% ± 4%. El 73% y el 27% de los pacientes se encontraban en clase funcional III y IV, respectivamente. El éxito del procedimiento fue del 95,2% (20/21), que se tradujo en una reducción pronunciada del gradiente pico transvalvular aórtico (82 ± 14 mm Hg a 12 ± 3 mm Hg; p < 0,001), mientras que el desarrollo posprocedimiento de regurgitación aórtica de grado moderado-grave fue del 14%. El 85,8% de los pacientes evolucionaron a clase funcional I. El requerimiento de marcapasos definitivo fue del 38% (8/21). La mortalidad del procedimiento y a los 30 días fue del 4,7% y del 9,5%, respectivamente; se observó un caso de accidente cerebrovascular isquémico menor con restitución ad integrum dentro de la semana. Se detectaron 4 óbitos en el seguimiento alejado (mediana 7 meses), dos de origen cardíaco (mortalidad cardíaca 19%) y otros dos de causa no cardíaca. Conclusiones El tratamiento de la estenosis aórtica grave en pacientes de riesgo quirúrgico elevado mediante reemplazo valvular percutáneo con prótesis CoreValve® es una alternativa factible que se asocia con una mejoría funcional notoria. La selección adecuada de pacientes, el perfeccionamiento de la técnica del procedimiento y el desarrollo de nuevos diseños incrementarán su eficacia y seguridad.


Background Aortic valve replacement is the treatment of choice in patients with aortic stenosis. However, a significant number of patients are not candidates for surgery due to high surgical risk and to the presence of comorbidities. Percutaneous aortic valve replacement represents an alternative option to conventional aortic valve surgery for selected high risk patients. Objective To inform about the initial experience with percutaneous aortic valve replacement with a self-expanding CoreValve® aortic valve prosthesis (Medtronic, Minneapolis, MN, USA). Material and Methods We conducted a multicenter registry including 21 patients with severe symptomatic aortic stenosis (aortic valve area < 1 cm²) and high surgical risk undergoing percutaneous aortic valve replacement in four high complexity cardiovascular centers. A multidisciplinary strategy was used involving several specialists: anesthesiologist, surgeon, diagnostic images specialists and interventional cardiologists. Results Mean age was 80.8±7.1 years (range: 63-90); 57% were men. Mean aortic valve area was 0.59±0.25 cm² and mean EuroSCORE was 18.1%±4%. The percentages of patients in functional class III and IV were 73% and 27%, respectively. The procedure was successful in 95.2% (20/21) of patients, with a pronounced reduction in peak transvalvular aortic gradient (from 82±14 mm Hg to 12±3 mm Hg; p <0,001); 14% of patients developed moderate to severe aortic regurgi-tation after the procedure. 85.5% of patients evolved to FC I. Definite pacemaker implantation was required in 38% (8/21). Procedure-related mortality was 4.7% and mortality after 30 days was 9.5%. One patient developed a minor stroke with complete recovery within a week. Four patients died in the long-term follow-up (median 7 months): 2 due to cardiac causes (cardiac mortality 19%) and 2 due to non-cardiac causes. Conclusions Percutaneous aortic valve replacement with CoreValve® aortic valve prosthesis is a feasible option for patients with high surgical risk that is associated with significant clinical improvement. The adequate selection of patients, improvement of the surgical technique and the development of new designs will increase the efficacy and safeness of the procedure.

11.
Rev. argent. cardiol ; 79(3): 226-230, jun. 2011. ilus, tab
Article in Spanish | LILACS | ID: lil-634268

ABSTRACT

El infarto de miocardio con coronarias angiográficamente normales tiene una prevalencia de aproximadamente el 7-10%. Muchas veces, el diagnóstico etiológico es dificultoso, y tiene importancia tanto en la clínica como en el pronóstico. El objetivo de nuestro estudio fue mostrar una serie consecutiva de pacientes con diagnóstico inicial de síndrome coronario agudo con elevación de troponina y ausencia de obstrucción arterial coronaria; en los cuales, la RM cardíaca (RMC) orientó al diagnóstico etiológico mediante la caracterización de la lesión miocárdica. Desde enero de 2005 hasta diciembre de 2009 ingresaron 720 pacientes consecutivos, con diagnóstico inicial de síndrome coronario agudo y troponinas positivas, de los cuales, 64 no presentaron lesiones coronarias angiográficamente significativas. A estos pacientes, luego del cateterismo (dentro de las 72 ± 24 hs) se les practicó RMC, realizándose secuencias de cine (b-SSFP) en eje corto, con 2, 3 y 4 cámaras para valorar la motilidad segmentaria, en secuencias potenciadas en T2 e imágenes de realce tardío del miocardio (RTM) con secuencia "inversión-recuperación". De estos pacientes, 39 fueron diagnosticados de miocarditis; 12 con infartos, 8 con síndrome de Takotsubo, 2 con miocardiopatía hipertrófica apical y solo 3 casos quedaron sin diagnóstico. Estos hallazgos ponen de manifiesto la gran utilidad de la RMC en el escenario clínico de síndromes de dolor precordial, ECG no definitivos y troponinas elevadas con arterias angiográficamente normales. La presencia de RTM y su patrón de distribución permiten definir el diagnóstico etiológico y orientar a la interpretación del proceso fisiopatológico.


