Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of the Korean Ophthalmological Society ; : 352-360, 2022.
Article in Korean | WPRIM | ID: wpr-926318

ABSTRACT

Purpose@#To evaluate the clinical characteristics of Korean patients diagnosed with retinitis pigmentosa. @*Methods@#We retrospectively reviewed the medical records of patients diagnosed with retinitis pigmentosa from January 2014 to December 2019. We evaluated age, gender, the chief complaints, posterior subcapsular cataract status, abnormalities on optical coherence tomography, visual field test results, and electrooculograms. @*Results@#A total of 492 eyes of 246 patients were included. The mean patient age was 48.0 ± 16.0 years and the chief complaints were decreased vision and night blindness. The mean logarithm of the minimal angle of resolution (logMAR) best‐corrected visual acuity (BCVA) was 0.31 ± 0.50. The BCVA was 0.5 or better in 368 eyes (74.8%). A total of 328 (71.0%) of 462 eyes that underwent visual field testing exhibited visual field defects within 10º. The mean Arden ratio was 1.28 ± 0.28 for the 242 eyes that underwent electro‐oculography. Optical coherence tomography revealed vitreomacular traction/an epiretinal membrane, cystoid macular edema, and retinal thinning in 135 (27.4%), 48 (9.8%), and 112 (22.8%) eyes, respectively. The ellipsoid zone was intact in 222 eyes (45.1%), disrupted in 220 (44.7%), and absent in 50 (10.2%). @*Conclusions@#Most patients with retinitis pigmentosa exhibited visual acuity of 0.5 or better, but also had central visual field defects. Various abnormalities were noted on optical coherence tomography of most patients.

2.
Journal of the Korean Ophthalmological Society ; : 1189-1197, 2021.
Article in Korean | WPRIM | ID: wpr-901133

ABSTRACT

Purpose@#To investigate the outcomes of re-fixation after the first intraocular lens (IOL) scleral fixation. @*Methods@#We retrospectively reviewed the charts of patients who underwent second IOL scleral fixation and vitrectomy for dislocation of IOL after the first IOL scleral fixation. We compared the best-corrected visual acuity (BCVA) and spherical equivalent (SE) after 1 month of the first and second surgery, and noted the complications. @*Results@#We included 21 eyes that underwent second IOL scleral fixation: 13 eyes (61.9%) with IOL exchange and eight (38.1%) with one-haptic fixation. Mean BCVAs (LogMAR) were 0.17 ± 0.25 and 0.11 ± 0.23 after the first and second surgery, respectively (p = 0.073); mean SEs were -0.94 ± 1.69 and -0.58 ± 1.46 diopters after the first and second surgery, respectively (p = 0.076). Postoperative complications occurred in eight eyes (38.1%), including temporarily increased intraocular pressure and suture knots exposure. However, none of the complications required re-operation. @*Conclusions@#The outcomes of primary and secondary IOL fixation were similar, and there were no serious complications of the second surgery.

3.
Journal of the Korean Ophthalmological Society ; : 1189-1197, 2021.
Article in Korean | WPRIM | ID: wpr-893429

ABSTRACT

Purpose@#To investigate the outcomes of re-fixation after the first intraocular lens (IOL) scleral fixation. @*Methods@#We retrospectively reviewed the charts of patients who underwent second IOL scleral fixation and vitrectomy for dislocation of IOL after the first IOL scleral fixation. We compared the best-corrected visual acuity (BCVA) and spherical equivalent (SE) after 1 month of the first and second surgery, and noted the complications. @*Results@#We included 21 eyes that underwent second IOL scleral fixation: 13 eyes (61.9%) with IOL exchange and eight (38.1%) with one-haptic fixation. Mean BCVAs (LogMAR) were 0.17 ± 0.25 and 0.11 ± 0.23 after the first and second surgery, respectively (p = 0.073); mean SEs were -0.94 ± 1.69 and -0.58 ± 1.46 diopters after the first and second surgery, respectively (p = 0.076). Postoperative complications occurred in eight eyes (38.1%), including temporarily increased intraocular pressure and suture knots exposure. However, none of the complications required re-operation. @*Conclusions@#The outcomes of primary and secondary IOL fixation were similar, and there were no serious complications of the second surgery.

SELECTION OF CITATIONS
SEARCH DETAIL