Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Main subject
Year range
1.
Acta Pharmaceutica Sinica ; (12): 2662-2670, 2022.
Article in Chinese | WPRIM | ID: wpr-941525

ABSTRACT

Glioblastoma (GBM) is the most common primary brain tumor, which is prone to recurrence and metastasis with poor prognosis. In recent years, immunotherapy has prolonged the survival of patients with GBM, providing a new option for the treatment of GBM. Target selection is very important for immunotherapy. Epidermal growth factor receptor variant III (EGFRvIII) is highly expressed on the surface of GBM cells in some patients, and EGFRvIII was not expressed in normal tissues. EGFRvIII are pivotal for the occurrence and progression of GBM, various targeted therapy including immunotherapy is promising to improve the efficacy of GBM. Currently, there are various approaches to target EGFRvIII, including humanized monoclonal antibodies, adoptive cell therapies and therapeutic vaccines. In this review, we focus on the preclinical and clinical findings of targeting EGFRvIII for GBM.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 496-502, 2022.
Article in Chinese | WPRIM | ID: wpr-956547

ABSTRACT

Objective:To investigate the short-term efficacy of anatomical calcaneal external fixator in the treatment of calcaneal fractures.Methods:A retrospective study was conducted of the 9 patients with calcaneal fracture who had been admitted to Department of Orthopedics, 920 Hospital of the PLA Joint Logistics Support Force between September 2019 and March 2020. There were 7 males and 2 females, aged from 23 to 66 years (mean, 41.3 years). The injury was caused by a fall from a height in 6 cases and a traffic accident in 3 cases. By the Sanders classification, there were 2 cases of type ⅡB, 2 cases of type ⅢAC, 3 type Ⅲ AB, one of type Ⅲ BC and one type Ⅳ. By the AO grading for closed soft tissue injury in the 8 closed fractures, there were 5 cases of grade Ⅰ and 3 cases of grade Ⅱ. The one open fracture was type ⅢB by the Gustilo-Anderson classification and treated with skin flap repair after debridement. All the 9 patients were treated with an anatomic calcaneal external fixator during stage-one or stage-two surgery (8 patients in stage-one and one in stage-two). The fracture union time for the patients was recorded; the ankle and hindfoot score of American Orthopedic Foot and Ankle Society (AOFAS) and the protocol of Association for the Study and Application of the Method of Ilizarov (ASAMI) were used at the last follow-up to assess the short-term efficacy.Results:Postoperative follow-up for the 9 patients ranged from 6 to 18 months (mean, 9.8 months). The duration of fracture union in the 9 patients ranged from 2 to 4 months (mean 2.8 months). The AOFAS ankle and hindfoot score at last follow-up ranged from 79 to 93 points (mean, 84.7 points) for the male patients (6 excellent and one good), and from 82 to 91 points (mean, 86.5 points) for the female patients (one excellent and one good). According to the ASAMI protocol at last follow-up, the short-term efficacy was rated as excellent in 6 cases, as good in 2 cases and as fair in one. The patients with closed fracture could get out of bed for rehabilitation on day 3 after surgery. None of the patients experienced such complications as pin tract infection and osteomyelitis during follow-up.Conclusion:The anatomic external calcaneal fixator demonstrates fine short-term efficacy in the treatment of calcaneal fractures, due to its advantages like anatomical configuration, a limited number of implants, and a possibility of partial weight-bearing for exercises on the third postoperative day.

3.
Chinese Journal of Orthopaedic Trauma ; (12): 478-482, 2022.
Article in Chinese | WPRIM | ID: wpr-956544

ABSTRACT

Objective:To investigate the clinical effects of Ilizarov external fixation combined with bone surface roughening technique in the treatment of tibial dystrophic nonunion.Methods:The data were retrospectively studied of the 11 patients with tibial dystrophic nonunion who had been treated at Department of Orthopedics, 920 Hospital of the Joint Logistic Support Force of PLA from April 2018 to January 2021. They were 7 males and 4 females, aged from 32 to 61 years (average, 44.6 years). Their last surgical fixation before admission was Hoffman Ⅱ external fixation in 6 cases and locking plate internal fixation in 5 cases. The time from their last operation to the present operation ranged from 9 to 26 months (average, 14.2 months). After treatment by Ilizarov external fixation combined with bone surface roughening technique, the 11 patients started weight-bearing walking with double crutches from the second day after operation, gradually progressed to walking with a single crutch 2 months after operation, and resumed normal weight-bearing walking without any crutch 3 months after operation.Results:All the 11 patients were followed up for 12 to 30 months (average, 20.0 months). The time for bearing Ilizarov external fixation ranged from 6 to 10 months (average, 8.6 months). Mild pin track infection occurred in 4 cases but was healed by pin track rinse with normal saline; moderate pin track infection happened in another 2 cases but responded to oral amoxicillin capsules for one week in addition to pin track rinse with normal saline. All the bone dystrophic nonunion was cured after 6 to 10 months (average, 8.6 months). By the bone criteria of Association for Study and Application of Method of Ilizarov (ASAMI), the efficacy was excellent in 8 cases, good in 2 and fair in one at the last follow-up; by the limb function criteria of ASAMI, the efficacy was excellent in 9 cases and good in 2 at the last follow-up.Conclusion:Ilizarov external fixation combined with bone surface roughening technique is an effective treatment of tibial dystrophic nonunion.

4.
Braz. j. med. biol. res ; 54(11): e11503, 2021. graf
Article in English | LILACS | ID: biblio-1285661

ABSTRACT

The mixture of ketamine and xylazine is widely used for the auditory brainstem response (ABR) measurement. Esketamine is twice as potent as ketamine. Our objective was to assess the influence of esketamine in mice undergoing cochlear function measurement including ABR and distortion product otoacoustic emission (DPOAE) measurement. C57Bl/6J mice were treated with an equivalent dose of analgesia and received either a single intraperitoneal (ip) injection of 100 mg/kg ketamine and 25 mg/kg xylazine or 50 mg/kg esketamine and 25 mg/kg xylazine. Hearing thresholds, peak latencies of waves I and V, and DPOAE thresholds were recorded. Time to loss of righting and time to regain righting were also assessed. We found that hearing thresholds, the peak latencies of waves I and V, and DPOAE thresholds were similar between the two groups (all P>0.05). Time to regain righting was significantly shorter in the esketamine group (P<0.001) than in the ketamine group. We concluded that when using equivalent doses of analgesia, esketamine may be an ideal substitute for ketamine during cochlear function test.


Subject(s)
Animals , Rabbits , Ketamine , Xylazine , Evoked Potentials, Auditory, Brain Stem , Otoacoustic Emissions, Spontaneous
5.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 475-481, 2020.
Article in Chinese | WPRIM | ID: wpr-856342

ABSTRACT

Objective: The anatomical calcaneal external fixator was designed by measuring and calculating the morphological data of the heel. Methods: A total of 100 normal people were randomly selected to obtain 200 hind foot data, including 45 males and 55 females, with an average age of 43.9 years (range, 19-67 years). According to the principles of human engineering and local anatomy, the morphological data of the heel in the weight-bearing standing position and supine position were measured with the direct measurement mode. The heel length, heel width, heel height, medial ankle height, lateral ankle height, and calcaneal pitch angle (CPA) were measured by vernier calipers and ulnar markers in weight-bearing standing position, and the gender groups and left and right foot groups were compared; the shape of the hind foot in the supine position was measured by three-dimensional (3D) dot matrix inverse model method. According to the stereoscopic data of the comprehensive anatomical morphology of the heel, the anatomical calcaneal external fixator was designed with AutoCAD 2019 and other 3D industrial design softwares. Results: The measurements of shoe size, heel length, heel width, heel height, medial ankle height, lateral ankle height, and CPA in male were significantly higher than those in female ( P<0.05). There was no significant difference between the left and right feet in the other indexes except that the height of the medial malleolus of the left foot was significantly lower than that of the right foot ( t=-2.827, P=0.005). The measurement of 3D dot matrix inverse model in supine position showed that the heel part was non-circular arc edge, and many groups of arc edges fluctuate in a limited range. Based on the above data, an anatomical calcaneal external fixator was designed, which could fit the anatomic radian in theory, so as to be flexible in configuration. On this basis, the ordinary configuration, compression configuration, and orthodontic configuration were designed to meet the treatment needs of calcaneal fractures in different degrees. The ordinary configuration was suitable for patients with Sanders Ⅰ, ⅡA, and ⅡB calcaneal fractures with no or slight displacement of intra-articular fractures; the ordinary configuration was mainly used for simple fixing. The compression configuration was suitable for patients with Sanders ⅡC, ⅢA, and ⅢB, tongue fractures, and avulsion fractures with severe displacement of intra-articular fractures; the compression configuration used obliquely drawn console wires to fix the displaced bones. The orthodontic configuration was suitable for patients with Sanders ⅢC and Ⅳ calcaneal fractures with severe displacement of intra-articular fractures or severe calcaneal bone defects; the orthodontic configuration was a multi-module design, which took into account the stable fixation of the fracture and the arbitrary adjustment of the joint fixation angle. Conclusion: The hind foot is special for morphology, so the external fixator designed based on the vernier caliper measurement method and 3D dot matrix measuring plate measurement method is an anatomical type and its configuration can theoretically meet stable and flexible clinical needs.

6.
Chinese Journal of Orthopaedic Trauma ; (12): 264-268, 2019.
Article in Chinese | WPRIM | ID: wpr-745109

ABSTRACT

Objective To explore the clinical application of our self-designed controllable and portable double-pin traction device on calf in the treatment of tibiofibular fractures.Methods Our controllable and portable double-pin traction device on calf was designed to fulfill the purpose of traction and address current problems in traction for tibiofibular fractures.This device is composed of double-hole connectors,nuts of various specifications,traction pin sleeves,2 transfixion pins and 2 threaded rods for traction.The transfixion pins are fixed at conventional traction positions.The threaded rods for traction are paralleled to the long axis of lower limb and located on both sides of the calf.Bone ends can be distracted by adjusting the nut of M8 width and the speed of pulling can be controlled.This device can be used not only for rapid traction during surgery but also for slow traction preoperatively.It was applied in the 30 patients with tibiofibular fracture who had been treated at Department of Orthopaedic Surgery,920th Hospital of Joint Logistic Support Force from January to December 2017.Their radiographs were taken before traction and at 3 and 6 days after traction to observe the changes in overlapped fracture ends and fracture gap.The lengths of distraction were measured.After limited open reduction,fracture gaps and tensions of surrounding soft-tissues were observed.Results Their radiographs before and after traction demonstrated that their overlapped and displaced fracture ends were distracted more or less.The length of distraction ranged from 7.2 mm to 45.8 mm (mean,23.1 mm);it was < 15 mm in 6 cases,between 15 mm and 30 mm in 18,between 31 mm and 45 mm in 5,and > 45 mm in one.Their radiographs showed that regular traction for 6 days was more obvious than that for 3 days.The limited open reduction revealed that the gap between fracture ends was expanded,the soft-tissue tension effectively relaxed,the overlapping of fracture ends diminished,and the dissection of surrounding soft-tissue and periosteum decreased,leading to less difficulty in reduction.In fractures near the joint or involving the articular surface,the joint space was expanded.The 30 patients were followed up for one to 16 months (mean,5.8 months).No such complications as pin site infection,traction fracture or osteomyelitis was observed.Conclusion Our self-designed controllable and portable double-pin traction device on calf is effective and advantageous,because it is simple,easy,light in weight,and controllable for traction speed.

7.
Journal of Preventive Medicine ; (12): 325-327,333, 2015.
Article in Chinese | WPRIM | ID: wpr-792389

ABSTRACT

Objective To learn the immunity level of Neisseria meningitides (Nm) serogroup W1 35 among healthy population.Methods A total of 410 children aged 0 -14 years were selected by stratified random sampling method in Zhuji city.The polysaccharide antibody IgG level of Nm serogroup W1 35 was detected by ELISA.The antibody concentrations more than 2 μg/mL were identified as positive.Results The geometric mean concentration (GMC)was 1.46 ±0.25 μg/mL and the W1 35 -antibody positive rate was 4.63%.There was no difference on antibody GMC and the W1 35 -antibody postive rate among different region and gender groups.There were statistical differences on antibody GMC among different age groups (P<0.05).The antibody GMT in the age group 15 -34(1.63 ±0.28 μg/mL )was significantly higher than that in other age groups(P <0.05),and the antibody GMT in the age group 1.5 -4 (1.37 ±0.19 μg/mL)was significantly lower than that in the age group 5 -14 (P <0.05).The antibody GMT were significantly lower in the elderly (≥60 years old)than that in the age group <10 and 5 -14(P <0.05).Conclusion The immunity level of Nm serogroup W1 35 among healthy population is low,and it is suggested to be immunized by the vaccines which contained Nm W1 35.

SELECTION OF CITATIONS
SEARCH DETAIL