Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Radiol. bras ; 42(4): 209-214, jul.-ago. 2009. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-524397

ABSTRACT

OBJETIVO: Avaliar uma alternativa de braquiterapia para tumores do colo uterino acometendo a porção distal da vagina, sem aumentar os riscos de toxicidade. MATERIAIS E MÉTODOS: Estudo teórico comparando três diferentes aplicadores de braquiterapia intracavitária de alta taxa de dose: sonda intrauterina e cilindro vaginal (SC); sonda e anel associado ao cilindro vaginal (SA+C) e um aplicador virtual com sonda, anel e cilindro vaginal em um único conjunto (SAC). Foram prescritas doses de 7 Gy no ponto A e 5 Gy na superfície ou a 5 mm de profundidade na mucosa vaginal, mantendo as doses nos pontos de reto, bexiga e sigmoide abaixo dos limites de tolerância. Foram comparados os volumes englobados pelas isodoses de 50 por cento (V50), 100 por cento (V100), 150 por cento (V150) e 200 por cento (V200), respectivamente. RESULTADOS: Tanto SA+C quanto SAC apresentaram melhor distribuição de dose quando comparados ao aplicador SC. A distribuição de dose obtida com SA+C foi semelhante à do aplicador SAC, sendo V150 e V200 cerca de 50 por cento maiores para SA+C, todavia, dentro do cilindro. CONCLUSÃO: A utilização de SA+C em uma única aplicação em dois tempos pode ser uma alternativa de tratamento para pacientes que apresentam tumores de colo uterino com acometimento distal da vagina.


OBJECTIVE: To evaluate an alternative brachytherapy technique for uterine cervix cancer involving the distal vagina, without increasing the risk of toxicity. MATERIALS AND METHODS: Theoretical study comparing three different high-dose rate intracavitary brachytherapy applicators: intrauterine tandem and vaginal cylinder (TC); tandem/ring applicator combined with vaginal cylinder (TR+C); and a virtual applicator combining both the tandem/ring and vaginal cylinder in a single device (TRC). Prescribed doses were 7 Gy at point A, and 5 Gy on the surface or at a 5 mm depth of the vaginal mucosa. Doses delivered to the rectum, bladder and sigmoid colon were kept below the tolerance limits. Volumes covered by the isodoses, respectively, 50 percent (V50), 100 percent (V100), 150 percent (V150) and 200 percent (V200) were compared. RESULTS: Both the combined TR+C and TRC presented a better dose distribution as compared with the TC applicator. The TR+C dose distribution was similar to the TRC dose, with V150 and V200 being about 50 percent higher for TR+C (within the cylinder). CONCLUSION: Combined TR+C in a two-time single application may represent an alternative therapy technique for patients affected by uterine cervix cancer involving the distal vagina.


Subject(s)
Humans , Brachytherapy , Dosimetry , Uterine Cervical Neoplasms/radiotherapy , Uterine Cervical Neoplasms/therapy , Brachytherapy/instrumentation , Combined Modality Therapy , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL