1.
Indian J Med Microbiol ; 2009 July-Sept; 27(3): 217-221
Article in English | IMSEAR | ID: sea-143571

ABSTRACT

Aim: To evaluate the performance of an automated BACTEC MGIT 960, a non-radioactive, non-invasive liquid culture system for cultivation of M. tuberculosis complex in terms of recovery rate and time. Materials and Methods: From March 2005 to December 2007, 14,597 specimens were processed using the MGIT 960 system and the results were compared with conventional L.J medium. We standardised r-nitro benzoic acid (PNBA) assay on MGIT 960 TB system for identification of M. tuberculosis complex and evaluated its usefulness by comparing the results with an in-house molecular assay and sequencing. Results and Discussion: Of the total 6143 (42%) isolates positive for M. tuberculosis complex, 6015 (41%) were positive by MGIT 960 TB system. In contrast, 3526 (24%) M. tuberculosis complex isolates grew on the conventional L.J medium. The mean turn around time for mycobacterial growth in smear-positive specimens was nine days for MGIT 960, and 38 days for L.J. medium whereas in smear negative specimens it was 16 days by MGIT vs. 48 days by L.J. Conclusion: MGIT 960 system with PNBA assay for identification of M. tuberculosis complex is a rapid and useful method in laboratories processing a large number of specimens.

2.
Indian J Med Microbiol ; 2007 Jan; 25(1): 32-6
Article in English | IMSEAR | ID: sea-53643

ABSTRACT

PURPOSE: To evaluate, the efficacy of BACTEC 460 TB system for the diagnosis of tuberculosis in a tertiary care hospital in Mumbai, India. METHODS: We compared 12,726 clinical specimens using BACTEC 460 TB system and conventional method for detection of Mycobacterium tuberculosis over a period of six years. Result: The overall recovery rate was 39% by BACTEC technique and 29% using Lowenstein-Jensen (LJ) medium. An average detection time for B actec0 460 TB system was found to be 13.3 days and 15.3 days as against 31.2 days and 35.3 days by LJ method for respiratory and nonrespiratory specimens respectively. The average reporting time for drug susceptibility results ranged from 6-10 days for the BACTEC 460 TB system. CONCLUSIONS: The BACTEC system is a good system for level II laboratories, especially in the diagnosis of extrapulmonary and smear negative tuberculosis.


Subject(s)
Antitubercular Agents/pharmacology , Bacteriological Techniques/instrumentation , Humans , India , Microbial Sensitivity Tests , Mycobacterium tuberculosis/drug effects , Reproducibility of Results , Tuberculosis/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL