1.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 52-55, 2020.
Article in Chinese | WPRIM | ID: wpr-798639

ABSTRACT

Objective@#To establish a method for the determination of 1-methoxy-2-propanol in urine using headspace solid phase micro-extraction coupled with gas chromatography.@*Methods@#The 1-methoxy-2-propanol was enriched by headspace solid phase micro-extraction fiber coated with carbene/polydimethylsiloxane (CAR/PDMS) . Single factor rotation method was used to optimize the conditions of extraction temperature, salt amount, and extraction time. The separation was performed on DB-5 (30 m×0.32 mm×0.25 μm) capillary column and detected with flame ionization detector. The quantification was based on the standard curve.@*Results@#The concentration of 1-methoxy-2-propanol in urine was linear in the range of 0.50-10.0 mg/L, and the linear correlation coefficient was 0.9993. The detection limit of the method was 0.14 mg/L, and the limit of quantification was 0.45 mg/L. The recovery was 85.8% to 104.7%, and the RSD of intra- and inter-batch precision were 3.25%-6.65% and 0.81%-3.96%, respectively.@*Conclusion@#The method is high sensitivity and simple operation, and is suitable for the determination of 1-methoxy-2-propanol in urine of occupational exposure population.

2.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 543-546, 2019.
Article in Chinese | WPRIM | ID: wpr-805598

ABSTRACT

Objective@#To establish a method for determining cyclohexanol in urine by headspace solid-phase microextraction (HS/SPME) coupled with gas chromatography (GC) .@*Methods@#After the urine sample was hydrolyzed by β-glucuronidase, 2.0 g of NaCl was added, then the analyte in urine was adsorbed by a CAR/PDMS solid phase micro-extraction head in a water bath at 50 ℃ for 20 min. And the extraction head was inserted into the gas chromatograph gasification chamber to desorb, the analyte was detected after separated by the capillary through the flame ionization detector.@*Results@#The linear range of the method was 0.1-5.0 mg/L with the correlation coefficients (r) 0.999. The average recovery was 84.5%-96.3%, the inter-day precision was 3.81%-6.00%, and the detection limit was 0.03 mg/L.@*Conclusion@#The method is founded to be low detection limit, simple operation and no need of organic solvent. So it is suitable for the detection of cyclohexanol in urine of occupational exposure to cyclohexanone.

SELECTION OF CITATIONS
SEARCH DETAIL