Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Braz. j. pharm. sci ; 51(1): 203-211, Jan-Mar/2015. tab, graf
Article in English | LILACS | ID: lil-751358

ABSTRACT

Average bioequivalence of two 500 mg levofloxacin formulations available in Brazil, Tavanic(c) (Sanofi-Aventis Farmacêutica Ltda, Brazil, reference product) and Levaquin(c) (Janssen-Cilag Farmacêutica Ltda, Brazil, test product) was evaluated by means of a randomized, open-label, 2-way crossover study performed in 26 healthy Brazilian volunteers under fasting conditions. A single dose of 500 mg levofloxacin tablets was orally administered, and blood samples were collected over a period of 48 hours. Levofloxacin plasmatic concentrations were determined using a validated HPLC method. Pharmacokinetic parameters Cmax, Tmax, Kel, T1/2el, AUC0-t and AUC0-inf were calculated using noncompartmental analysis. Bioequivalence was determined by calculating 90% confidence intervals (90% CI) for the ratio of Cmax, AUC0-t and AUC0-inf values for test and reference products, using logarithmic transformed data. Tolerability was assessed by monitoring vital signs and laboratory analysis results, by subject interviews and by spontaneous report of adverse events. 90% CIs for Cmax, AUC0-t and AUC0-inf were 92.1% - 108.2%, 90.7% - 98.0%, and 94.8% - 100.0%, respectively. Observed adverse events were nausea and headache. It was concluded that Tavanic(c) and Levaquin(c) are bioequivalent, since 90% CIs are within the 80% - 125% interval proposed by regulatory agencies.


A bioequivalência média de duas formulações de levofloxacino disponíveis no Brasil, Tavanic(c) (Sanofi-Aventis Farmacêutica Ltda, Brasil, produto referência) e Levaquin(c) (Janssen-Cilag Farmacêutica Ltda, Brasil, produto teste) foi determinada por meio da realização de ensaio aleatório, aberto, cruzado, com dois períodos e duas sequências, em 26 voluntários sadios em condições de jejum. Amostras de sangue dos voluntários foram obtidas ao longo de um período de 48 horas após administração de dose única de 500 mg de levofloxacino. As concentrações plasmáticas do fármaco foram determinadas por método cromatográfico validado. Os parâmetros farmacocinéticos Cmax, Tmax, Kel, T1/2el, AUC0-t e AUC0-inf foram calculados por análise não compartimental. A bioequivalência foi determinada pelo cálculo de intervalos de confiança 90% (IC 90%) para as razões entre os valores de Cmax, AUC0-t e AUC0-inf obtidos para os produtos teste e referência, usando dados transformados logaritmicamente. A tolerabilidade foi avaliada pelo acompanhamento dos sinais vitais e resultados de exames laboratoriais, por consultas e por relato espontâneo dos voluntários. ICs 90% para Cmax, AUC0-t e AUC0-inf foram 92.1% - 108.2%, 90.7% - 98.0%, e 94.8% - 100.0%, respectivamente. Os eventos adversos observados foram náusea e cefaleia. Concluiu-se que os produtos Tavanic(c) e Levaquin(c) são bioequivalentes, uma vez que os ICs 90% estão dentro da faixa de 80%-125% proposta pelas agências reguladoras.


Subject(s)
Humans , Volunteers/classification , Therapeutic Equivalency , Random Allocation , Single Dose/drug effects , Levofloxacin/analysis , Pharmacokinetics , Chromatography, Liquid/methods
2.
São Paulo; s.n; 16 dez. 2008. 216 p. tab, graf.
Thesis in Portuguese | LILACS | ID: lil-508065

ABSTRACT

No Brasil, os medicamentos genéricos e similares devem ser submetidos a ensaios de biodisponibilidade relativa/ bioequivalência para comprovação de sua intercambiabilidade com o medicamento referência. Nestes ensaios, o medicamento genérico, ou similar, é comparado com o medicamento referência em um estudo cruzado, mas não é comparado com outros genéricos ou similares do mercado. Desta forma, podemos afirmar que todo medicamento genérico ou similar é intercambiável com o medicamento de referência, mas não temos informações sobre a intercambiabilidade de um genérico com outro genérico ou com um similar. Entretanto, é comum que os pacientes substituam não apenas medicamento de referência pelo genérico ou similar correspondente, mas também um genérico por outro genérico, ou um genérico por um similar. Assim sendo, a questão que se coloca é se essas substituições entre genéricos e entre genérico e similar, podem gerar problemas de eficácia e/ou segurança para os pacientes. Para tentar responder essa questão foi proposta uma análise estatística, a meta-análise, onde seria possível avaliar a biodisponibilidade relativa/ bioequivalência entre genéricos, entre similares ou genérico e similar a partir dos resultados dos ensaios em que estes medicamentos foram comparados ao referência. Assim, o objetivo do estudo proposto foi aplicar técnicas estatísticas de meta-análise na avaliação da intercambiabilidade entre diferentes medicamentos similares de um mesmo medicamento referência. Amoxicilina foi escolhida como fármaco modelo para este estudo. Foram realizados três estudos de bioidisponibilidade relativa do tipo quantitativo direto, com delineamento aleatório, cruzado e aberto para comparar os produtos (Ti, T2, T3) a três diferentes lotes do produto de referência (R1, R2, R3)...


Subject(s)
Humans , Male , Female , Amoxicillin/administration & dosage , Amoxicillin/adverse effects , Amoxicillin/pharmacokinetics , Drugs, Generic , Interchange of Drugs , Reference Drugs , Similar Drugs , Biological Availability , Reference Standards , Plasma , Data Interpretation, Statistical , Therapeutic Equivalency
SELECTION OF CITATIONS
SEARCH DETAIL