Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add filters








Year range
1.
Chinese Journal of Ultrasonography ; (12): 325-331, 2022.
Article in Chinese | WPRIM | ID: wpr-932407

ABSTRACT

Objective:To investigate the safety and efficacy of transgluteal ultrasound-guided puncture and drainage in prone position in the treatment of deep pelvic abscess with pelvic adhesion.Methods:A total of 24 cases of deep pelvic abscess with pelvic adhesion treated in the ultrasound intervention room of the First Affiliated Hospital of Zhengzhou University from October 2018 to May 2021 were selected.Ultrasound-guided puncture and drainage were performed through the buttocks. The operation time, blood loss and distal limb pain during the operation were recorded. The decreasing trend of body temperature, the white blood cell, C-reactive protein and abscess size were observed. The incidence of complications such as bleeding, pain, infection and intestinal injury were counted.Results:There were 28 abscesses in 24 patients were successfully intubated through the buttocks, the abscesses disappeared after drainage, and there were no serious complications after operation. During the follow-up of 3-22 months, there was no abscess recurrence and no long-term complications.Conclusions:Ultrasound-guided transgluteal puncture and drainage is safe and effective in the treatment of deep pelvic abscess with pelvic adhesion.

2.
Chinese Journal of Ultrasonography ; (12): 1026-1030, 2012.
Article in Chinese | WPRIM | ID: wpr-430018

ABSTRACT

Objective To investigate the application value of spatio-temporal image correlation (STIC) combined with tomographic ultrasound imaging(TUI) in the prenatal diagnosis of conotruncal defects(CTD).Methods Two-dimensional(2D) fetal echocardiography to screen and TUI-STIC volumes from 1508 cases of fetuses of high risk with congenital heart disease.Postnatal work-up and pathological results were available for all fetuses with CTD.Results Thirty nine cases with CTD were found by TUI-STIC while thirty five cases were found by 2D echocardiography,but TUI-STIC had new findings and corrected the diagnosis in 9 cases as compared with 2D echocardiography.The sensitivity,specificity,positivity predictive value,negative predictive value and accuracy of TUI-STIC in evaluating CTD were 97.5 %,100%,100 %,99.9 % and 99 %.The Kappa value of consistency test between 2DE and TUI-SIC was 0.244(P < 0.01),McNemar test showed that the difference was statistically significant (P < 0.01).Conclusions TUI-STIC allows a complete sequential analysis of fetal conotruncal defects and supplying additional information over 2D fetal echocardiography,it could improve the prenatal diagnosis rate.TUI-STIC is helpful in diagnosis of prenatal conotruncal defects.

3.
Chinese Journal of Ultrasonography ; (12): 613-616, 2012.
Article in Chinese | WPRIM | ID: wpr-426686

ABSTRACT

Objective To explore the safety and effectiveness of diagnostic ultrasound associated with microbubbles to open the blood brain barrier(BBB).Methods Microbubbles were injected through caudal vein,the rat head was radiated by GE Vivid 7 diagnostic ultrasound immediately.The radiated depth was located in the basal ganglia assisted by magnetic resonance imaging(MRI)scanning.The degree of BBB opening was evaluated by enhanced MRI and Evans blue dyeing.The safety was inspected by observation of cell morphology under hematoxylin eosin(HE)staining.Results After the rat head radiated by diagnostic ultrasound with microbubbles,signal enhancement of the radiated area was observed on post contrast T1-weighted images.Red fluorescence of Evans blue was detected by fluorescence microscope in the same area.Normal cellular morphology and structural integrity were showed by HE staining.Conclusions The BBB of rat could be opened targetedly and noninvasively by diagnostic ultrasound associated with microbubbles.This may provide a new strategy for the drugs and stem cells treatment in the central nervous system diseases.

4.
Chinese Journal of Ultrasonography ; (12): 925-929, 2011.
Article in Chinese | WPRIM | ID: wpr-423224

ABSTRACT

Objective To assess the alterations of the systolic peak radial strain (RS) and the time to systolic peak radial strain(TRS) in ischemic myocardial segments with different extent of coronary artery stenosis using three-dimensional ultrasound speckle tracking imaging(3D-STI).Methods RS and TRS of 16 left ventricular segments were analyzed by 3D-STI in 87 patients,every left ventricular segment of all patients were divided into 5 groups according to coronary stenosis based on the results of selected coronary angiography:normal,≤25 %,>25 % - ≤50 %,>50 % - ≤ 75 %,> 75 %.All times were corrected by heart rate.Results In the coronary normal group,coronary stenosis extent ≤25% group and coronary stenosis extent >25% - ≤50% group,the variance of RS was non-significant( P >0.05).Compared with the coronary normal group,coronary stenosis extent ≤25% group and coronary stenosis extent > 25% -≤ 50% group,RS was decreased in groups of coronary stenosis >50% - ≤75% and >75%.Between the coronary normal group and coronary stenosis extent ≤25 % group,the variance of TRS was non-significant( P >0.05).Compared with coronary normal and coronary stenosis extent ≤25 % group,TRS was increased in groups of coronary stenosis >25% - ≤50%,>50% - ≤75%,>75%.Compared with group of coronary stenosis > 50% -≤ 75%,TRS was shorter in group of coronary stenosis > 75%,some variance was significant( P <0.05).Conclusions The RS was decreased along with the coronary stenosis increase,but TRS was increased along with the coronary stenosis increase.There is a tendency that TRS was decreased when the coronary stenosis is more than 75 % compared with the coronary stenosis >50% - ≤75 % group.3D-STI can access the regional radial systolic function of the ischemic myocardial segment.

5.
Chinese Journal of Ultrasonography ; (12): 838-841, 2011.
Article in Chinese | WPRIM | ID: wpr-422610

ABSTRACT

ObjectiveTo evaluate the effects of cardiac resynchronization therapy (CRT) on improving left ventricle (LV) function and LV asynchrony in patients with dilated cardiomyopathy(DCM)using three-dimensional ultrasound speckle tracking imaging(3D-STI).MethodsTwenty one patients with DCM and 25 normal subjects were enrolled in this study.Parameters including LV mean longitudinal peak strain (MLS),LV mean circumferential peak strain (MCS),LV mean radial peak strain (MRS),LV ejection fraction(3D-LVEF),maximal temporal difference in area strain of LV 16 segments (A-MaxTs) and its standard deviation (A-Ts-SD) were investigated by 3D-STI.LV ejection fraction (ECT-LVEF) and LV phase angle width (LVW) were obtained by radionuclide ventriculography and phase image analysis.Results The indexes of MLS,MCS,MRS and 3D-LVEF were decreased and A-MaxTs,A-Ts-SD were prolonged in DCM group compared with those of control group.There was a slightly improvement in MRS and ECTLVEF 1 week after CRT,but other Parameters including MLS,MCS,A-MaxTs,A-Ts-SD and 3D-LVEF had no significant change.Compared with corresponding values before and 1 week after CRT,all parameters (MCS,MRS,A-MaxTs,A-Ts-SD,3D-LVEF and ECT-LVEF) were further improved 6 months after CRT.MLS,MCS,MRS and 3D-LVEF had good relationship with ECT-LVEF,and A-MaxTs,A-Ts-SD had good relationship with LVW in DCM group.Conclusions3D-STI is a simple and accurate method for evaluating effects of CRT on improving LV function and LV asynchrony in patients with DCM.

6.
Chinese Journal of Ultrasonography ; (12): 490-492, 2011.
Article in Chinese | WPRIM | ID: wpr-415470

ABSTRACT

Objective To investigate the routine ultrasound and contrast-enhanced ultrasound (CEUS) features of hepatic nodules in Budd-Chiari syndrome(BCS) after portacaval anastomosis.Methods Routine ultrasonography and CEUS were performed in 18 BCS patients with hepatic nodules after portacaval anastomosis.Results Appearance after portosystemic anastomosis,multiplicity,small size,presence of peripheral rim and hypervascularization were important ultrasound imaging features of hepatic regenerative nodules in patients with BCS.Nodules showedquick wash-in and slow wash-out pattern in CEUS.Sixteen cases showed center-to-periphery enhancement pattern in arterial phase and hyper-enhancement in portal phase and late phase.Two cases showed periphery-to-center enhancement pattern in arterial phase and periphery enhancement in portal phase and late phase.Conclusions Hepatic regenerative have different features on routine ultrasound and CEUS in patients with BCS after portacaval anastomosis,which are useful for differential diagnosis.

7.
Chinese Journal of Medical Imaging Technology ; (12): 1142-1144, 2009.
Article in Chinese | WPRIM | ID: wpr-471662

ABSTRACT

Objective To observe the value of ultrasonography, MR and MSCT in diagnosing intravitreous autologous eyelashes. Methods Thirty-two New Zealand rabbits were averagely divided into 4 groups (A, B, C and D) randomly, and 1, 5, 10 eyelashes were implanted into vitreous body of rabbits respectively in group A, B, and C, whereas rabbits in group D (the control group) were only exposed to sham operation without implanting any eyelashes. After one week, all rabbits underwent ultrasound, MR and MSCT examination, then the specimens of vitreous bodies were obtained and observed pathologically. Results All the implanted intravitreous eyelashes were displayed with ultrasound. Intravitreous eyelashes in group A were not detected with MRI, whereas in 3 rabbits of group B and all of group C were displayed on T2WI, T2*WI and SWI sequences. MSCT detected intravitreous eyelashes in only 6 experimental animals. Conclusion Ultrasonography should be considered as the first choice for diagnosis of intravitreous autologous eyelashes. Different sequences of MRI have various advantages in diagnosing intravitreous autologous eyelashes, whereas the diagnostic value of MSCT is limited.

8.
Chinese Journal of Radiology ; (12): 1187-1190, 2009.
Article in Chinese | WPRIM | ID: wpr-392239

ABSTRACT

Objective To investigate the distribution of the obstructive lesion of hepatic vein and inferior cava vein in patients with Budd-Chiari syndrome in Henan Province of China.Methods A total of 231 cases with Budd-Chiari syndrome were diagnosed by combination of three imaging techniques which either included colour Dopple ultrasound,multislice CT and vasography or colour Dopple ultrasound,MR angiography and vasography.All the hepatic veins,accessory hepatic veins and inferior vena cavae were imaged and their obstructions were detected and analysed.Results Out of the 231 patients there were 5 cases(2.2%)with simple obstruction of inferior vena cava with normal hepatic branches.Thirty-three cases(14.3%)had simple hepatic vein obstruction with normal inferior vena cava.The remaining 193(83.5%)cases had vein obstruction both in hepatic vein and inferior vena cava.Conclusion The most frequent form of Budd-Chiari symdrome in Henan province of China is the complex obstruction of inferior vena cava and heptic vein,and simple obstruction of inferior vena cava occurs the least.

9.
Chinese Journal of Ultrasonography ; (12)1993.
Article in Chinese | WPRIM | ID: wpr-675832

ABSTRACT

Objective To evaluate the asynchrony of the different segments of left ventricle(LV) and its relation with LV function, QRS duration in the patients with congestive heart failure(CHF) by quantitative tissue velocity imaging(QTVI). Methods Forty normal controls and 40 patients with CHF were studied by QTVI. The regional velocity profiles of 18 segments of LV along LV apical long axis view, apical two chamber view and four chamber view were obtained. The time from onset of QRS complexes to peak velocity during systole and early diastole (T S and T E) were measured. The maximal difference in T S and T E within the same wall (Intra ?T S and Intra ?T E), the same segment (Inter ?T S and Inter ?T E ) and all 18 segments(Max ?T S and Max ?T E ) of LV were calculated. The parameters of LV function calculated included the mean of mitral annulus systolic peak velocities and early diastolic peak velocities of six wall(Mean Vs and Mean Ve), and ejection fraction of LV(LVEF). Results Inter ?T S,Inter ?T E,Intra ?T S,Intra ?T E,Max ?T S and Max ?T E in CHF group were significantly prolonged, all showing statistic significance when compared with control group(all P

10.
Chinese Journal of Ultrasonography ; (12)1993.
Article in Chinese | WPRIM | ID: wpr-539420

ABSTRACT

Objective To evaluate the value and accuracy of M-mode color Doppler echocardiography for detecting left ventricular diastolic function in patients with cardiac disease. Methods The rate of left ventricular filling flow propagation (Vp) and the early -diastolic peak velocity of the mitral annulus(E) was measured in normal subjects(n=40)and in patients with cardiac disease (n=40). All the patients had abnormal left ventricular diastolic function confirmed by isotope-angiography test. Results ① The Vp was significantly lowered in patients with cardiac disease than in normal subjects(P

SELECTION OF CITATIONS