Journal of Human, Environment and Health Promotion. 2017; 2 (2): 105-111
in English | IMEMR | ID: emr-195816

ABSTRACT

Background: Safe drinking water is one of the main factors in improving health status of the population. The aim of this study was assessment of the microbiological quality, determination of pH and residual chlorine in water coolers' drinking water in educational centers of Zanjan University of medical Sciences in 2015 and comparing the results with the Iranian national standards


Methods: In this cross-sectional study, water samples of all used water cooler apparatuses were sampled and transferred rapidly to the laboratory. pH and residual free chlorine were measured by pH meter and Chlorine Residual Testing kit, respectively. Total coliforms, Escherichia coli, Mold and yeasts count were enumerated according to the Iranian national standards No. 1011, 3759, 5271 and 10899-1, respectively. Data were analyzed through the statistical softwares


Results: The obtained results indicated that 44.44% of the samples were non-standard because of low residual chlorine. 44.44% and 27.8% of the taken water samples of water cooler dispensers were contaminated with mold or yeast and Escherichia coli, respectively


Conclusion: According to some microbial contamination in water samples of water cooler devices to ensure availability clean water to consumers [students and hospital's visitors] continuous monitoring, proper maintenance and regular inspection of the water cooler dispensers seems necessary