Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Type of study
Language
Year range
1.
Scientific Journal of Kurdistan University of Medical Sciences. 2014; 19 (3): 94-102
in Persian | IMEMR | ID: emr-153021

ABSTRACT

Vitrification of ovarian tissue is an effective method for preservation of fertility. Many attempts have been made to improve cryopreservation conditions. The aim of this study was to compare the effects of two vitrification methods using two carrier systems; straw and cryolock, on the morphology of neonatal mouse ovarian tissue. In this experimental study we used NMRI 7-day-old mice. Their ovaries were excised and divided into non-vitrified, vitrified with straw, vitrified with cryolock and toxicity test groups. In vitrification group, the ovaries were dehydrated in a mixture of 40% ethylene glycol, 30% ficoll 70 and sucrose [EGFS40] for 5 min.Then they were put in a plastic straw or cryolock and were placed into liquid nitrogen and stored for one week. Whereas in the toxicity test group the ovaries were exposed to the cryoprotectant EGFS40 and warming solution procedure without using liquid nitrogen. Then we studied the morphology of ovarian follicles by means of light and electron microscopes. No significant differences were observed between the groups in regard to the percentages of primordialand primary follicles with normal morphology. But the percentages of normal preantral follicles in the vitrified group using straw were significantly lower than those of other groups. Ultrastructural studies showed signs of degeneration and nuclear shrinkage in follicular cells in some of the preantral follicles in vitrified group using straw. Vitrification of ovarian tissue using cryolock is more effective for preserveration of the normal morphology of ovarian tissue, compared to vitrification by using straw

2.
Journal of Iranian Anatomical Sciences. 2009; 6 (25-26): 627-631
in Persian | IMEMR | ID: emr-91764

ABSTRACT

Several variations of aortic arch have been reported yet. In present study another variation of aoictic arch was reported. Right subclavian artery arises from posterior surface of the distal end of the aortic arch we present a variation of an aorticarch in which right subclavian artery arises from posterior surface of the distal end of the aortic arch and passing behind esophagus to reach right side of neck. Conclusion: Review of literature showed that regarding origin of the artery this variation was reported for tile first time by the authors It seems that the artery narrowed the position the esophagus However there were not any other sign of side effect on anatomical structure and of their blood supply


Subject(s)
Humans , Subclavian Artery/abnormalities , Aorta/anatomy & histology , Aorta, Thoracic/anatomy & histology
SELECTION OF CITATIONS
SEARCH DETAIL