Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 95
Filter
1.
Ultrasonography ; : 136-146, 2023.
Article in English | WPRIM | ID: wpr-969249

ABSTRACT

Purpose@#The aim of this study was to validate the postnatal urinary tract dilation (UTD) classification system by correlating it with the need for surgical intervention. @*Methods@#Young infants who underwent ultrasound (US) examinations for prenatal hydronephrosis were retrospectively identified. The kidney units (KUs; right, left, or bilateral) were graded from UTD P0 (very low risk) to P3 (high risk) based on seven US criteria from the UTD system. Surgery-free survival curves were constructed using the Kaplan-Meier method. Univariable and multivariable Cox proportional-hazards regression analysis clustered by patients was performed. Interobserver agreement was analyzed using the weighted kappa coefficient. @*Results@#In total, 504 KUs from 336 patients (mean age, 18.3±15.9 days; range, 1 to 94 days; males, n=276) were included, with a median follow-up of 24.2 months. Fifty-eight KUs underwent surgical intervention. Significant differences were observed among the Kaplan-Meier curves stratified into UTD groups (P<0.001). The presence of anterior-posterior renal pelvic diameter ≥15 mm (hazard ratio [HR], 8.602; 95% confidence interval [CI], 1.558 to 43.065), peripheral calyceal dilation (HR, 8.190; 95% CI, 1.558 to 43.065), ureteral dilation (HR, 2.619; 95% CI, 1.274 to 5.380), parenchymal thickness abnormality (HR, 3.371; 95% CI, 1.574 to 7.223), bladder abnormality (HR, 12.209; 95% CI, 3.616 to 41.225) were significantly associated with the occurrence of surgery. The interobserver agreement was moderate to almost perfect agreement for US features (κ=0.564-0.898) and substantial for final UTD grades (κ=0.716). @*Conclusion@#The UTD classification system is reliable and appropriately stratifies the risk of surgical intervention.

2.
Korean Journal of Anesthesiology ; : 37-46, 2022.
Article in English | WPRIM | ID: wpr-926566

ABSTRACT

Background@#We compared upper- and lower-body forced-air blankets in terms of their ability to prevent perioperative hypothermia, defined as a reduction in body temperature to < 36.0°C, during the perioperative period in patients undergoing spine surgery in the prone position. @*Methods@#In total, 120 patients scheduled for elective spine surgery under general anesthesia were divided into an upper-warming group (n = 60) and a lower-warming group (n = 60). After inducing anesthesia and preparing the patient for surgery, including prone positioning, the upper and lower bodies of the patients in the upper- and lower-warming groups, respectively, were warmed using a forced-air warmer with specified upper and lower blankets. Body temperature was measured using a tympanic membrane thermometer during the pre- and post-operative periods and using a nasopharyngeal temperature probe during the intraoperative period. Patients were evaluated in terms of shivering, thermal comfort, and satisfaction in the post-anesthesia care unit (PACU). @*Results@#The incidence of intraoperative and postoperative hypothermia was lower in the upper-warming group than in the lower-warming group ([55.2% vs. 75.9%, P = 0.019] and [21.4% vs. 49.1%, P = 0.002]). Perioperative body temperature was higher in the upper-warming group (P < 0.001). However, intraoperative blood loss, postoperative thermal comfort scale and shivering scores, patient satisfaction, and PACU duration were similar in the two groups. @*Conclusions@#The upper-body blanket was more effective than the lower-body blanket for preventing perioperative hypothermia in patients who underwent spine surgery in the prone position.

3.
Annals of Laboratory Medicine ; : 268-276, 2021.
Article in English | WPRIM | ID: wpr-874190

ABSTRACT

Background@#Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is increasingly used for immunosuppressive drug tests. However, most LC-MS/MS tests are laboratory-developed and their agreement is unknown in different Korean laboratories.This interlaboratory comparison study evaluated test reproducibility and identified potential error sources. @*Methods@#Test samples containing three concentrations of tacrolimus, sirolimus, everolimus, cyclosporine, and mycophenolic acid were prepared by pooling surplus samples from patients undergoing routine therapeutic drug monitoring and tested in duplicate in the participating 10 clinical laboratories. Reconstitution and storage experiments were conducted for the commonly used commercial calibrator set. The robust estimators of reproducibility parameters were calculated. Spearman’s rank correlation coefficient (rho, ρ) was used to evaluate the correlation between drugs. Multiple linear regression was used to determine whether the experimental conditions alter the calibration curves. @*Results@#The reproducibility coefficient of variation exceeded 10% only for sirolimus concentrations 1 and 2 (10.8% and 12.5%, respectively) and everolimus concentrations 1 and 2 (12.3% and 11.4%, respectively). The percent difference values showed weak correlations between sirolimus and everolimus (ρ = 0.334, P = 0.175). The everolimus calibration curve slope was significantly altered after reconstitution following prolonged 5°C storage (P = 0.015 for 14 days; P = 0.025 for 28 days); the expected differences at 6 ng/mL were 0.598% for 14 days and 0.384% for 28 days. @*Conclusions@#LC-MS/MS test reproducibility for immunosuppressive drugs seems to be good in the Korean clinical laboratories. Continuous efforts are required to achieve test standardization and harmonization, especially for sirolimus and everolimus.

4.
Annals of Laboratory Medicine ; : 225-229, 2021.
Article in English | WPRIM | ID: wpr-874170

ABSTRACT

In response to the ongoing coronavirus disease 2019 (COVID-19) pandemic, an online laboratory surveillance system was established to monitor severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) real-time reverse transcription-PCR (rRT-PCR) testing capacities and results. SARS-CoV-2 rRT-PCR testing data were collected from 97 clinical laboratories, including 84 medical institutions and 13 independent clinical laboratories in Korea. We assessed the testing capacities to utilize SARS-CoV-2 rRT-PCR based on surveillance data obtained from February 7th to June 4th, 2020 and evaluated positive result characteristics according to the reagents used and sample types. A total of 1,890,319 SARS-CoV-2 rRT-PCR testing were performed, 2.3% of which were positive. Strong correlations were observed between the envelope (E ) gene and RNA-dependent RNA polymerase (RdRp )ucleocapsid (N ) genes threshold cycle (Ct) values for each reagent. No statistically significant differences in gene Ct values were observed between the paired upper and lower respiratory tract samples, except in the N gene for nasopharyngeal swab and sputum samples. Our study showed that clinical laboratories in Korea have rapidly expanded their testing capacities in response to the COVID-19 outbreak, with a peak daily capacity of 34,193 tests. Rapid expansion in testing capacity is a critical component of the national response to the ongoing pandemic.

5.
Annals of Laboratory Medicine ; : 155-170, 2021.
Article in English | WPRIM | ID: wpr-874160

ABSTRACT

Background@#Reference intervals defined for adults or children of other ethnicities cannot be applied in the evaluation of Korean pediatric patients. Pediatric reference intervals are difficult to establish because children are in their growing stage and their physiology changes continuously. We aimed to establish reference intervals for routine laboratory tests for Korean pediatric patients through retrospective multicenter data analysis. @*Methods@#Preoperative laboratory test results from 1,031 pediatric patients aged 0 month–18 years who underwent minor surgeries in four university hospitals were collected. Age- and sex-specific reference intervals for routine laboratory tests were defined based on the Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. @*Results@#The pediatric reference intervals determined in this study were different from existing adult reference intervals and pediatric reference intervals for other ethnicities. Most tests required age-specific partitioning, and some of those required sex-specific partitioning for at least one age-partitioned subgroup. Erythrocyte sedimentation rate, monocyte percentage, basophil percentage, activated partial thromboplastin time, glucose, cholesterol, albumin, bilirubin, chloride, and C-reactive protein did not show any difference between age- or sex-partitioned subgroups. @*Conclusions@#We determined Korean pediatric reference intervals for hematology, coagulation, and chemistry tests by indirect sampling based on medical record data from multiple institutions. These reference intervals would be valuable for clinical evaluations in the Korean pediatric population.

