Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Braz. dent. j ; 31(2): 127-134, Mar.-Apr. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132279

ABSTRACT

Abstract The aim of this study was to assess the internal and vertical marginal fit of metallic copings to abutments and the fracture strength of different narrow diameter dental implant/abutments, either submitted to thermomechanical cycling or not. Sixty-four implant/abutments (n=16) were divided into 4 groups according to diameter and abutment type: G3.5-UAC (morse taper implant Ø3.5mm + universal abutment with beveled chamfer finish); G2.9-UAS (morse taper implant Ø2.9mm + universal abutment with shoulder finish); G2.8-AA (morse taper friction implant Ø2.8mm + anatomical abutment) and G2.5-HP (one-piece implant Ø2.5mm with indexed hexagonal platform). Each group was divided into two subgroups (n=8): submitted and not submitted to thermomechanical cycling (TMC). To assess internal and vertical marginal fit of metallic copings, the assemblies were scanned using microtomography (micro-CT) (n=5). The samples were subjected to the compressive strength test on a universal test machine. Group G3.5-UAC showed the highest marginal misfit regardless of TMC (p<0.05). All other groups were similar after TMC. Group G2.8-AA showed the lowest internal misfit both with and without TMC (p<0.05). Group G2.8-AA showed the highest fracture strength, similar only to G2.5-HP without TMC and G3.5-UAC with TMC. The type of abutment affects the internal and marginal fit of metallic copings and the anatomical abutment led to the best internal and marginal coping fit. The narrow diameter dental implant/abutments differ in terms of fracture strength, the strongest assembly was that composed by implant of type V grade titanium without internal threads (friction implant).


Resumo O objetivo deste estudo foi avaliar a adaptação marginal e interna de cópings metálicos em pilares sobre implantes, e a resistência a fratura de diferentes conjuntos de implantes/pilares de diâmetro reduzido, submetidos à ciclagem termomecânica ou não. Sessenta e quatro implantes/pilares (n=16) foram divididos em 04 grupos de acordo com o tipo de pilar e diâmetro do implante: G3.5-UAC (implante cone morse Ø3.5mm + munhão universal com término em chanfro); G2.9-UAS (implante cone morse Ø2.9mm + munhão universal com término em ombro); G2.8-AA (implante cone morse friccional Ø2.8mm + munhão anatômico); e G2.5-HP (implante de corpo único de Ø2.5mm com plataforma hexagonal indexada). Cada grupo foi dividio em dois subgrupos (n=8): submetidos ou não à ciclagem termomecânica (TMC). As amostras foram escaneadas por microtomografia (micro-CT) para avaliar a adaptação interna e marginal vertical dos copings metálicos. As amostras foram submetidas à resistência à compressão em uma maquina de ensaios universal. O grupo G3.5-UAC apresentou os maiores valores de desadaptação marginal independentemente da TMC (p<0,05). Todos os outros grupos foram similares entre si após TMC. O grupo G2.8-AA demonstrou o menor desajuste interno independentemente de TMC (p<0,05). O grupo G2.8-AA demonstrou a maior resistência à fratura, similar apenas ao grupo G2.5-HP sem TMC e G3.5-UAC com TMC. O tipo de pilar influencia a adaptação interna e marginal vertical de copings metálicos. O grupo do pilar anatômico (sem entalhes na superfície) levou à melhor adaptação, enquanto o grupo com plataforma expandida hexagonal e os grupos com munhão universal (com entalhes na superfície) proporcionaram os maiores desajustes (especialmente com termino em chanfro). Os implantes/pilares de diâmetro reduzido diferem em termos de resistencia à fratura, sendo que o conjunto mais resistente foi aquele composto por titânio tipo V e sem roscas internas (implante friccional).


Subject(s)
Dental Implants , Titanium , Zirconium , Materials Testing , Dental Abutments , Dental Stress Analysis , Dental Implant-Abutment Design , Flexural Strength
2.
Full dent. sci ; 4(13): 78-82, out.-dez. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-681677

ABSTRACT

Nos planejamentos cirúrgicos para a Implantodontia, diferentes abordagens terapêuticas são possíveis para o tratamento dos defeitos ósseos, quando relacionados a defeitos em espessura. Porém, quando nos deparamos com defeitos verticais, a resolução torna-se mais complexa, uma vez que as técnicas aposicionais de enxertia são deficientes para o ganho ósseo vertical. Para tanto, a utilização da técnica de osteotomias segmentares seguida de enxertos de interposição fornece previsibilidade e segurança clínica. Com o objetivo de demonstrar essa técnica, apresenta-se um caso clínico de osteotomia segmentar seguida de enxerto interposicional com hidroxiapatita sintética reabsorvível na região anterior da maxila


