Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Rev. Hosp. Clin. Fac. Med. Univ. Säo Paulo ; 54(6): 181-6, Nov.-Dec. 1999. ilus, tab, graf
Article in English | LILACS | ID: lil-260494

ABSTRACT

Cylindrical specimens of bone measuring 15 mm in diameter were obtained from the lateral cortical layer of 10 pairs of femurs and tibias. A central hole 3.2 mm in diameter was drilled in each specimen. The hole was tapped, and a 4.5 mm cortical bone screw was inserted from the outer surface. The montage was submitted to push-out testing up to a complete strip of the bone threads. The cortical thickness and rupture load were measured, and the shear stress was calculated. The results were grouped according to the bone segment from which the specimen was obtained. The results showed that bone cortex screw holding power is dependent on the bone site. Additionally, the diaphyseal cortical bone tissue is both quantitatively and qualitatively more resistant to screw extraction than the metaphyseal tissue.


Subject(s)
Bone Screws , Femur/physiology , Tibia/physiology , Diaphyses/injuries , Diaphyses/surgery , Femur/injuries , Femur/surgery , Tensile Strength , Tibia/injuries , Tibia/surgery
2.
Rev. bras. ortop ; 32(8): 611-4, ago. 1997. ilus, graf
Article in Portuguese | LILACS | ID: lil-196863

ABSTRACT

Compararam-se a rigidez axial e a estabilidade radial do fixador externo circular na montagem "clássica" preconizada por Ilizarov, utilizando apenas fios finos tensionados e, nas variaçöes propostas pela escola de Lecco, utilizando fios finos tensionados e pinos de Schanz, e por Green (Rancho de Los Amigos - EUA), utilizando apenas pinos de Schanz, através de ensaios de flexo-compressäo (compressäo excêntrica). Todas as montagens utilizaram quatro anéis circulares de aço inoxidável de 150mm, dois em cada lado do espaço que simulava perda óssea (situaçäo de insatabilidade). Foram utilizados fios de Kirscgner de 1,8mm de diâmetro e pinos de Schanz de 4,8mm de diâmetro. No centro das extremidades confrontantes dos tubos, passando pelo eixo da montagem, foram colocados ponteiros de metal como pontos de referência. O modelo adotado simula fratura de alta energia na regiäo diafisária do terço médio da tíbia com 2 cm de perda de substância óssea. As montagens foram instaladas em máquinas universais de ensaios mecânicos, provida de célula de carga eletrônica e de registrador gráfico. A carga aplicada através de um pino excêntrico de extremidade esférica polida situado a 25mm do eixo do sistema, em posiçäo que se convencionou dorsal, a fim de gerar momentos que se assemelham aos da tíbia humana durante a fase de apoio da marcha (toque calcâneo). Conclui-se que, axialmente, a montagem "clássica" é a mais elástica das três, enquanto a montagem norte-americana (Rancho) é a mais rígida e que as três montagens têm a mesma rigidez no sentido radial do foco de fratura


Subject(s)
Humans , External Fixators , Fracture Fixation/methods , Ilizarov Technique/instrumentation , Tibia
3.
Rev. bras. ortop ; 29(6): 431-6, jun. 1994. ilus, tab
Article in Portuguese | LILACS | ID: lil-199721

ABSTRACT

Os autores estudaram experimentalmente 48 metacarpianos humanos frescos submetidos a teste de flexäo simples biapoiado. Realizaram medidas antropométricas (comprimento, peso, área, diâmetro interno e externo) distribuídos em grupo A (segundo e terceiro metacarpianos) e grupo B (quarto e quinto metacarpianos) por apresentarem uma distribuiçäo de valores semelhantes. Analisaram estes valores pelo teste de Wilcoxon e verificaram que para todos os parâmetros estudados (com exceçäo do diâmetro interno), o grupo A apresentou diferença estatisticamente significante. Na fase seguinte, realizaram os testes de flexäo e determinaram os valores da carga e deformaçäo no limite de proporcionalidade e no limite de resistência e a constante de proporcionalidade. Analisaram estes valores também pelo teste de Wilcoxon e foram observadas diferenças estatisticamente significantes entre os dois grupos, para todos estes parâmetros estudados.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Metacarpus/anatomy & histology , Cadaver , Dissection
4.
Rev. bras. ortop ; 29(4): 211-7, abr. 1994. ilus, tab
Article in Portuguese | LILACS | ID: lil-203421

ABSTRACT

Os autores estudaram experimentalmente cinco modelos de osteossíntese, [1) placas e parfusos; 2) duas cerclagens intra-ósseas perpendiculares; 3) dois fios de Kirschner associados à cerclagem em oito; 4) dois fios de Kirschner cruzados; 5) dois fios de Kirschner associados à cerclagem externa] e um grupo controle (6), realizadas em metacarpianos humanos secos submetidos à força de flexäo. Concluíram que o tipo de ostessíntese mais rígida foi o do grupo 1 (placas e parafusos dorsais) e que o grupo 4 (dois fios de Kirschner cruzados) foi o que teve o pior desempenho global.


Subject(s)
Humans , Fracture Fixation, Internal/methods , Metacarpus/surgery , Cadaver , Metacarpus/injuries , Tensile Strength
5.
Rev. bras. ortop ; 29(4): 221-5, abr. 1994. tab, ilus
Article in Portuguese | LILACS | ID: lil-203423

ABSTRACT

Os autores estudaram experimentalmente 26 ossos semilunares de 13 cadáveres frescos, analisando medidas antropométricas e submetendo-os a ensaios de compressäo para verificar sua resistência. Obtiveram valores de resistência variando de 41 a 200kgf, com média de 102,1kgf, e correlacionaram com as medidas antropomêtricas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Lunate Bone/physiology , Cadaver , Compressive Strength , Lunate Bone/anatomy & histology
6.
Rev. bras. ortop ; 28(3): 167-71, mar. 1993. ilus, tab
Article in Portuguese | LILACS | ID: lil-197169

ABSTRACT

A fim de verificar a possibilidade de aplicaçao do compósito de hidroxiapatita-polimetilmetacrilato (HA-BOND-40/0) como material de enxerto, foram realizados testes comparativos de compressao axial em dez corpos de prova cilíndricos à base de compósito e dez de polimetilmetacrilato puro (controle). Todos os corpos foram imersos em soro fisiológico durante 48 horas, exceto dois corpos de compósito, mantidos secos. O compósito apresentou resistência, elasticidade e regidez significantemente menores que o cimento acrílico. Observou-se interferência da soluçao fisiológica em suas propriedades. Os autores concluem que o compósito de hidroxiapatita-polimetilmetacrilato nao deveria ser utilizado em casos de solicitaçao mecânica elevada.


Subject(s)
Bone Transplantation , Composite Resins , Hydroxyapatites , Compressive Strength , Evaluation Study , Quality Control
7.
Rev. paul. med ; 110(2): 63-8, mar.-apr. 1992. ilus, tab
Article in English | LILACS | ID: lil-122168

ABSTRACT

The present study was designed to assess the effects of nutrition on fracture healing in a controlled animal model. Tibial fractures were studied in 115 Wistar rats divided into four groups: group 1,50 control animals kept on a normal diet; groups 2 and 3,45 protein-deprived animals, and group 4,20 animals submitted to protein malnutrition before the fracture and then placed on a normal laboratory diet. The parameters evaluated during the study were: variation in animal weight during the experiment ( confirmation of protein malnutrition), fracture healing as determined by bone callus radiology, macroscopic evaluation of bone callus mechanical resistance, and histological fracture examination by common light microscopy after staining with hematoxylin-eosin. The results showed the beneficial effects of protein nutrition support on the healing of long bone fractures. Callus formation was significantly improved in groups 1 and 4 compared to groups 2 and 3. In groups 1 and 4, callus development was normal, with regular bone tissue formation, whereas in groups 2 and 3 ther was a large aamount of fibrous-connective tissue with scarce formation of osseous tissue


Subject(s)
Animals , Male , Female , Rats , Fracture Healing , Fractures, Closed , Protein Deficiency , Tibial Fractures , Case-Control Studies , Rats, Wistar
9.
Rev. bras. ortop ; 26(6): 201-4, jun. 1991. ilus, tab
Article in Portuguese | LILACS | ID: lil-116136

ABSTRACT

Os autores estudaram em modelo experimental, em vertebras de cäes, a funçäo dos ligamentos alares e transverso na estabilidade entre o atlas e o áxis. Com base nos testes biomecânicos realizados, concluem que a resistência dos ligamentos alares e transverso säo equivalentes e proporcionais e que a ruptura do ligamento transverso só foi obtida nos ensaios em flexocompressäo, enquanto que a ruptura dos alares foi obtida em todos os mecanismos simulados


