Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Neurology ; (12): 524-528, 2022.
Article in Chinese | WPRIM | ID: wpr-933820

ABSTRACT

The intestinal microbiota refers to the microbial group that exists in the intestine, and its composition disorder may affect human health. Many studies have found that intestinal microbiota and their metabolites may be closely related to the pathologies of Alzheimer′s disease (AD) through the gut-brain axis. This article will review the roles and possible mechanisms of lipopolysaccharide, functional bacterial amyloid proteins and bile acids, which are common metabolites of intestinal microbiota, in the pathogenesis of AD, and provide valuable information for exploring the pathogenesis of AD.

2.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 445-448, 2018.
Article in Chinese | WPRIM | ID: wpr-806617

ABSTRACT

Objective@#To investigate the characteristics of hearing loss in occupational noise-exposed workers in automotive manufacturing industry.@*Methods@#According to Technical Specifications for Occupational Health Surveillance (GBZ188-2014) , 530 noise-exposed workers were examined for health and pure tone audiometry during January to June, 2017, and the data were collected for analysis. Poisson regression analysis was used to analysis the relationship between work age and hearing loss.@*Results@#After correction of age and gender, pure-tone threshold of 500, 1 000, 2 000, 3 000, 4 000, 6 000 of the noise-exposed workers in the <3 year-exposure group were 20.15±3.60, 18.80±3.43, 18.54±3.38, 19.10±4.03, 20.32±6.79, 23.48±8.92 dB (A) ; the values in the 3-10 year-exposure group were 20.96±5.38, 19.25±4.76, 19.22±5.29, 20.17±7.50, 21.36±8.88, 25.39±11.60 dB (A) ; the values in the >10 year-exposure group were 20.18±3.67, 18.34±3.60, 18.36±4.25, 18.49±4.41, 20.32±9.24, 22.50±9.57 dB (A) . Poisson regression analysis showed that the relative risk (RR) of hearing loss of the noise-exposed workers compared with the noise-free workers was 4.38 (P<0.05) .@*Conclusion@#The noise-exposed workers in automotive manufacturing industry revealed hearing loss, which was associated with their actual working age of noise exposure.

3.
International Journal of Laboratory Medicine ; (12): 2055-2057, 2016.
Article in Chinese | WPRIM | ID: wpr-495730

ABSTRACT

Objective To evaluate the detection performance of the cobas8000 c702 fully automatic biochemical analyzer for de‐tecting the second generation Roche urine trace albumin (ALBU2) .Methods (1) The precise evaluation :with the allowable error stipulated by CLIA 88 as the basis ,the requirements were the repeat precision <1/4TEa ,and intermediate precision <1/3TEa;(2) the linear range and the evaluation of the reportable range :the EP6‐A scheme was adopted ,and extend to calculate the average re‐covery rate of dilution ,the clinical reportable range was evaluated by the average dilution recovery of 90% -110% ;(3) the carry o‐ver pollution assessment :the carry over pollution of serum albumin on urine trace albumin detection was evaluated by the judgment standard of carry over pollution rate of 0 .5% ;(4)the methodological comparative analysis :with SIEMENS BN Ⅱas the reference system ,the Roche Cobas 8000 C702 and the BN2 results were performed the correlation contrastive analysis .Results The repeat precision :low concentration CV=1 .98% .high concentration CV=1 .64% ;intermediate precision :low concentration CV=4 .35% , high concentration CV=1 .20% ;the linear range verification :the measurement range 5 .6-413 .55 mg/L ;clinical reportable range :in the maximum diluted multiples of 30 times ,the clinical reportable range was 5 .6-12 406 .5 mg/L ;the carry over pollution rate :serum albumin (42 .6 g/L) on urine trace albumin(6 .9 mg/L) ,the carry over pollution rate was 0 .28% ;the indoor comparison :in the concentration within 200 mg/L ,the regression line was Y=0 .896 X+5 .049 ,the correlation coefficient r2 =0 .994 4 ,the system shift was passed at the medical decision level .When the specimen concentration within 201-413 .55 mg/L ,the regression line was Y=0 .848X-10 .44 ,the correlation coefficient r2 =0 .917 ,the system shift was not passed at the medical decision level .Conclusion The detection of the Roche ALBU2 in the Cobas 8000 C702 platform can meet the clinical needs ,the comparison among different instruments has difference in different concentration ranges ,therefore the independent reference ranges should be established ac‐cording to the each instrument system .

SELECTION OF CITATIONS
SEARCH DETAIL