The prevalence of myocardial infarction with angiographically normal coronary arteries is approximately 7-10%. The etiological diagnosis is sometimes difficult and is important in terms of clinical practice and prognosis. The goal of our study was to show a series of consecutive patients with an initial diagnosis of acute coronary syndrome with high troponin levels and absence of coronary artery obstruction in which cardiac magnetic resonance imaging (CMRI) gave a description of the myocardial lesion, orientating towards the etiological diagnosis. From January 2005 to December 2009, 720 consecutive patients with an initial diagnosis of acute coronary syndrome and elevated troponins were included; 64 of these patients did not present angiographically significant coronary artery stenosis. Within 72 ± 24 h after coronary angiography, these patients underwent CMRI using b-SSFP sequences for cine imaging in short-axis, 2-, 3- and 4- chamber views for the evaluation of segmental wall motion, with T2-weighted and delayed enhancement (DE) images of the myocardium with an "inversion-recovery" sequence. The following diagnoses were made: myocarditis (39 patients); myocardial infarction (12 patients); Tako-Tsubo syndrome (8 patients); apical hypertrophic cardiomyopathy (2 patients); 3 patients remained without diagnosis. These findings demonstrate the usefulness of CMRI in the clinical scenario of patients with chest pain, inconclusive ECG findings and high troponin levels with angiographically normal coronary arteries. The presence and distribution pattern of DE make it possible to define the etiological diagnosis and interpret the physiopathological process.

13.
Insuf. card ; 5(2): 97-101, abr.-jun. 2010. ilus, tab
Article in Spanish | LILACS | ID: lil-633373

ABSTRACT

Se presenta el caso de una paciente de 36 años de edad que consulta por presentar palpitaciones y disnea de esfuerzo, diagnosticándose una insuficiencia cardíaca debida a una miocardiopatía no compactada y severo deterioro de la función sistólica ventricular izquierda. Ante la falta de mejoría a pesar del tratamiento médico máximo tolerado, se decide la colocación de un cardiodesfibrilador implantable con resincronizador. Al año de la colocación del dispositivo, la paciente se encuentra asintomática con franca mejoría de los parámetros ecocardiográficos.


We present a case of a 36 years-old female patient who presents palpitations and dyspnea, with heart failure due to non-compacted cardiomyopathy and severe left ventricular systolic deterioration. Due to the absence of improvement instead of full medical tolerated treatment, we decided to install cardiac resynchronization therapy device with an implantable cardioverter defibrillator device. One year after placement of the device, the patient is asymptomatic with clear improvement of echocardiographic parameters.


Nós relatamos o caso de uma paciente de 36 anos de idade, com palpitações e dispnéia, e o diagnóstico de insuficiência cardíaca por cardiomiopatia não-compactada e comprometimento grave da função sistólica do ventrículo esquerdo. Decidiu-se a colocação de um desfibrilador cardioversor implantável com terapia de ressincronização. Um ano após a colocação do aparelho, o paciente fica assintomática, com melhora dos parâmetros ecocardiográficos.

14.
Rev. argent. cardiol ; 77(3): 203-207, mayo-jun. 2009. ilus
Article in Spanish | LILACS | ID: lil-634084

ABSTRACT

Una proporción importante de pacientes con estenosis aórtica (EAo) grave poseen comorbilidades que incrementan el riesgo de la cirugía de reemplazo valvular aórtico. El implante percutáneo de válvula protésica surge como una alternativa en este grupo de pacientes. Se comunican dos casos de pacientes de edad avanzada portadores de EAo grave a los que se les realizó con éxito el implante percutáneo de una prótesis valvular aórtica CoreValve y se describen los criterios para la selección de pacientes y la técnica de implante percutáneo.


A significant proportion of patients with severe aortic stenosis (AS) have comorbidities that increase the risk of surgical aortic valve replacement. Percutaneous implantation of an aortic valve prosthesis emerges as an alternative in this group of patients. We report two cases of elderly patients with severe aortic stenosis that underwent successful percutaneous implantation of CoreValve aortic valve prostheses; in addition, criteria for patient selection and the technique of the procedure are described.

15.
Rev. argent. cardiol ; 76(6): 488-490, nov.-dic. 2008. ilus
Article in Spanish | LILACS | ID: lil-634045

ABSTRACT

La miocardiopatía hipertrófica apical es una entidad que se caracteriza por la presencia de hipertrofia predominante de los segmentos apicales del ventrículo izquierdo. Esta forma de miocardiopatía hipertrófica en general presenta una evolución clínica y un pronóstico benignos. Sin embargo, la típica presencia de alteraciones significativas del electrocardiograma puede simular la existencia de enfermedad coronaria, motivo por el cual el diagnóstico definitivo por técnicas de imagen tiene una gran implicación clínica. En esta presentación se describe un caso de miocardiopatía hipertrófica apical en el contexto de dolor precordial y dificultades diagnósticas, en el que se demuestran las ventajas de la ecocardiografía tridimensional para su evaluación.


Apical hypertrophic myocardiopathy is characterized by the presence of hypertrophy localized to the left ventricular apex. This type of hypertrophic myocardiopathy usually presents favorable clinical outcomes and a benign prognosis. Nevertheless, the typical presence of significant alterations in the electrocardiogram may mimic the existence of coronary artery disease. In this sense, image tests have great clinical implications to arrive at a definite diagnosis. We present a case report of apical hypertrophic myocardiopathy in a context of chest pain and difficulties to perform a diagnosis; the advantages of three-dimensional echocardiography for the assessment of this disorder are described.

SELECTION OF CITATIONS
SEARCH DETAIL