Subject(s)
Animals , Dogs , Ligaments/physiology , Cervical Vertebrae/injuries , Atlas , Axis, Cervical Vertebra , Rupture , Tensile Strength
10.
Rev. bras. ortop ; 26(5): 157-60, maio 1991. ilus, tab
Article in Portuguese | LILACS | ID: lil-116144

ABSTRACT

Foram testados oito acetábulos de cadáveres frescos, comparando-se sua resistência frente à força axial, com utilizaçäo de rede metálica em apenas quatro acetábulos. Houve aumento significativo da resistência no conjunto que empregou rede metálica


Subject(s)
Humans , Male , Adult , Middle Aged , Acetabulum/surgery , Surgical Mesh , Aged, 80 and over , Stainless Steel , Stress, Mechanical
11.
Rev. bras. ortop ; 25(11/12): 395-8, nov.-dez. 1990. tab
Article in Portuguese | LILACS | ID: lil-92507

ABSTRACT

Os autores estudaram experimentalmente, em vértebras de cäes, a resistência dos complexos anterior, médio e posterior do segmento toracolombar da coluna à traçäo. Concluem que o complexo ligamentar anterior foi o mais resistente, vindo a seguir o complexo ligamentar médio


Subject(s)
Dogs , Animals , Male , Female , Spine , Traction , Biomechanical Phenomena , Cervical Vertebrae , Ligaments
12.
Rev. bras. ortop ; 25(10): 373-6, out. 1990. tab
Article in Portuguese | LILACS | ID: lil-92501

ABSTRACT

Foi analisado o comportamento dos anéis do aparelho Ilizarov com 130, 160 e 200mm de diâmetro sob carga de compressäo, montado com fios de Kirschner de 1,5mm, com e sem tensäo, dobrados ou näo, e sobre três ou quatro apoios. Observou-se perda da estabilidade em anéis de maior diâmetro e em anéis sobre três apoios. O dobramento da extremidade dos fios näo melhorou a fixaçäo, mas permitiu identificar o início do escorregamento. Observou-se também comportamento diferente da fixaçäo dos fios nos parafusos com orifício central e fenda lateral


Subject(s)
Bone Lengthening/instrumentation , Bone Wires , Tensile Strength
13.
Rev. bras. ortop ; 25(7): 243-7, jul. 1990. ilus, tab
Article in Portuguese | LILACS | ID: lil-129236

ABSTRACT

Com o objetivo de se determinar a resistência das diversas regiöes da superfície articular, estudaram-se 15 joelhos de cadáveres frescos. Foram feitos ensaios de penetraçäo em sete diferentes pontos confrontantes da tíbia e do fêmur. Os resultados mostraram que a resistência do côndilo medial da tíbia é a maior, enquanto a do côndilo lateral é a menor. No fêmur isso näo foi observado; entretanto, a média de resistência da tíbia é igual à do fêmur e a profundidade da camada esponjosa é mais fina e superficial na tíbia que no fêmur


Subject(s)
Humans , Adult , Middle Aged , Femur/physiology , Tensile Strength , Tibia/physiology , Knee Joint/physiology
14.
Rev. bras. ortop ; 25(6): 197-201, jun. 1990. ilus, tab
Article in Portuguese | LILACS | ID: lil-127383

ABSTRACT

Pelo estudo de 20 joelhos de cadáveres frescos determinou-se näo haver proporcionalidade entre as características mecânicas do ligamento cruzado anterior e do terço central do tendäo patelar. A resistência do ligamento cruzado anterior é proporcional ao tamanho do joelho e o mesmo näo acontece com a porçäo central do tendäo patelar. A resistência das estruturas estudadas näo se altera com a idade. Outros parâmetros foram estuddos e inter-relacionados


Subject(s)
Humans , Male , Female , Anterior Cruciate Ligament/physiology , Patellar Ligament/physiology , Biomechanical Phenomena , Regression Analysis
15.
Folha méd ; 100(5/6): 165-70, maio-jun. 1990. ilus, tab
Article in Portuguese | LILACS | ID: lil-113499

