1.
Chinese Journal of General Practitioners ; (6): 49-51, 2020.
Article in Chinese | WPRIM | ID: wpr-798582

ABSTRACT

Clinical data of 23 children with atrial septal defect and pulmonary valvular stenosis admitted in Dalian Children′s Hospital during March 2015 to March 2018 were retrospectively analyzed. Twenty patients were treated with percutaneous closure of atrial septal defect through femoral vein first, then transthoracic echocardiography-guided balloon pulmonary valvuloplasty was performed; while 3 patients had no balloon pulmonary valvuloplasty after percutaneous closure of atrial septal defect. Patients were followed up by transthoracic echocardiography and all were doing well. The transvalvular pressure fell under 35 mmHg (1 mmHg=0.133 kPa) [(19.5±1.9)mmHg] in all patients, which was significantly lower than that before treatment [(62.0±7.8 mmHg)] (t=28.92, P<0.01). During follow-up, no residual shunt of atrial septal defect was found; and mild pulmonary regurgitation occurred in 3 cases. The study indicates that combined percutaneous treatment with transthoracic echocardiography guidance is effective and safe for children with atrial septal defect and pulmonary valvular stenosis. The pulmonary artery stenosis of some patients can be alleviated, after closuring of the atrial septal defect.

2.
Chinese Journal of General Practitioners ; (6): 49-51, 2020.
Article in Chinese | WPRIM | ID: wpr-870617

ABSTRACT

Clinical data of 23 children with atrial septal defect and pulmonary valvular stenosis admitted in Dalian Children′s Hospital during March 2015 to March 2018 were retrospectively analyzed. Twenty patients were treated with percutaneous closure of atrial septal defect through femoral vein first, then transthoracic echocardiography-guided balloon pulmonary valvuloplasty was performed; while 3 patients had no balloon pulmonary valvuloplasty after percutaneous closure of atrial septal defect. Patients were followed up by transthoracic echocardiography and all were doing well. The transvalvular pressure fell under 35 mmHg (1 mmHg=0.133 kPa) [(19.5±1.9)mmHg] in all patients, which was significantly lower than that before treatment [(62.0±7.8 mmHg)] ( t=28.92 , P<0.01). During follow-up, no residual shunt of atrial septal defect was found; and mild pulmonary regurgitation occurred in 3 cases. The study indicates that combined percutaneous treatment with transthoracic echocardiography guidance is effective and safe for children with atrial septal defect and pulmonary valvular stenosis. The pulmonary artery stenosis of some patients can be alleviated, after closuring of the atrial septal defect.

3.
Chinese Journal of Applied Clinical Pediatrics ; (24): 41-43, 2017.
Article in Chinese | WPRIM | ID: wpr-505115

ABSTRACT

Objective To investigate the efficacy and safety of percutaneous patent ductus arteriosus (PDA) closure via femoral vein solely under transesophageal echocardiography guidance.Methods From May 2014 to May 2015,28 patients(13 boys,15 girls) were selected in Dalian Children's Hospital Affiliated to Dalian Medical University with PDA closure via the femoral vein under transesophageal echocardiography guidance,with mean age (3.5 ± 2.6)years and mean body weight (16.0 ± 6.5) kg.The mean diameter of PDA was (7.1 ± 3.9) mm.Patients were all treated by percutaneous PDA closure solely by transesophageal echocardiography via the femoral vein.The effect of the procedures was evaluated by echocardiography.The transthoracic echocardiography,chest X-ray film,cardiogram at 1 month,3 months and 6 months after procedure were followed up.Results Twenty-seven cases were successfully treated with percutaneous PDA closure via the femoral vein solely under transesophageal echocardiography guidance,while 1 patient was closed by surgical closure with on-pump beating-heart because PDA occluder strayed into the left pulmonary artery on 1-month follow-up.The procedural time was (48.5 ±8.7) min.The mean diameter of PDA occluder was (8.2 ± 4.1) mm.Twenty-seven patients survived without peripheral vascular injury or complications such as residual shunt,arrhythmia and cardiac perforation.One patient was transformed to surgical closure.Hospitalization time was (2.5 ± 0.5) days.At one month follow-up,no complications such as residual shunt or pericardial effusion occurred.Conclusion Transesophageal echocardiography guided percutaneous PDA closure via the femoral vein approach is safe and effective without the damage from radiation and contrast agents,and aviods the use of femoral artery puncture.