6.
International Neurourology Journal ; : 355-363, 2021.
Article in English | WPRIM | ID: wpr-914695

ABSTRACT

Purpose@#The aim of this study was to assess the performance of a mobile acoustic Uroflowmetry (UFM) application compared with standard UFM in the pediatric population. @*Methods@#A mobile acoustic UFM application represents a noninvasive method to estimate the urine flow rate by recording voiding sounds with a smartphone. Male pediatric patients who were undergoing UFM testing were prospectively recruited, and the voiding sounds were recorded and analyzed. The intraclass correlation coefficient (ICC) was used to compare the maximum flow rate (Qmax), average flow rate (Qavg), voiding time (VT), and voiding volume (VV) as estimated by acoustic UFM with those calculated by standard UFM. Differences in Qmax, Qavg, VT, and VV between the 2 UFM tests were determined using 95% Bland-Altman limits of agreement. @*Results@#A total of 16 male patients were evaluated. Their median age was 9 years. With standard UFM, the median Qmax, Qavg, VT, and VV were 18.7 mL/sec, 11.1 mL/sec, 15.2 seconds, and 157.8 mL, respectively. Strong correlations were observed between the 2 methods for Qmax (ICC=0.755, P=0.005), VT (ICC=0.974, P<0.001), and VV (ICC=0.930, P<0.001), but not for Qavg (ICC=0.442, P=0.135). The Bland-Altman plot showed good agreement between the 2 UFM tests. Flow patterns recorded by acoustic UFM and conventional UFM showed good visual correlations. @*Conclusions@#Acoustic UFM was comparable to standard UFM for male pediatric patients. Further validation of its performance in different toilet settings is necessary for broader use.

7.
The Korean Journal of Internal Medicine ; : 782-787, 2020.
Article | WPRIM | ID: wpr-831790

ABSTRACT

Background/Aims@#As the coronavirus disease-2019 global pandemic progresses, screening of antiviral agents effective against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is urgently needed. In addition, considering the viral load kinetics of SARS-CoV-2, which peaks early in the illness, and the massive burden of the disease, which may increase in the near future, identifying well-tolerated oral antivirals becomes increasingly important. We examined the in vitro activity of lopinavir/ritonavir and hydroxychloroquine on SARS-CoV-2, at concentrations which can be used to treat coronavirus-19 patients with little concern of toxicity. @*Methods@#Lopinavir/ritonavir (7/1.75 μg/mL), hydroxychloroquine base (1 or 2 μg/mL), or a combination thereof were administered 1 hour after the inoculation of SARS-CoV-2 to Vero cells at a multiplicity of infection of 0.05. We examined cytopathic effects of virus 48 hours after administration of the respective treatments and measured viral loads at three time points (0, 24, and 48 hours post-treatment) by quantitative real-time reverse-transcription polymerase chain reaction, and compared the results obtained from the different antiviral regimens tested. @*Results@#The severity of cytopathic effects was lower in lopinavir/ritonavir-treated cells, and viral load was significantly reduced in this group compared with the control group (p < 0.001). However, hydroxychloroquine did not show significant inhibitory effects on anti-SARS-CoV-2-mediated cytotoxicity or on viral load at either concentration. @*Conclusions@#Lopinavir/ritonavir showed significant inhibitory effects on SARS-CoV-2 in vitro at its usual plasma concentration. However, the in vitro antiviral activity of hydroxychloroquine at concentrations commonly used in humans was minimal, whether used alone or in combination with lopinavir/ritonavir.

8.
Journal of Korean Medical Science ; : e231-2020.
Article | WPRIM | ID: wpr-831636

ABSTRACT

There have been controversies on the prophylactic effect of hydroxychloroquine against severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). We describe a patient, 60-year old Korean woman, with coronavirus disease 2019 (COVID-19) who had been taking hydroxychloroquine for 6 months. Her serum and saliva concentrations of hydroxychloroquine were 280 μg/L and 4,890 μg/L, respectively. The present case raises concerns on hydroxychloroquine's role as a prophylactic agent for COVID-19.

