Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of the Korean Radiological Society ; : 109-114, 1995.
Article in Korean | WPRIM | ID: wpr-140894

ABSTRACT

PURPOSE: Percutaneous needle aspiration biopsy under the imaging guidance in the diagnosis of intrathoracic diseases has become a standard practice. Core tissue obtained by automated gun biopsy(AGB) is believed to be more diagnostic than materials from fine needle aspiration(FNA) by many cytopathologists. The authors evauated the role of automated gun biopsy in localized pulmonary lesions with respect to the its accuracy and complications. MATERIALS AND METHODS: We performed 107 percutaneous biopsies in localized pulmonary lesions under fluoroscopic guidance among 107 patients:AGB using 18G or 20G was done in 81 patients, and both AGB and FNA was done in 26 patients. RESULTS: Biopsy samples sufficient for histologic diagnosis were obtained in 94(87.9%) of 107 patients, AG8 in 73(90.1%) of 81 patients and AGB and FNA in 21(80.8%) of 26 patients. 11 of 13 negative results were due to inadeguate specimen size for the histologic diagnosis or were composed of necrotic areas, and 2 of 13 negative results were obtained through nontarget tissue. 10 patients developed pneumothorax and 4 of them required chest tube insertion. Minimal hemoptysis was found in 3 patients. CONCLUSION: Percutaneous automated gun biopsy under fluoroscopic guidance was easy and simple method of obtaining specimens of good quality and quantity. It may be an useful procedure in the diagnosis of localized pulmonary lesions.


Subject(s)
Humans , Biopsy , Biopsy, Needle , Chest Tubes , Diagnosis , Hemoptysis , Needles , Pneumothorax
2.
Journal of the Korean Radiological Society ; : 109-114, 1995.
Article in Korean | WPRIM | ID: wpr-140891

ABSTRACT

PURPOSE: Percutaneous needle aspiration biopsy under the imaging guidance in the diagnosis of intrathoracic diseases has become a standard practice. Core tissue obtained by automated gun biopsy(AGB) is believed to be more diagnostic than materials from fine needle aspiration(FNA) by many cytopathologists. The authors evauated the role of automated gun biopsy in localized pulmonary lesions with respect to the its accuracy and complications. MATERIALS AND METHODS: We performed 107 percutaneous biopsies in localized pulmonary lesions under fluoroscopic guidance among 107 patients:AGB using 18G or 20G was done in 81 patients, and both AGB and FNA was done in 26 patients. RESULTS: Biopsy samples sufficient for histologic diagnosis were obtained in 94(87.9%) of 107 patients, AG8 in 73(90.1%) of 81 patients and AGB and FNA in 21(80.8%) of 26 patients. 11 of 13 negative results were due to inadeguate specimen size for the histologic diagnosis or were composed of necrotic areas, and 2 of 13 negative results were obtained through nontarget tissue. 10 patients developed pneumothorax and 4 of them required chest tube insertion. Minimal hemoptysis was found in 3 patients. CONCLUSION: Percutaneous automated gun biopsy under fluoroscopic guidance was easy and simple method of obtaining specimens of good quality and quantity. It may be an useful procedure in the diagnosis of localized pulmonary lesions.


Subject(s)
Humans , Biopsy , Biopsy, Needle , Chest Tubes , Diagnosis , Hemoptysis , Needles , Pneumothorax
3.
Journal of the Korean Radiological Society ; : 461-468, 1995.
Article in Korean | WPRIM | ID: wpr-82507

ABSTRACT

PURPOSE: The residual intrahepatic stones with biliary strictures are difficult to remove percutaneously via T-tube tract after surgery in patients with recurrent pyogenic cholangitis. We evaluated the effectiveness of percutaneous balloon dilatation of benign biliary strictures. MATERIALS AND METHODS: The balloon dilatations with 6-12mm angioplasty balloon catheter and stone extractions were performed via a T-tube tract after surgical treatment in 15 patients with recurrent pyogenic cholangitis. The balloons were inflated for 3-4minutes under 5 atm. until disappearance of waist of the stricture site, from one to seven session. After balloon dilatation, residual stones were extracted with saline irrigation or stone basket. RESULTS: Among total 42 strictures, the balloon dilatation was succesful in 27 strictures(64.3%), partially successful in 12 strictures(28.6%), and failed in three strictures(7.1%). Single or central biliary strictures were dilated easily rather than multiple ductal strictures. Of 26 sites with residual intrahepatic stones, stone extraction was complete in 17 sites(65.4%), incomplete in seven sites(26.9%) due to impacted or large stone and acute ductal angulation, and failed in two sites(7.7%). CONCLUSION: Percutaneous balloon dilatation of benign biliary strictures is an effective procedure for extraction of residual intrahepatic stones associated with recurrent pyogenic cholangitis.


Subject(s)
Humans , Angioplasty , Catheters , Cholangitis , Constriction, Pathologic , Dilatation
SELECTION OF CITATIONS
SEARCH DETAIL