Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Indian J Physiol Pharmacol ; 2014 Apr-Jun; 58(2): 174-77
Article in English | IMSEAR | ID: sea-152715

ABSTRACT

Physiological benefits of skin to skin care (STS) to newborns are known but there is scarcity of data on changes in physiological parameters like pulse rate, respiratory rate, SPO2 and blood pressure in mothers during STS. We hypothesize that STS is beneficial to mothers with respect to these parameters. Objective of this study was to assess the changes of these parameters in mothers while providing STS for one hour. STS was provided by 52 mothers for a total of 127 times and parameters were recorded at starting of STS, at 15 min, at 30 min, at 60 min of STS and at 5 min rest after stopping STS. There were no significant changes in pulse rate and SPO2 but blood pressure and respiratory rate reduced significantly during STS as compared to rest after stopping STS. Thus STS is physiologically beneficial to mothers.

2.
Indian Pediatr ; 2014 February; 51(2): 119-121
Article in English | IMSEAR | ID: sea-170170

ABSTRACT

Objective: To compare ultrasonography with chest radiograph to detect the level of endotracheal tube tip in intubated neonates. Design: Observational. Setting: Neonatal care unit of a teaching hospital. Participants: 53 neonates selected by convenience sampling. Intervention: Ultrasonography of chest was done with probe of 5 to 8 MHz using high parasternal view. The distance of the endotracheal tube tip to the arch of aorta on ultrasonography was compared with level of endotracheal tube tip in radiograph. Primary Outcome: Distance of endotracheal tube tip from the upper border of the arch of aorta on ultrasonography. Results: Endotracheal tube tip was visualised on ultrasonography within 0.5 - 1.0 cm distance from upper border of arch of aorta in 48 out of 53 neonates. This corresponded with the normal position of endotracheal tip in radiograph at T2 to T3. In 5 neonates, endotracheal tube tip was not visualized on ultrasonography and in all these newborns it was at higher level in radiograph. Conclusions: Distance of endotracheal tip to arch of aorta as measured on ultrasonography is helpful in early identification of the level of endotracheal tube tip.

3.
Indian Pediatr ; 2013 December; 50(12): 1153-1154
Article in English | IMSEAR | ID: sea-170098

ABSTRACT

Fluctuations in core body temperature beyond a narrow range are of concern as they indicate changed homeostasis. Thermoregulation remains a key aspect of neonatal care. New ‘non touch’ method of measuring temperature may reduce infection rate and discomfort of neonates. Body temperature of neonates admitted in Neonatal Intensive Care Unit was measured using axillary digital thermometer and a handheld infrared non touch thermometer. The two methods did not agree well (mean difference = -0.5, 95% limits of agreement: [-2.3, 1.2]). The agreement was similar with a negligible difference when patients in open care warmers were excluded (mean difference = -0.6, 95% limits of agreement: [-2.3, 1.1]). As the accuracy is unsatisfactory, the said technology needs further improvement before it can be adapted for routine patient care.

SELECTION OF CITATIONS
SEARCH DETAIL