Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
DMJ-Dohuk Medical Journal. 2008; 2 (1): 5-16
in English | IMEMR | ID: emr-86151

ABSTRACT

Depression found to be common after acute myocardial infarction AMI, its recognition and treatment may be important to reduce its consequences. To clarify the effect of depression following AMI. Prospective study was conducted at the coronary care unit [CCU] at Ibn-Sena, Mosul teaching hospital. Two hundred cases with AMI ages 25 years up to 75 years were included. Depression was prevalent after AMI, with a higher incidence in females, 57% vs 43% for males. P value < 0.05 and odds ratio: 2.85, this study found that higher percentage of depression was among those with low educational and socioeconomic state and discovered that patients with depression following AMI developed more cardiac complications such as recurrent angina, recurrent AMI, arrhythmia, congestive cardiac failure [CCF] and death more than non depressed patients, 38% of the depressed group needed coronary angiogram vs 23% of non depressed. Patients who developed depression following [AMI] are more prone to complications


Subject(s)
Humans , Male , Female , Depression/etiology , Depression/epidemiology , Myocardial Infarction/psychology , Prospective Studies
2.
Jordan Medical Journal. 1985; 19 (1): 27-33
in English | IMEMR | ID: emr-5800

ABSTRACT

This study was simply done to show the outcome of temporary pacing, which has been done in this part of the world and its comparison with other authors work. Out of 1000 admissions to the Coronary Care Unit, General Hospital, Mosul, 40 patients were considered for temporary pacing. Ten died before pacing, and 30 patients were paced [Table I]. The benefit was obvious in idiopathic complete heart block. The mortality was 15 percent in complete heart block following inferior myocardial infarction. The beneft was doubtful in complete heart block following anterior myocadial infarction where the mortality rate was 57 percent. Early efforts to control heart beats electrically by direct cardiac stimulation date back to the 19th century, when Aldini tried to stimulate the arrested heart of decapitated criminals by means of galvanic stimulation[1]. An important milestone in this field was achieved by Hymen, who observed that the intracardiac injection of diverse substances was capable of restoring heart beats in the arrested heart, which led him to conclude that the mechanical stimulation provided by the needle was probably the cause of heart cell depolarization[2]. He called the apparatus Artificial Pacemaker. Other workers reported effective pacing of the sino-atrial node of the dog by means of intravenous bipolar electrodes[3]. An internally powered pacemaker unit charged from outside the body was achieved in the late 1950's[4]. Then a complete implanted system powered by a zinc mercury cell battery was introduced[5].. Later on the present widely-used method of endocardial pacing was introduced[6]


Subject(s)
Heart Block
SELECTION OF CITATIONS
SEARCH DETAIL