1.
Radiol. bras ; 47(1): 28-32, Jan-Feb/2014. graf
Article in English | LILACS | ID: lil-703655

ABSTRACT

Objective The present study evaluated the reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications. Materials and Methods Thirty-five patients under high-risk for development of carotid artery calcifications who had digital panoramic radiography were referred to undergo ultrasonography. Thus, 70 arteries were assessed by both methods. The main parameters utilized to evaluate the panoramic radiography reliability in the diagnosis of carotid artery calcifications were accuracy, sensitivity, specificity and positive predictive value of this method as compared with ultrasonography. Additionally, the McNemar's test was utilized to verify whether there was a statistically significant difference between digital panoramic radiography and ultrasonography. Results Ultrasonography demonstrated carotid artery calcifications in 17 (48.57%) patients. Such individuals presented with a total of 29 (41.43%) carotid arteries affected by calcification. Radiography was accurate in 71.43% (n = 50) of cases evaluated. The degree of sensitivity of this method was 37.93%, specificity of 95.12% and positive predictive value of 84.61%. A statistically significant difference (p < 0.001) was observed between the methods evaluated in their capacity to diagnose carotid artery calcifications. Conclusion Digital panoramic radiography should not be indicated as a method of choice in the investigation of carotid artery calcifications. .


Objetivo O presente estudo avaliou a confiabilidade da radiografia panorâmica digital no diagnóstico de calcificações na artéria carótida. Materiais e Métodos Trinta e cinco pacientes de alto risco para o desenvolvimento de calcificações na artéria carótida que tinham a radiografia panorâmica digital foram encaminhados para realização do exame de ultrassonografia. Assim, 70 artérias foram avaliadas pelos dois exames. Os principais parâmetros utilizados para avaliar a confiabilidade da radiografia panorâmica no diagnóstico de calcificações na artéria carótida foram a precisão, a sensibilidade, a especificidade e o valor preditivo positivo desse método quando comparado à ultrassonografia. Além disso, o teste de McNemar foi utilizado para verificar se existia diferença estatisticamente significante entre a radiografia panorâmica digital e ultrassonografia. Resultados De acordo com a ultrassonografia, 17 (48,57%) pacientes apresentavam calcificações na artéria carótida. Esses indivíduos apresentavam um total de 29 (41,43%) artérias carótidas atingidas por calcificações. O exame radiográfico foi preciso em acertar 71,43% (n = 50) dos casos avaliados. O grau de sensibilidade desse método foi 37,93%, especificidade de 95,12% e valor preditivo positivo de 84,61%. Além disso, foi verificada diferença estatisticamente significante (p < 0,001) entre os exames avaliados na capacidade de diagnosticar calcificações na artéria carótida. Conclusão A radiografia panorâmica digital não deve ser indicada como exame de excelência para investigação da presença de calcificações na artéria carótida. .

2.
São Paulo med. j ; 132(2): 97-104, 2014. tab, graf
Article in English | LILACS | ID: lil-705381

ABSTRACT

CONTEXT AND OBJECTIVE: The thickness of the carotid intima-media complex (C-IMC) is considered to be a marker of early atherosclerosis, but visual and echogenic changes to the C-IMC can also be noted. The objective here was to evaluate the relationship between cardiovascular risk factors and the echogenicity of the C-IMC and identify those most associated with an "abnormal" C-IMC. DESIGN AND SETTING: Cross-sectional study in the ultrasound sector of the Department of Diagnostic Imaging, Universidade Federal de São Paulo. METHODS: Eighty men were evaluated. Measurements of arterial blood pressure, waist circumference (WC), lipid profile, fasting glucose, uric acid and high-sensitivity C-reactive protein were obtained. The thickness of the C-IMC was measured by means of B-mode ultrasound, and the intima-media gray-scale mean (IM-GSM) and standard deviation (IM-SD) were calculated. RESULTS: The following were discriminating variables: fasting glucose (r2 = 0.036; P = 0.013), uric acid (r2 = 0.08; P = 0.03), IM-SD (r2 = 0.43; P < 0.001), IM-GSM (r2 = 0.35; P < 0.001) and thickness of the C-IMC (r2 = 0.29; P < 0.001). IM-GSM showed significant correlations with WC (r = -0.22; P = 0.005), fasting glucose (r = -0.24; P = 0.002) and high-density lipoprotein cholesterol (HDL-C) (r = 0.27; P = 0.0007). CONCLUSION: IM-GSM showed correlations with WC, fasting glucose and HDL-C. However, uric acid and IM-SD presented the greatest discriminating impact. These results suggest that visual changes in C-IMC may help identify patients with potential cardiovascular risk, independently of the thickness of the C-IMC. .


CONTEXTO E OBJETIVO: A espessura do complexo íntima-média carotídeo (CIM-C) é considerada um marcador da aterosclerose precoce, mas alterações visuais e da ecogenicidade do CIM-C também podem ser observadas. O objetivo foi avaliar a relação entre os fatores de risco cardiovascular e a ecogenicidade do CIM-C e identificar aqueles mais relacionados com o CIM-C "alterado". TIPO DE ESTUDO E LOCAL: Estudo transversal no setor de ultrassonografia do Departamento de Diagnóstico por Imagem, Universidade Federal de São Paulo. MÉTODOS: Oitenta homens foram avaliados. Aferição da pressão arterial, medida da circunferência abdominal (CA), perfil lipídico, glicemia de jejum (GLI), ácido úrico (AU) e proteína C-reativa de alta sensibilidade foram obtidos. A espessura do CIM-C foi medida por ultrassom modo B e a média da escala de cinza (GSM) e do desvio padrão do CIM (DPIM) foram calculados. RESULTADOS: As variáveis discriminantes foram GLI (r2 = 0,036; P = 0,013), AU (r2 = 0,08; P = 0,03), DPIM (r2 = 0,43; P < 0,001), GSM (r2 = 0,35; P < 0,001) e espessura do CIM-C (r2 = 0.29; P < 0,001). Houve correlação significativa entre GSM e CA (r = -0,22; P = 0,005), GLI (r = -0,24; P = 0,002) e lipoproteína de alta densidade do colesterol (HDL-C) (r = 0,27; P = 0,0007). CONCLUSÃO: A GSM teve correlação com CA, GLI, HDL-C. Entretanto, AU e DPIM apresentaram maior impacto discriminante, sugerindo que alterações visuais do CIM-C, independentemente da espessura, podem auxiliar na identificação de pacientes com potencial risco cardiovascular. .


Subject(s)
Adult , Humans , Male , Middle Aged , Cardiovascular Diseases , Carotid Artery, Common , Carotid Intima-Media Thickness , Metabolic Syndrome , Atherosclerosis/physiopathology , Atherosclerosis , C-Reactive Protein/analysis , Cardiovascular Diseases/etiology , Cardiovascular Diseases/physiopathology , Carotid Artery, Common/physiopathology , Cross-Sectional Studies , Fasting/blood , Glucose/metabolism , Lipoproteins, HDL/blood , Metabolic Syndrome/physiopathology , Reference Values , Risk Assessment , Risk Factors , Uric Acid/blood , Waist Circumference