9.
Clinical and Experimental Emergency Medicine ; (4): 35-42, 2020.
Article | WPRIM | ID: wpr-831259

ABSTRACT

Objective@#We aimed to compare the multi-marker strategy (copeptin and high-sensitivity cardiac troponin I [hs-cTnI]) with serial hs-cTnI measurements to rule out acute myocardial infarction (AMI) in patients with chest pain. @*Methods@#This prospective observational study was performed in a single emergency department. To test the non-inferiority margin of 4% in terms of negative predictive value (NPV) between the multi-marker strategy (0 hour) and serial hs-cTnI measurements (0 and 2 hours), 262 participants were required. Samples for copeptin and hs-cTnI assays were collected at presentation (0 hour) and after 2 hours. The measured biomarkers were considered abnormal when hs-cTnI was >26.2 ng/L and when copeptin was >10 pmol/L. @*Results@#AMI was diagnosed in 28 patients (10.7%). The NPV of the multi-marker strategy was 100% (160/160; 95% confidence interval [CI], 97.7% to 100%), which was not inferior to that of serial hs-cTnI measurements (201/201; 100%; 95% CI, 98.2% to 100%). The sensitivity, specificity, and positive predictive value of the multi-marker strategy were 100% (95% CI, 87.7% to 100%), 68.1% (95% CI, 61.7% to 74.0%), and 27.2% (95% CI, 18.9% to 36.8%), respectively. The sensitivity, specificity, and positive predictive value of serial hs-cTnI measurements were 100% (95% CI, 87.7% to 100%), 85.5% (95% CI, 80.4% to 89.8%), and 45.2% (95% CI, 32.5% to 58.3%), respectively. @*Conclusion@#The multi-marker strategy (copeptin and hs-cTnI measurement) was not inferior to serial hs-cTnI measurements in terms of NPV for AMI diagnosis, with a sensitivity and NPV of 100%. Copeptin may help in the early rule-out of AMI in patients with chest pain.

10.
Ultrasonography ; : 152-158, 2020.
Article | WPRIM | ID: wpr-835308

ABSTRACT

Purpose@#We aimed to document the time of onset of ultrasonographic and histologic changes in the testes of a rat model following testicular torsion. @*Methods@#Twenty-five Sprague-Dawley rats were divided into four groups. All animals underwent preoperative Doppler ultrasonography. Groups 1, 2, and 3 underwent unilateral surgical torsion of the testis lasting for 72, 24, and 6 hours, respectively. Group 4 underwent a sham operation. The animals were followed with Doppler ultrasonography at 6, 24, 48, and 72 hours postoperatively. Histologic examinations were performed at the designated final time point for each group. @*Results@#After torsion, enlargement of the epididymal head and thickening of the spermatic cord over time were noted. Based on the ultrasonographic dimensions, the ratio of the epididymal volume increased with time following torsion (p=0.002). The torsed testes had an average weight gain of 0.27 g at 6 hours compared to the control testes, but an average weight loss of 0.22 g at 72 hours (P=0.006). Changes in testicular echotexture were noted as soon as 6 hours after torsion, but there was no consistent pattern of echotexture change thereafter. Histologically, viable tubules were seen 6 hours after torsion, while extensive hemorrhagic necrosis was found at 72 hours. @*Conclusion@#In evaluating testicular torsion, the enlargement ratio of the epididymis and thickening of the spermatic cord on Doppler ultrasonography may be useful for determining the urgency of immediate surgery. Changes in testicular echotexture may not be a reliable indicator of the time of onset.

12.
Laboratory Medicine Online ; : 185-196, 2020.
Article | WPRIM | ID: wpr-836926

ABSTRACT

The use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) in clinical laboratories is increasing and is likely to expand into even more clinical venues in the future. Mass spectrometry is the standard method for analyte identification in the clinical chemistry field; however, differences in mass spectrometry protocols and handling affect the accuracy and reliability of these tests and prevent direct comparisons of results between laboratories. For example, the results of laboratories using LC-MS/MS methods are less likely to be reproducible than those of laboratories using conventional, automated methods. This is due to inadequate handling of the equipment and/or poor quality control after the implementation of the method, which may result in unnecessary medical expenditures or even adverse outcomes for the patients. Unfortunately, guidelines to monitor the accuracy of LC-MS/MS-based clinical tests are still lacking. In general, the quality control methods used in conventional clinical tests could also be applied to LC-MS/MS. However, additional quality control methods specific to LC-MS/MS techniques must be continuously employed to maintain the same quality level achieved during method development and verification. This report is intended to help clinical laboratories that operate LC-MS/MS improve the accuracy and reliability of their testing by providing guidance for quality assurance and improvement, based on a collection of existing guidelines and expert opinions from the literature.

13.
Laboratory Medicine Online ; : 242-246, 2020.
Article | WPRIM | ID: wpr-836918

ABSTRACT

Cross-reactive carbohydrate determinants (CCDs) are simple carbohydrates linked to amino acid chains; they are found in pollens, vegetable foods, insect, and Hymenoptera venoms and are broadly cross-reactive with CCD-specific IgE antibodies. A man in his fifties was evaluated using a multiple allergen simultaneous test–immunoblot assay. On the PROTIA Allergy-Q 64 inhalant panel (ProteomeTech, Korea), reactions to 37 of 59 antigens were observed except mammalian antigens, and cross-reactivity owing to anti-CCD antibodies was suspected. After ProGlycAn CCD-blocker (ProGlycAn, Austria) treatment, the patient exhibited no response to CCD allergens, and the number of allergens showing positive reactions was reduced to 15. We further tested a total of 7 samples from patients who were suspected to have CCD-related cross-reactivity. For these 8 patients, the average number of positive reactions to allergens was reduced from 33 (range 24-36) to 8 (range 0-19) after CCD-blocker treatment. We concluded that CCD-blocker treatment in sample with anti-CCD antibodies can reduce the false positive reponse and provide more specific information about allergens.

14.
Blood Research ; : 17-22, 2019.
Article in English | WPRIM | ID: wpr-739439

ABSTRACT

Genetic hemoglobin disorders are caused by mutations and/or deletions in the α-globin or β-globin genes. Thalassemia is caused by quantitative defects and hemoglobinopathies by structural defect of hemoglobin. The incidence of thalassemia and hemoglobinopathy is increased in Korea with rapid influx of people from endemic areas. Thus, the awareness of the disease is needed. α-thalassemias are caused by deletions in α-globin gene, while β-thalassemias are associated with decreased synthesis of β-globin due to β-globin gene mutations. Hemoglobinopathies involve structural defects in hemoglobin due to altered amino acid sequence in the α- or β-globin chains. When the patient is suspected with thalassemia/hemoglobinopathy from abnormal complete blood count findings and/or family history, the next step is detecting hemoglobin abnormality using electrophoresis methods including high performance liquid chromatography and mass spectrometry. The development of novel molecular genetic technologies, such as massively parallel sequencing, facilitates a more precise molecular diagnosis of thalassemia/hemoglobinopathy. Moreover, prenatal diagnosis using genetic testing enables the prevention of thalassemia birth and pregnancy complications. We aimed to review the spectrum and classification of thalassemia/hemoglobinopathy diseases and the diagnostic strategies including screening tests, molecular genetic tests, and prenatal diagnosis.


Subject(s)
Humans , Amino Acid Sequence , Anemia , Blood Cell Count , Chromatography, Liquid , Classification , Clinical Laboratory Techniques , Diagnosis , Electrophoresis , Erythrocytes , Genetic Testing , Hematology , Hemoglobinopathies , High-Throughput Nucleotide Sequencing , Incidence , Korea , Mass Screening , Mass Spectrometry , Molecular Biology , Parturition , Pregnancy Complications , Prenatal Diagnosis , Thalassemia
16.
Laboratory Medicine Online ; : 161-165, 2019.
Article in Korean | WPRIM | ID: wpr-760500

ABSTRACT

The Clinical Mass Spectrometry Research Committee (CMSRC), in affiliation with the Korean Society of Clinical Chemistry (KSCC), conducted a questionnaire survey on opinions about the general status of clinical mass spectrometric analysis in Korea. As a result, we understand that this field has passed through the introductory stage and is settled as a field of clinical laboratory testing in Korea, with the number of new laboratories performing mass spectrometric analysis being low. In spite of the many difficulties in introducing and operating clinical mass spectrometric analysis, there is a strong interest in this field, and even though further expansion is expected, there are still many issues to be resolved. In the future, it will be necessary to make concrete and thorough efforts to further develop the laboratory tests using clinical mass spectrometric analysis in Korea, centering on the CMSRC affiliated with the KSCC.


Subject(s)
Chemistry, Clinical , Korea , Mass Spectrometry
17.
Annals of Laboratory Medicine ; : 552-560, 2019.
Article in English | WPRIM | ID: wpr-762439

ABSTRACT

BACKGROUND: In Korea, the Korean Laboratory Accreditation Program (KLAP) has set minimum standards for verification of clinical test performance. This verification process is time-consuming and labor-intensive when performed manually. We developed a free, statistical software program for KLAP, using the R language (R Foundation for Statistical Computing, Vienna, Austria). METHODS: We used CLSI guidelines for the algorithm. We built graphic user interfaces, including data input, with Embarcadero Delphi EX4 (Embarcadero Technologies, Inc., Texas, USA). The R Base Package and MCR Package for Method Comparison Regression were used to implement statistical and graphical procedures. RESULTS: Our program LaboStats has six modules: parallel test, linearity, method comparison, precision, reference interval, and cutoff. Data can be entered into the field either manually or by copying and pasting from an MS Excel worksheet. Users can print out precise reports. CONCLUSIONS: LaboStats can be useful for evaluating clinical test performance characteristics and preparing documents requested by KLAP.


Subject(s)
Accreditation , Korea , Mathematical Computing , Methods , Texas
18.
Asian Journal of Andrology ; (6): 69-74, 2018.
Article in English | WPRIM | ID: wpr-1009528

ABSTRACT

This study aimed to investigate perceived ejaculatory function/satisfaction before treatment for lower urinary tract symptoms (LUTS)/benign prostatic hyperplasia (BPH) and to identify associations between specific categories of ejaculatory dysfunctions (EjDs) and LUTS. A total of 1574 treatment-naïve men with LUTS/BPH were included in this study. All patients underwent routine evaluation for LUTS/BPH including the International Index of Erectile Function and a 5-item questionnaire developed to assess ejaculatory volume/force/pain/satisfaction/latency time. Patients who had sexual intercourse over the past 4 weeks were classified as sexually active group. A total of 783 patients were categorized as sexually active group. Decreased ejaculatory volume and force were reported by 53.4% and 55.7% of 783 sexually active men, respectively. There was a strong correlation between ejaculatory volume and force. Ejaculatory pain/discomfort, premature ejaculation (PE), and delayed ejaculation (DE) were reported in 41.0%, 16.3%, and 41.4% of the patients, respectively. Over 40.0% of men without decreased ejaculation volume/force were satisfied with ejaculatory function, whereas approximately 6.0% of men with decreased volume/force were satisfied with ejaculatory function. About 30.0% of men with decreased volume/force had orgasmic dysfunction, while approximately 10.0% of men without decreased volume/force did. Decreased ejaculatory volume or force was associated with LUTS severity after adjusting for other influential factors including testosterone level, erectile function, and prostate size on ultrasonography, but PE or DE or ejaculatory pain/discomfort was not. In conclusion, a considerable portion of men with LUTS/BPH appear to have a variety of EjDs. Ejaculatory volume/force and satisfaction/orgasm do not always appear to be concordant. Ejaculatory volume or force is independently associated with LUTS severity, whereas PE or DE or ejaculatory pain/discomfort is not.


Subject(s)
Aged , Humans , Male , Middle Aged , Coitus , Ejaculation , Lower Urinary Tract Symptoms/physiopathology , Orgasm , Pain/etiology , Personal Satisfaction , Premature Ejaculation/physiopathology , Prostate/diagnostic imaging , Prostatic Hyperplasia/physiopathology , Sexual Dysfunction, Physiological/physiopathology , Surveys and Questionnaires , Testosterone/blood
19.
Annals of Laboratory Medicine ; : 85-94, 2018.
Article in English | WPRIM | ID: wpr-713440

ABSTRACT

BACKGROUND: The immunosuppressant drugs (ISDs), tacrolimus and cyclosporine, are vital for solid organ transplant patients to prevent rejection. However, toxicity is a concern, and absorption is highly variable across patients; therefore, ISD levels need to be precisely monitored. In the Asia-Pacific (APAC) region, tacrolimus and cyclosporine concentrations are typically measured using immunoassays. The objective of this study was to assess the analytical performance of Roche Elecsystacrolimus and cyclosporinee electrochemiluminescence immunoassays (ECLIAs). METHODS: This evaluation was performed in seven centers across China, South Korea, and Malaysia. Imprecision (repeatability and reproducibility), assay accuracy, and lot-to-lot reagent variability were tested. The Elecsys ECLIAs were compared with commercially available immunoassays (Architect, Dimension, and Viva-E systems) using whole blood samples from patients with various transplant types (kidney, liver, heart, and bone marrow). RESULTS: Coefficients of variation for repeatability and reproducibility were ≤5.4% and ≤12.4%, respectively, for the tacrolimus ECLIA, and ≤5.1% and ≤7.3%, respectively, for the cyclosporine ECLIA. Method comparisons of the tacrolimus ECLIA with Architect, Dimension, and Viva-E systems yielded slope values of 1.01, 1.14, and 0.897, respectively. The cyclosporine ECLIA showed even closer agreements with the Architect, Dimension, and Viva-E systems (slope values of 1.04, 1.04, and 1.09, respectively). No major differences were observed among the different transplant types. CONCLUSIONS: The tacrolimus and cyclosporine ECLIAs demonstrated excellent precision and close agreement with other immunoassays tested. These results show that both assays are suitable for ISD monitoring in an APAC population across a range of different transplant types.


Subject(s)
Humans , Absorption , China , Cyclosporine , Drug Monitoring , Heart , Immunoassay , Korea , Liver , Malaysia , Methods , Tacrolimus , Transplants
20.
Annals of Clinical Microbiology ; : 12-19, 2018.
Article in English | WPRIM | ID: wpr-713358

ABSTRACT

BACKGROUND: Timely intervention in the treatment of bloodstream infection is important for prescription of appropriate antimicrobials. With prompt determination of the antimicrobial susceptibility of a causative agent, rapid antimicrobial susceptibility test (AST) can help select the appropriate antimicrobial therapy. This clinical study is for evaluation of the clinical performance of the QMAC-dRAST for rapid AST directly from positive blood culture (PBC)s with Gram-positive cocci. METHODS: A total of 115 PBC samples with Gram-positive organisms (76 Staphylococcus spp. and 39 Enterococcus spp.) were evaluated by the QMAC-dRAST system, and their pure culture isolates were evaluated by the MicroScan WalkAway (Beckman Coulter, USA) as the comparative AST system. Thirteen antimicrobial agents were included, and the agreement and discrepancy rates of the QMAC-dRAST system (Quantamatrix Inc., Republic of Korea) compared to the MicroScan WalkAway were calculated. To resolve discrepancies, the broth microdilution method was performed. RESULTS: The QMAC-dRAST system exhibited a categorical agreement rate of 94.9% (1,126/1,187) and an essential agreement rate of 98.3% (1,167/1,187). The QMAC-dRAST system yielded very major (false-susceptible) errors at 1.0% (5/485), major (false-resistant) errors at 1.3% (9/693), and minor errors at 4.0% (47/1,187) compared to the MicroScan WalkAway. The QMAC-dRAST system significantly eliminated 30 hours of total turnaround time by combination of direct inoculation of PBC and an image-based approach. CONCLUSION: The results of the QMAC-dRAST system were highly accurate. Thereby, the QMAC-dRAST may provide essential information to accelerate therapeutic decisions for earlier and adequate antibiotic treatment and patient management in clinical settings.


Subject(s)
Humans , Anti-Infective Agents , Bacteremia , Bioengineering , Clinical Study , Drug Resistance, Microbial , Enterococcus , Gram-Positive Cocci , Methods , Microbial Sensitivity Tests , Prescriptions , Staphylococcus
SELECTION OF CITATIONS
SEARCH DETAIL