In planning for surgical implants, some therapeutic approaches are possible for treating bone defects in thickness. However, when facing vertical defects, the resolution becomes more complex, since appositional grafting techniques are deficient for vertical bone gain. Therefore, using the technique of segmental osteotomies followed by interposition grafts provides predictable and clinically safe resolution. To demonstrate this technique, this paper presents a case of segmental osteotomy followed by interpositional graft with resorbable synthetic hydroxyapatite in the anterior maxilla


Subject(s)
Humans , Female , Middle Aged , Alveolar Ridge Augmentation/methods , Alveolar Ridge Augmentation , Bone Regeneration , Dental Implants , Osteogenesis/physiology , Bone Resorption/diagnosis , Bone Resorption/etiology , Bone Resorption , Guided Tissue Regeneration/methods , Guided Tissue Regeneration
3.
RFO UPF ; 10(2): 67-70, jul.-dez. 2005. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-442593

ABSTRACT

O objetivo da pesquisa foi comparar e correlacionar os níveis de cinza dos pinos intra-radiculares de fibra de vidro Fibrekor Post® (jeneric/Pentron) com a dentina radicular por meio dos sistemas digital Digora® e DentScan DentView®. A coroa de 22 incisivos centrais superiores foi secionada; os condutos radiculares, obturados pela técnica convencional e posteriormente preparados para receber os pinos de fibras de vidro com frequesas de 1,5mm de diâmetro do kit Fibrekor Post®. Foram realizados três sequências radiográficas, com filmes periapicais n 2 Ultraspeed® da Kodak, dos pinos no inteior do conduto e da dentina radicular, com técnica padronizada. As radiografias foram digitalizadas e os valores dos níveis de cinza foram obtidos pelas ferramentas dos sistemas digitais Digora® e DentScan DentView®, sendo posteriormente submetidos aos testes estatatístico t-student e de correlação de Pearson para uma probabilidade de erro de 1 por cento. Verificou-se que os valores médios dos níveis de cinza dos pinos nos interior dos condutos foram: 146,71 no sistema Digora® e 199,50 no sistema DentScan DentView®. Esses valores mostraram-se superiores aos da dentina radicular mesial e distal nos dois sistemas digitais. os níveis de cinza obtidos no sistema Digora® apresentaram um coeficiente de correlaçoa de Pearson positivo em relação ao DentScan DentView®. Conclui-se que os pinos de fibra de vidro Fibrekor Post® com 1,5 mm de diâmetro apresentaram uma imagem radiopaca no interior dos condutos radiculares dos incisivos centrais superiores


Subject(s)
Humans , Male , Female , Dental Materials , Dental Pins , Dental Restoration, Permanent , Dentin , Diagnostic Imaging , In Vitro Techniques , Radiographic Image Enhancement
4.
Rev. odonto ciênc ; 19(44): 131-138, abr.-jun. 2004. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-397028

ABSTRACT

Objetivos: Analisar os níveis de cinza de pinos intrarradiculares de quartzo em radiografias digitalizados com filmes de diferentes sensibilidades. Metodologia: Foram selecionados 22 incisivos centrais superiores, que tiveram suas coroas seccionadas, seu canais tratados e preparados para receber o pino pré-fabricado Light-PostDT número 1. Após a verificação radiográfica da correta execução dos passos anteriores, radiografou-se o pino dentro do conduto dos espécimes com três incidências para cada amostra; este procedimento foi realizado com dois filmes de diferentes sensibilidades, com o tempo de exposição de 0,43 s para o InSight e 0,9 s para o Ultra-speed. Posteriormente foram feitas as digitalizações das imagens para leitura ótica das mesmas no programa Digora (Soderex). Resultados: O nível médio de cinza para o filme Ultra-speed dos pinos no interior de conduto foi de 249,35 e para dentina adjacente foi de 225,43; já no filme InSight o nível médio de cinza dos pinos no interior do conduto foi de 242,90e para dentina adjacente foi de 212,10. Ambos para um nível de significância de 1 por cento (p=0,010). Conclusão: Através do teste de comparação de médias pareadas t-Student, verificou-se que não houve diferença estatisticamente significante nos níveis de cinza entre as dentinas mesial e distal para ambos os filmes; já o pino apareceu com os níveis de cinza significantemente superiores à dentina adjacente. O filme InSight mostrou densidade óptica inferior no pino e na dentina adjacente com relação ao filme Ultra-speed


Subject(s)
Diagnostic Imaging , In Vitro Techniques , Dental Pins , Radiography, Dental, Digital , Dental Restoration, Permanent
5.
Rev. odonto ciênc ; 16(34): 264-267, set.-dez. 2001.
Article in Portuguese | LILACS, BBO | ID: lil-329142

ABSTRACT

Esta revisäo teve a finalidade de comparar as vantagens e as desvantagens do uso das tomografias lineares e computadorizadas


Subject(s)
Tomography , Radiography, Dental, Digital
SELECTION OF CITATIONS
SEARCH DETAIL