ABSTRACT

Em 96 metacarpianos de cadáveres frescos, foram comparados experimentalmente três modelos de osteossíntese, (1) cerclagens intra-ósseas perpendiculares, (2) dois fios de Kirschner rosqueados cruzados e (3) dois fios de Kirschner lisos cruzados. Para a análise dos resultados foram agrupados em dois conjuntos: 2§ e 3§ metacarpianos e 4§ e 5§ metacarpianos. Estudados os valores da carga no limite de proporcionalidade, observou-se que a síntese 2 (dois fios de Kirschner rosqueados cruzados) é mais resistente que a síntese 3 (dois fios de Kirschner lisos cruzados). Analisaram-se também os valores da constante de proporcionalidade, verificando-se que a síntese 1 (cerclagens intra-ósseas perpendiculares) é mais rígida do que as sínteses 2 e 3


Subject(s)
Humans , Fracture Fixation, Internal/methods , Metacarpus/injuries , Bone Wires
16.
Rev. bras. ortop ; 25(1/2): 26-30, jan.-fev. 1990. ilus, tab
Article in Portuguese | LILACS | ID: lil-85291

ABSTRACT

Estudamos a variaçäo das propriedades físico-mecânicas: resistência a deformaçäo, área de secçäo, densidade óssea e suas interdependências ao longo da diáfise da ulna humana, quando submetida a ensaios de compressäo axial. A resistência óssea variou ao longo do comprimento da ulna, ao contrário da deformaçäo, que se manteve constante. A tensäo máxima média da diáfise ulnar fresca foi de 1.511Kgf/cm**2


Subject(s)
Adult , Humans , Ulna , Tensile Strength
17.
Rev. bras. ortop ; 24(11/12): 393-6, nov.-dez. 1989. ilus, tab
Article in Portuguese | LILACS | ID: lil-129212

ABSTRACT

Os autores apresentam os resultados de 21 casos de hálux valgo tratados pela técnica de Wilson e analisam a influência do ângulo da osteotomia, os ângulos pré e pós-operatórios, metatarsofalangiano do halúx e intermetatarso do I e II raios. Concluem preconizando um ângulo de osteotomia sempre menor que 45º


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Hallux Valgus/surgery , Osteotomy , Hallux Valgus
18.
Rev. bras. ortop ; 24(9): 327-9, set. 1989. ilus
Article in Portuguese | LILACS | ID: lil-83714

ABSTRACT

Os autores realizaram estudo experimental da estabilidade do segmento toracolombar da coluna. Foram utilizadas 15 colunas obtidas de cadáveres frescos, sendo testados os segmentos de T11 a L2. Após teste mecânico, concluiu-se que as fraturas com encunhamento maior que 40% devem ser consideradas instáveis


Subject(s)
Adolescent , Adult , Humans , Male , Autopsy , Dissection , Ligaments, Articular , Spine/anatomy & histology , Clinical Trials as Topic
19.
Rev. bras. ortop ; 24(5): 139-44, 1989. ilus, tab
Article in Portuguese | LILACS | ID: lil-80075

ABSTRACT

Estudamos comparativamente as propriedades mecânicas de quatro grupos de pericárdios bovinos: fresco, congelado e dois tipos fixados em glutaraldeído e conservados em formaldeído obtidos comercialmente. Verficamos a possibilidade de eventual utilizaçäo como substituto biológico de ligamentos e tendöes. Há evidências de que os tratamentos químicos a que säo submetidos os pericárdios comerciais melhoram suas qualidades mecânicas


Subject(s)
Cattle , Animals , Biomechanical Phenomena , Bioprosthesis , Pericardium/physiology , Elasticity , Formaldehyde , Freezing , Glutaral
20.
Rev. bras. ortop ; 23(8): 235-8, ago. 1988. ilus, tab
Article in Portuguese | LILACS | ID: lil-68954

ABSTRACT

Os autores comparam, através de modelo experimental em vértebras da cäes, o comportamento mecânico da substituiçäo do corpo vertebral por cilindros de metilmetacrilato simples e com fio metálico rosqueado no seu eixo longitudinal. Concluem que ambos os modelos testados atendem às cargas de compressäo axial, sendo que o modelo com fio metálico rosqueado é mais estável


Subject(s)
Dogs , Animals , Methylmethacrylates , Cervical Vertebrae/surgery , Biomechanical Phenomena , Models, Biological
SELECTION OF CITATIONS
SEARCH DETAIL