Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
RSBO (Impr.) ; 4(1): 37-45, maio 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-873541

ABSTRACT

Os objetivos deste estudo foram avaliar a resistência de união de dois sistemas adesivos autocondicionantes em dentina bovina e discutir alguns conceitos que envolvem os adesivos contemporâneos e os ensaios de resistência de união. Incisivos bovinos foram preparados com auxílio de lixas de carbeto de silício até a obtenção de superfícies planas de dentina média (60 mm2). Os adesivos Clearfil SE Bond (Kuraray) e Clearfil S3 Bond (Kuraray) foram aplicados, e matrizes Tygon foram posicionadas sobre cada amostra de dentina hibridizada, sendo preenchidas em seu volume interno com o cimento resinoso RelyX ARC (3M Espe). Após fotoativação, removeram-se as matrizes e expurseram-se os corpos-de-prova, que foram armazenados em água destilada 37ºC por 24 horas. Decorrido esse período, os corpos-de-prova foram unidos ao dispositivo de teste e ensaiados em uma máquina universal de ensaios (EMIC DL 500), com velocidade de 0,5 mm/min. A resistência a de união foi calculada em Mpa, e os dados foram analisados estatisticamente pelo teste "t" de Student. Os resultados (MPa±DP) indicaram que a aplicação do adesivo Clearfil SE Bond resultou em maior média de resistência de união (26,74±7,53a), com diferença estatística em relação ao adesivo Clearfil S3 Bond (20,94±5,48b). De acordo com a revisão de literatura, a união à dentina parece ser instável para os sistemas adesivos simplificados (aqueles que contêm os componentes hidrófilos e hidrófobos em um só frasco)


The objective of this study was to evaluate the microshear bond strength of two self-etching adhesive systems on bovine dentin, and discuss some concepts involving contemporary adhesives, and shear bond strength tests. Bovine incisors were prepared using silicon carbide papers to obtain flat surfaces of middle dentin (60mm2). The adhesives Clearfil SE Bond/Kuraray and Clearfil S3 Bond/Kuraray were applied, and Tygon tubing positioned over each sample of hybridized dentin. The interior space was filled in with RelyX ARC (3M Espe) resin cement. After photoactivation, the tubes were removed and samples were exposed, which were stored in distilled water at 37ºC for 24 hours. After this period, the samples were bonded to the test device, and tested in a universal testing machine (EMIC DL 500) with a speed of 0.5mm/min. The bond strength was calculated in MPa and the data were analyzed statistically by the Student "t" test. The results (MPa±DP) indicate that the application of the adhesive Clearfil SE Bond resulted in higher bond strength (26.74±7,53a), with a statistical difference in relation to the adhesive Clearfil S3 Bond (20.94±5,48b). According to the literature review, the dentin bond appears to be unstable for simplified adhesive systems (those which contain hydrophilic and hydrophobic components in the same bottle)


Subject(s)
Animals , Cattle , Incisor , Dentin-Bonding Agents , Dentin , Shear Strength
2.
Rev. bras. odontol ; 54(4): 225-7, jul.-ago. 1997.
Article in Portuguese | LILACS, BBO | ID: lil-210984

ABSTRACT

A técnica de esplintagem utilizada constitui um dos fatores que influenciam na cicatrizaçäo periodontal após a luxaçäo ou avulsäo dentária. Visto que há uma grande variedade de técnicas de contençäo, torna-se necessária uma avaliaçäo destas em relaçäo ao propósito a que se destinam. Atualmente acredita-se que os movimentos fisiológicos favorecem à cicatrizaçäo funcional do ligamento periodontal. E por esta razäo que se preconiza a utilizaçäo de um esplinte funcional já que, ao mesmo tempo em que promove a estabilizaçäo do dente, permite a açäo destes movimentos. Este trabalho tem por objetivo revisar os princípios de esplintagem de dentes traumatizados e apresentar uma análise de alguns tipos de ferulizaçäo


Subject(s)
Humans , Tooth Avulsion/therapy , Tooth Injuries/therapy , Wound Healing , Composite Resins , Orthodontic Retainers , Orthodontic Wires , Periodontal Ligament , Tooth Replantation
SELECTION OF CITATIONS
SEARCH DETAIL