Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Article in Chinese | WPRIM | ID: wpr-617540

ABSTRACT

Subthalamic nucleus (STN) deep brain stimulation (DBS) has become an important surgical treatment of Parkinson disease, but its exact mechanism is still unclear.In this study, a 16-channel implantable microelectrode array (MEA) was prepared by micro-electromechanical system (MEMS) technique and later modified with platinum black/reduced Graphene Oxide/Nafion (Pt/RGO/Nafion) nanocomposites.Extracellular dopamine (DA) content and spike of dorsal striatum neurons were synchronously recorded before and after STN stimulation.The results showed that the dopamine content began to increase within 20 s after electrical stimulation and dropped to normal level after about 50 s, with the highest rising concentration of 1.72 μmol/L.At the same time, there was an increased spike activity of interneurons in the dopamine ascending phase, and the spike firing rate of medium spiny projection neurons (MSNs) was high when the concentration of DA was higher than the normal level.The MEA sensor can simultaneously record dopamine flux and physiological signals in situ, thus providing an ideal tool for neural information detection.

2.
Article in Chinese | WPRIM | ID: wpr-503579

ABSTRACT

A dual-mode recording system used for synchronous detection of neuroeletrical and neurochemical signals was developed, and a dual-mode synchronous detection experiment was carried out using the instrument. The device comprised 64-channel neuroelectricity recording module with voltage resolution of 0. 3 μV and 4-channel neurochemistry recording module with current resolution of 1 pA. The software had many basic features, including Spike separation and sort, chronoamperometry, cyclic voltammetry, etc. In particular, the software could observe and analyze the dual-mode neural signals synchronously. The performance of the system was demonstrated in the single mode detection experiments. In neuroeletrical experiments, 64-channel simulate neural signals were detected and the signal to noise ratio ( S/N) of Spike recorded from cortex of Sprague-Dawley ( SD ) rat was 6. In the K3 [ Fe ( CN )6 ] and ascorbic acid measurement experiments, the current response of K3 [ Fe ( CN)6 ] in the range of 0. 1-10 mmol/L was obtained by cyclic voltammetry, with a correlation coefficient of 0. 9889, and the current response of ascorbic acid ( concentration:10-800 μmol/L) by chronoamperometry increased linearly with a correlation coefficient of 0. 9841. Based on the rat model of global cerebral ischemia, a dual-mode detection experiment was carried out. In the experiment, the neuroelectrical and neurochemical signals were synchronously recorded in the SD rat primary visual cortex. According to the experimental results, we got the conclusion that the concentration of ascorbic acid negatively related to the Spike firing in the SD rat primary visual cortex.

3.
China Medical Equipment ; (12): 67-69,70, 2016.
Article in Chinese | WPRIM | ID: wpr-604314

ABSTRACT

Objective: To evaluate the diagnosis value of percutaneous puncture biopsy technique under CT guiding in clinical pathological changes of breast. Methods:46 patients with breast lumps or nodules, including six cases of pleural disease, were carried out percutaneous puncture biopsy under CT guide, where a coaxial Angiotech 17G trocar together with BiopincelSG were used in the puncture process. Results: 44 cases of pathological findings were acquired and the diagnosis ratio was 93.4%, including 9 cases of squamous cell carcinoma, 24 cases of adenocarcinoma, 3 cases of small cell carcinoma, 1 case of metastatic tumor, 1 case of tuberculosis cases, 5 cases of inflammation and 1 case of normal reflexed pleura. 2 cases have no clear diagnosis. Conclusion: The percutaneous lung biopsy technique under CT guide has the merits of less diagnosis trauma, high diagnosis accuracy and high clinical application value.

4.
Article in Chinese | WPRIM | ID: wpr-467591

ABSTRACT

High extracellular potassium can induce spreading depression-like depolarizations, elevations of extracellular glutamate and even neuronal death in normal brain. To investigate the contribution of high potassium in vivo, a microelectrode arrays ( MEAs ) probe integrated with recording sites for glutamate concentration (50í150 μm) and local field potential ( LFP) ( diameter=15 μm) was fabricated by Micro-electro-mechanical-systems ( MEMS) technologies. We implanted the MEA probe acutely in the rat brain and exposed the brain to a high potassium solution. During these multi-modal recordings, it was observed that high potassium elevated extracellular glutamate while suppressing the LFP irreversibly. This is one of the first studies in which a dual mode MEA probes is applied in vivo for neuronal death, and it is concluded that our MEA probes are capable of examining specific spatiotemporal relationships between electrical and chemical signaling in the brain.

5.
Article in Chinese | WPRIM | ID: wpr-457798

ABSTRACT

A wireless electrochemical recording device was designed for in_vivo neurotransmitters real_time detection. Low_power microcontroller MSP430 was chosen as main control unit in hardware system. Other modules were current detection module, waveform generator module and data transceiver module. This device had the merits of small size (2. 3 cm×1. 8 cm×0. 6 cm) and low power consumption. Firmware program design was based on uC/OS operating system. Combined with the PC software, the device could achieve online display and analysis of the recording data. For neurotransmitter detecting needs, the device implemented fast_scan cyclic voltammetry ( FSCV) and fixed_potential amperometry. By using fast_scan cyclic voltammetry method, a linear relationship ( R=0. 99 ) between the concentration of dopamine and response current was acquired in the range of 5. 0×10-7-7. 0×10-5 mol/L. In the in_vivo experiments, the electrically evoked dopamine was recorded in the caudate_putamen area of brain in rats. Experimental results showed that the system had high detection accuracy, which could realize qualitative and quantitative analysis of the brain neurotransmitter. This work would have a broad application prospect in the field of neuroscience research.

6.
Article in Chinese | WPRIM | ID: wpr-454855

ABSTRACT

The nano-structure TiN was modified on the laboratory self-made planar microelectrode array pMEA by magnetron sputtering method. The performance of modified pMEA was investigated. Research on neuroelectrical and neurochemical recording was studied in vitro. The impedance of the modified pMEA was decreased almost one order of magnitude, and the background noise level was reduced to ±6 μV. In the same testing environment, the signal-to-noise ratio (SNR) of modified electrodes was 1. 7 times of bare electrodes. The SNR of neuroelectrical recording on the brain slice of SD rats reached 10:1 , and the weak signal such as ±12 μV was separated easily. For neuroelectrical recordings, the detection limit of dopamine ( DA) solution reached 50 nmol/L with the 2:1 (S/N). During the concentration range of 0. 05-100 μmol/L, the linearly correlation coefficient of the DA oxidation currents was 0 . 998 . The modification of nano-structure TiN on pMEA reduced pMEA impedance and background noise level, meanwhile the SNR was increased. The weak signals of neuroelectrical and neurochemical recording were successfully recorded.

7.
Article in Chinese | WPRIM | ID: wpr-330522

ABSTRACT

This paper designed a ventilator control system to control proportional valves and motors. It used LabVIEW to control the object mentioned above and design ,validate, evaluate arithmetic, and establish hardware in loop platform. There are two system' s hierarchies. The high layer was used to run non-real time program and the low layer was used to run real time program. The two layers communicated through TCP/IP net. The program can be divided into several modules, which can be expanded and maintained easily. And the harvest in the prototype designing can be seamlessly used to embedded products. From all above, this system was useful in employing OEM products.


Subject(s)
Man-Machine Systems , Software , Software Design , Ventilators, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL