Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Journal of Peking University(Health Sciences) ; (6): 193-199, 2022.
Article in Chinese | WPRIM | ID: wpr-936134

ABSTRACT

OBJECTIVE@#To automatically construct lips symmetry reference plane (SRP) based on posed smile, and to evaluate its advantages over conventional digital aesthetic design.@*METHODS@#Eighteen subjects' three-dimensional facial and dentition data were gathered in this study. The lips SRP of experimental groups were used with the standard weighted Procrustes analysis (WPA) algorithm and iterative closest point (ICP), respectively. A reference plane defined by experts based on regional ICP algorithm, served as the truth plane. The angle error values between the lips SRP of WPA algorithm in the experimental groups and the truth plane were evaluated in this study, and the lips SRP of ICP algorithm of the experimental groups was calculated in the same way. The lips SRP based on posed smile as a reference for aesthetic design and evaluate preliminary clinical application.@*RESULTS@#The average angle error between the lips SRP of WPA algorithm and the truth plane was 1.78°±1.24°, which was smaller than that between the lips SRP of ICP and the truth plane 7.41°±4.31°. There were significant differences in the angle errors among the groups (P < 0.05). In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile and the original symmetry plane by re-ference compared with the prosthetic design, the subjects' scores on the lips SRP of WPA algorithm based on posed smile (8.48±0.57) were higher than those on the original symmetry plane (5.20±1.31).@*CONCLUSION@#Automatically constructing the lips SRP of WPA algorithm based on posed smile was more accurate than ICP algorithm, which was consistent with the truth plane. Moreover, it can provide an important reference for oral aesthetic diagnosis and aesthetic analysis of the restoration effect. In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile can improve the patients' satisfaction in esthetic rehabilitation.


Subject(s)
Humans , Esthetics, Dental , Lip , Smiling , Tooth , Workflow
2.
Journal of Peking University(Health Sciences) ; (6): 62-68, 2020.
Article in Chinese | WPRIM | ID: wpr-942142

ABSTRACT

OBJECTIVE@#To explore the preliminary application of "biocopy function" in digital technology of temporary crown in severe tooth attrition, so as to reduce the difficulty of final restoration adjustment in severe tooth wear cases, and save clinical time.@*METHODS@#Twelve patients aged between 40 and 65 years with severe tooth attrition were recruited in this study. The experimental group (6 cases, 3 females and 3 males) used the method of digital copy of temporary restoration shape when making the final restoration, and the control group (6 cases, 3 females and 3 males) used the traditional method to make the final restoration. The mean time of central occlusal adjustment and protrusive and lateral occlusal adjustment of each crown, the number of follow-up visits of the patients were recorded and statistically analyzed. The occlusal comfort of the first and the third months after wearing the prosthesis was evaluated by the patients, and the difference of the occlusal comfort of the final prosthesis made by the two methods was compared (the full score was 10 points). The occlusal adjustment time and occlusal comfort score were used as measurement data. Single sample t test was used. The number of follow-up visits was count data. Rank sum test was used for non-normal continuous variables.@*RESULTS@#The mean occlusal time of each crown adjustment in the experimental group was significantly lower than that in the control group (P < 0.01), and the median number of follow-up visits in the experimental group was lower than that in the control group (P < 0.01). The average occlusal comfort score of the experimental group was higher than that of the control group at the first time (P < 0.01). After three months of crown wearing, the median occlusal comfort score of the experimental group was higher than that of the control group (P < 0.05).@*CONCLUSION@#In the case of severe tooth attrition, it is feasible to use the "biocopy function" in the design software to design the final prosthesis, which is conducive to reduce the difficulty of adjustment and achieve predictable functional and aesthetic effects, which is of great significance to save clinical time and improve the accuracy of restoration.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Computer-Aided Design , Crowns , Tooth
3.
Journal of Peking University(Health Sciences) ; (6): 105-110, 2019.
Article in Chinese | WPRIM | ID: wpr-941778

ABSTRACT

OBJECTIVE@#To establish a complete workflow of digital design and manufacturing occlusal splint for sleep bruxism, which can be preliminarily applied in clinical use, thus observe the clinical efficacy.@*METHODS@#Twenty-four patients with sleep bruxism were recruited in the study and randomly divided into two groups by using random number tables. Digital-occlusal-splint (experimental group) treatment plan and traditional-occlusal-splint (control-group) treatment plan were carried out for each group, respectively. For experimental group, digital models of patients' both dental arches and the occlusion relationship after elevation were captured using an intraoral scanner. The occlusal splint was carried out by computer aided design/computer aided manufacturing (CAD/CAM), including splint designing and milling. For control group, the traditional soft occlusal splint was fabricated by vacuum laminator. The two kinds of occlusal splints were tried in the patients from each group, and the occlusal contacts were tested respectively by T-scan analysis system, which recorded the changes of occlusal indicators in the two groups. The retention, appearance and occlusal comfort degree were evaluated by the two groups of patients. Mann-Whitney test was performed with IBM SPSS 20.0 software, and bilateral test was performed. P<0.05 was considered to be statistically significant.@*RESULTS@#The complete workflow of digital design and manufacturing occlusal splint was successfully established. During the clinical use, there was no statistical difference in the retention evaluation of two kinds of occlusal splints between the two groups of patients (Z=-0.538, P=0.590). The appearance score (Z=2.038, P=0.042) and the occlusal comfort score (Z=-2.579, P=0.010) of the experimental group were higher than those of the control group, with statistically significant differences. The T-scan analysis results showed that only the second molar on both sides of the traditional occlusal splint had occlusal contact in intercupsal position, while the digital occlusal splint had stable and bilaterally balanced contact between the maxillary and mandibular teeth. Furthermore, the occlusal force was uniformly distributed in the experimental group.@*CONCLUSION@#The complete workflow of digital occlusal splint improves the occlusal design, greatly simplifies and optimizes the traditional process of making occlusal splint. This new method is resource-saving and environmental-friendly, and it is able to serve patients more conveniently and efficiently.


Subject(s)
Humans , Dental Arch , Dental Occlusion , Occlusal Splints , Sleep Bruxism , Workflow
4.
China Occupational Medicine ; (6): 437-441, 2016.
Article in Chinese | WPRIM | ID: wpr-876970

ABSTRACT

OBJECTIVE: To explore the relationship of job stressors,the coping styles and social supports among medical workers in primary and secondary schools in Guangzhou City. METHODS: A total of 211 medical workers from 168 primary and secondary schools in Guangzhou City were selected as study subjects by random sampling method. The relationship of job stressors,the coping styles and social supports were investigated by the Scale for Occupational Stressors in Clinical Medical Workers,the Ways of Coping Questionnaire and Social Support Questionnaire. RESULTS: The total scale score of job stressors was( 90. 5 ± 16. 7),medium level and above of stress scale( total score≥95. 0) accounted for 41. 2%( 87 /211). The median scores of positive coping dimension score and negative coping dimension score were 2. 0 and 1. 0,the total score of social support was( 41. 2 ± 9. 8). The medium level and above of social support scale( total score ≥32. 0)accounted for 86. 3%( 182 /211). The multiple stepwise regression analysis results showed that the clinicians and the parttime school doctors had higher job stress than those medical workers who were not majored in clinic and full-time school doctors( P < 0. 05). The medical workers with higher monthly income and higher score of social support showed higher job stress( P < 0. 05). The medical workers with higher social support had lower job stress( P < 0. 05). CONCLUSION: High job stress was found in the medical workers in primary and secondary schools in Guangzhou City. Positive coping styles and social supports has important role in relieving job stress of school medical workers.

5.
Journal of Breast Cancer ; : 25-32, 2014.
Article in English | WPRIM | ID: wpr-7630

ABSTRACT

PURPOSE: The universal organic solvent dimethyl sulfoxide (DMSO) can be used as a differentiation inducer of many cancer cells and has been widely used as a solvent in laboratories. However, its effects on breast cancer cells are not well understood. The aim of this study is to investigate the effect and associated mechanisms of DMSO on mouse breast cancer. METHODS: We applied DMSO to observe the effect on tumors in a mouse breast cancer model. Tumor-associated macrophages (TAMs) were tested by flow cytometry. Ex vivo tumor microenvironment was imitated by 4T1 cultured cell conditioned medium. Enzyme-linked immunosorbent assays were performed to detect interleukin (IL)-10 and IL-12 expression in medium. To investigate the cytotoxicity of DMSO on TAMs, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assays were performed. RESULTS: We found that DMSO produced tumor retardation when injected into mouse peritoneal cavities in a certain concentration range (0.5-1.0 mg/g). Furthermore, as detected by flow cytometry, TAM subtypes were found to be transformed. We further imitated a tumor microenvironment in vitro by using 4T1 cultured cell conditioned medium. Similarly, by using low concentration DMSO (1.0%-2.0% v/v), TAMs were induced to polarize to the classically activated macrophage (M1-type) and inhibited from polarizing into the alternatively activated macrophage (M2-type) in the conditioned medium. IL-10 expression in tumors was reduced, while IL-12 was increased compared with the control. Furthermore, we reported that 2.0% (v/v) DMSO could lead to cytotoxicity in peritoneal macrophages after 48 hours in MTT assays. CONCLUSION: Our findings suggest that DMSO could exert antitumor effects in 4T1 cancer-bearing mice by reversing TAM orientation and polarization from M2- to M1-type TAMs. These data may provide novel insight into studying breast cancer immunotherapy.


Subject(s)
Animals , Mice , Breast Neoplasms , Breast , Cells, Cultured , Culture Media, Conditioned , Dimethyl Sulfoxide , Enzyme-Linked Immunosorbent Assay , Flow Cytometry , Immunotherapy , Interleukin-10 , Interleukin-12 , Interleukins , Macrophages , Macrophages, Peritoneal , Tumor Microenvironment
6.
International Journal of Cerebrovascular Diseases ; (12)2006.
Article in Chinese | WPRIM | ID: wpr-680203

ABSTRACT

Transient ischemic attack(TIA)is a common ischemic cerebrovascular disease,and the incidence of secondary ischemic stroke and cardiovascular events is very high.It needs to be assessed and managed urgently.The article presents the contents of emergency assessment of TIA,and emphasizes the importance of overall assessment.

7.
National Journal of Andrology ; (12): 514-519, 2005.
Article in Chinese | WPRIM | ID: wpr-323320

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the objective index of the diagnosis of varicocele (VC) in infertile males by ultrasonography and the testis volume changes resulting from varicocele.</p><p><b>METHODS</b>Forty-six healthy male volunteers and 178 infertile men with left varicocele were detected by high frequency ultrasound. According to the clinical data and ultrasonographic results, the 178 VC patients were divided into 4 groups, SVC group (45 cases), VC I group (44 cases), VC II group (48 cases), and VC III group (41 cases).</p><p><b>RESULTS</b>(1) The differences in DR, DV, Vmax, TR and testis volume between the right and the left sides were not statistically significant in the control group (P > 0.05). (2) The differences in DR, DV, Vmax and TR between the experimental and control groups as well as among the VC groups were statistically significant (P < 0.001). (3) The left testis volume was smaller than the right among the VC groups (P < 0.01). The right testis volume of the VC II and VC III groups was significantly smaller than that of the control group ( P < 0.05), and the left testis volume in the VC III group was significantly smaller than that of the SVC group (P < 0.05).</p><p><b>CONCLUSION</b>(1) High frequency ultrasound can detect the accurate diameter of the internal spermatic vein, hemodynamic index and testis volume of infertile men with VC, and hence help to screen the causes of male infertility. (2) Unilateral varicocele can cause a volume decrease in both testes, especially in the left. Both unilateral SVC and VC can cause testicular atrophy, and the more serious VC, the higher testicular atrophy.</p>


Subject(s)
Adult , Humans , Male , Infertility, Male , Diagnostic Imaging , Testis , Diagnostic Imaging , Ultrasonography, Doppler, Color , Varicocele , Diagnostic Imaging
8.
Chinese Journal of Stomatology ; (12): 230-232, 2003.
Article in Chinese | WPRIM | ID: wpr-253737

ABSTRACT

<p><b>OBJECTIVE</b>To prove the inhibitory effect of glass ionomer cement for orthodontic bonding on bacteria.</p><p><b>METHODS</b>Twenty-two persons were chosen randomly. In vivo, with the split-mouth technique, brackets were bonded with glass ionomer cement or composite resin respectively. Plaque samples were taken from the area of the adhesive one month after the placement of brackets and incubated for microbiologic analysis.</p><p><b>RESULTS</b>There was no significant difference in the amount of total anaerobic bacteria with the two materials. There were also no obvious reduction of the numbers of S. mutans (the composite: 2.4 x 10(10) CFU/L, the glass ionomer cement: 2.8 x 10(10) CFU/L, P = 0.673) and its proportion (percentage of total CFU) with the use of glass ionomer cement compared with the composite.</p><p><b>CONCLUSIONS</b>There was no long term inhibitory effect on bacteria adjacent to glass ionomer cement for orthodontic bonding.</p>


Subject(s)
Adolescent , Child , Female , Humans , Male , Composite Resins , Pharmacology , Dental Plaque , Microbiology , Glass Ionomer Cements , Pharmacology , Lactobacillus , Orthodontic Brackets , Streptococcus mutans
9.
Chinese Journal of Neurology ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-676391

ABSTRACT

1.2 had no significant difference between the unilateral MCA-M1 stenosis group and the control group.Conclusion Transcranial Doppler can help us to analyze collateral flow on the foundation of NVUE,and can also determine the qualitative and the semi-quantitative information of collateral flow.

SELECTION OF CITATIONS
SEARCH DETAIL