Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Anesthesia and Pain Medicine ; : 104-111, 2022.
Article in English | WPRIM | ID: wpr-925403

ABSTRACT

The GlideScope® videolaryngoscope (GVL) is widely used in patients with difficult airways and provides a good glottic view. However, the acute angle of the blade can make insertion and advancement of an endotracheal tube (ETT) more difficult than direct laryngoscopy, and the use of a stylet is recommended. This randomized controlled trial compared Parker Flex-It™ stylet (PFS) with GlideRite® rigid stylet (GRS) to facilitate intubation with the GVL in simulated difficult intubations. Methods: Fifty-four patients were randomly allocated to undergo GVL intubation using either GRS (GRS group) or PFS (PFS group). The total intubation time (TIT), 100-mm visual analog scale (VAS) for ease of intubation, success rate at the first attempt, use of laryngeal manipulation, tube advancement rate by assistant, and complications were recorded. Results: There was no significant difference between the GRS and PFS groups regarding TIT (50.3 ± 12.0 s in the GRS group and 57.8 ± 18.8 s in the PFS group, P = 0.108). However, intubation was more difficult in the PFS group than in the GRS group according to VAS score (P = 0.011). Cases in which the ETT was advanced from the stylet by an assistant, were more frequent in the GRS group than in the PFS group (P = 0.002). The overall incidence of possible complications was not significantly different. Conclusions: In patients with a simulated difficult airway, there was no difference in TIT using either the PFS or GRS. However, endotracheal intubation with PFS is more difficult to perform than GRS.

2.
Journal of Korean Medical Science ; : e323-2018.
Article in English | WPRIM | ID: wpr-719074

ABSTRACT

BACKGROUND: Vitamin K antagonist (VKA) to prevent thromboembolism in non-valvular atrial fibrillation (NVAF) patients has limitations such as drug interaction. This study investigated the clinical characteristics of Korean patients treated with VKA for stroke prevention and assessed quality of VKA therapy and treatment satisfaction. METHODS: We conducted a multicenter, prospective, non-interventional study. Patients with CHADS2 ≥ 1 and treated with VKA (started within the last 3 months) were enrolled from April 2013 to March 2014. Demographic and clinical features including risk factors of stroke and VKA treatment information was collected at baseline. Treatment patterns and international normalized ratio (INR) level were evaluated during follow-up. Time in therapeutic range (TTR) > 60% indicated well-controlled INR. Treatment satisfaction on the VKA use was measured by Treatment Satisfaction Questionnaire for Medication (TSQM) after 3 months of follow-up. RESULTS: A total of 877 patients (age, 67; male, 60%) were enrolled and followed up for one year. More than half of patients (56%) had CHADS2 ≥ 2 and 83.6% had CHA2DS2-VASc ≥ 2. A total of 852 patients had one or more INR measurement during their follow-up period. Among those patients, 25.5% discontinued VKA treatment during follow-up. Of all patients, 626 patients (73%) had poor-controlled INR (TTR < 60%) measure. Patients' treatment satisfaction measured with TSQM was 55.6 in global satisfaction domain. CONCLUSION: INR was poorly controlled in Korean NVAF patients treated with VKA. VKA users also showed low treatment satisfaction.


Subject(s)
Humans , Male , Atrial Fibrillation , Drug Interactions , Follow-Up Studies , International Normalized Ratio , Prospective Studies , Risk Factors , Stroke , Thromboembolism , Vitamin K , Vitamins
3.
Anesthesia and Pain Medicine ; : 394-397, 2017.
Article in English | WPRIM | ID: wpr-136419

ABSTRACT

Endotracheal intubation is the gold standard for airway management in general anesthesia. However, airway patency is not guaranteed by keeping the endotracheal tube (ETT) in place. Sometimes, the ETT itself may become a cause of airway obstruction; there are some reports on airway obstruction related to reinforced tube malfunction. We report a rare case with an obstruction of reinforced endotracheal tubes caused by dissection of the internal wall. Recognition of the possibility of airway obstruction due to a rare cause and monitoring patients vigilantly during anesthesia is very important for patient safety.


Subject(s)
Humans , Airway Management , Airway Obstruction , Anesthesia , Anesthesia, General , Intubation, Intratracheal , Patient Safety
4.
Anesthesia and Pain Medicine ; : 394-397, 2017.
Article in English | WPRIM | ID: wpr-136418

ABSTRACT

Endotracheal intubation is the gold standard for airway management in general anesthesia. However, airway patency is not guaranteed by keeping the endotracheal tube (ETT) in place. Sometimes, the ETT itself may become a cause of airway obstruction; there are some reports on airway obstruction related to reinforced tube malfunction. We report a rare case with an obstruction of reinforced endotracheal tubes caused by dissection of the internal wall. Recognition of the possibility of airway obstruction due to a rare cause and monitoring patients vigilantly during anesthesia is very important for patient safety.


Subject(s)
Humans , Airway Management , Airway Obstruction , Anesthesia , Anesthesia, General , Intubation, Intratracheal , Patient Safety
5.
Korean Journal of Anesthesiology ; : 272-275, 2013.
Article in English | WPRIM | ID: wpr-49129

ABSTRACT

Patient-controlled analgesia (PCA) provides excellent pain control and high stability, thereby minimizing the incidence of adverse effects. However, one of our patients experienced respiratory depression and hypotension within 30 minutes of initiation of PCA therapy. We discovered that machine malfunction caused continuous activation of the PCA button, resulting in a drug overdose. The PCA machine was sent to the manufacturer, who found an electrical short in the PCA button. All PCA units of the same make and model were immediately removed from hospitals and replaced with redesigned units without defects in the PCA button. We have used the improved machines without any problems. The purpose of this report is to raise awareness of this type of malfunction in PCA units in order to help prevent adverse events in the future.


Subject(s)
Humans , Analgesia, Patient-Controlled , Drug Overdose , Hypotension , Incidence , Passive Cutaneous Anaphylaxis , Respiratory Insufficiency
SELECTION OF CITATIONS
SEARCH DETAIL