Journal of Biomedical Engineering ; (6): 115-117, 2004.
Article in Chinese | WPRIM | ID: wpr-291170

ABSTRACT

A method for improving the biocompatibility of the intraocular lens (IOL) and reducing the cell attachment was adopted in this study. The alpha-Allyl glucoside was used for the surface modification of the poly methyl methacrylate (PMMA) IOL by way of plasma-induced in situ polymerization. The surfaces of the control and treatment IOLs were characterized by contact angle estimation and ESCA techniques. The resolution, diopter and anti-fatigue of loops were determined by physical and optical methods. Cell attachment on the surfaces was examined by light microscopy. The results indicated that all of the treatment groups had excellent physical and optical properties. The modification with the use of alpha-Allyl glucoside could improve the hydrophilicity of the anterior surface of the PMMA IOLs and reduce the cell attachment.


Subject(s)
Allyl Compounds , Chemistry , Biocompatible Materials , Glucosides , Chemistry , Lenses, Intraocular , Materials Testing , Polymerization , Polymethyl Methacrylate , Chemistry , Surface Properties