Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedics ; (12): 1077-1083, 2022.
Article in Chinese | WPRIM | ID: wpr-957101

ABSTRACT

Objective:Comparison of four methods in intraoperative abduction angles (AA) measurements of human cast immobilization in developmental dysplasia of the hip (DDH) by visual inspection and electronic software according to different body surface markers.Methods:Data were retrospectively collected from January 2019 to November 2021 in a total of 27 patients (54 hips) who underwent closed or simple open reduction. There were 6 males and 21 females with an average age of 13.2 months. Five doctors used visual inspection and mobile phone software to measure the AA of the hip joint immediately during the operation, and compared with the postoperative MRI measurement results (AA-MRI). The four methods of intraoperative measurement were: Junior visualization (AA-JV), the intersection angle between the line connecting the center of the popliteal fossa and the contact center of the plaster frame and the line connecting the two ischial tuberosities; the same methods as method one by Senior visualization (AA-SV); the intersection angle between the line connecting the center of the popliteal fossa and the center of the anus and the line connecting the ischial tubercle (anus-popliteal, AA-AP); the intersection of the vertical line between the center of the popliteal fossa and the groin and the horizontal line of the center of the anus and the vertical line connecting the two ischial tuberosities intersect (anus-groin crease-popliteal, AA-AGCP). The t-test, correlation coefficient, linear regression and Bland-Altman test were used to evaluate the measurements. Results:Comparing the four intraoperative and postoperative AA-MRI measurement methods, AA-JV (42.69°±4.13°) < AA-SV (44.80°±4.08°) < AA-AGCP (46.25°±5.15°) < AA-MRI (47.68°±4.21°) < AA-AP (51.77°±5.30°), and the difference between AA-JV and AA-SV, AA-AP and AA-AGCP was statistically significant ( t=2.53, P=0.013; t=5.47, P=0.001), there was no significant difference between AA-AGCP and AA-MRI ( t=1.57, P=0.118). The inter-group agreement of the five methods ICC test ranged from 0.807 to 0.892, and the intra-group average agreement of AA-MRI was 0.948. All ICC results were greater than 0.75 with good agreement. Linear regression results showed that the four intraoperative measurement methods had a good or moderate linear relationship with AA-MRI, AA-AGCP ( R 2=0.499)>AA-AP ( R 2=0.318)>AA-SV ( R 2=0.253)>AA-JV ( R 2=0.217), AA-AGCP was the best measurement method. The results of Bland-Altman scatterplot of AA-AGCP and AA-MRI were in good agreement, the mean and standard deviation of bias were -0.796±3.247, and the limit of agreement was 95% LoA (-7.16, -5.57). Conclusion:The AA method of visualization before Spica casting was smaller than truth. The method AA-AGCP objectively by landmarks was the advocated means measuring abduction angle during operation with highly consistency, agreement and easily performed.

2.
Journal of China Pharmaceutical University ; (6): 274-288, 2019.
Article in Chinese | WPRIM | ID: wpr-804560

ABSTRACT

@#Small interfering RNA-based RNA interference(RNAi)is an emerging treatment which has attracted more and more attention from both academia and industry. Studies on clinical translation of siRNA are popular in biomedical field, where safe and efficient carriers are necessary. As novel drug/gene vectors, dendrimers are widely used in siRNA delivery due to their unique and precise structure, multiple terminal groups and nano-sized chemophysical properties. Here, we present an overall view of current studies on dendrimer-based siRNA delivery systems, with the aim to provide an understanding of future siRNA therapeutics which could be used in clinic.

3.
Journal of China Pharmaceutical University ; (6): 521-527, 2018.
Article in Chinese | WPRIM | ID: wpr-811751

ABSTRACT

@#In comparison with the traditional two-dimensional tumor cell culture, the three-dimensional tumor spheroid culture can not only provide with an in vivo-like growth environment for tumor cells, but also maintain maximum cell activities. Therefore, the three-dimensional tumor spheroid culture is widely used in oncology research. In particular, the three-dimensional tumor cells retain the material and structural basis of the microenvironment of tumor in vivo, which is closer to the actual physiological environment, allowing it to be an ideal in vitro model for evaluating the tumor treatment response and drug resistance in tumors. This review summarizes the mechanisms of drug resistance in three-dimensional tumor cells, especially those induced by the morphology and microenvironment of three-dimensional tumor spheres, and puts forward the problems existing in the current three-dimensional tumor cells model, as well as the future development direction.

4.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 31-42, 2018.
Article in Chinese | WPRIM | ID: wpr-712055

ABSTRACT

Objective To further improve the value of clinical application of a quantitative analysis method called LF-index (LFI) which based on real-time tissue elastography (RTE). Methods We prospectively enrolled 116 consecutive patients with chronic hepatitis B (CHB) and all patients underwent a liver biopsy and RTE between January 2015 and December 2015 at the First affiliated hospital of Wenzhou Medical University. Univariate and multivariate analyses were performed, and the prediction models for predicting significant fibrosis and cirrhosis were derived from independent predictors. Results (1) In multivariate analyses, spleno-portal index (SPI) (OR=13.956, P=0.002) and LFI (OR=6.283, P=0.023) were confirmed as independent predictors of significant fibrosis. In multivariate analyses of patients with and without cirrhosis, we found significant differences in the γ-Glutamyl transferase (GGT) (OR=1.012, P=0.049), SPI (OR=5.676, P=0.002) and LFI (OR=14.102, P=0.001). (2)A novel model called LFI-SPI score (LSPS) for prediction of significant fibrosis was developed (area under receiver operating characteristic curve [AUROC]=0.87), showing the superiority of diagnostic accuracy than LFI (AUROC=0.76, P=0.0109), aspartate aminotransferase to platelet ratio index (APRI) (AUROC=0.64, P=0.0031), fibrosis-4 index (FIB-4) (AUROC=0.67, P= 0.0044) and Fibroscan (AUROC=0.68, P=0.0021). (3) We also developed a LFI-SPI-GGT score (LSPGS) for predicting cirrhosis, with an AUROC of 0.93. The diagnostic accuracy of LSPGS was similar to that of Fibroscan (AUROC=0.85, P=0.134), and was superior to LFI (AUROC=0.81, P=0.0113), APRI (AUROC=0.67, P<0.0001), and FIB-4 (AUROC=0.72, P=0.0005). Conclusions We developed new formulas, LSPS and LSPGS for predicting significant fibrosis and cirrhosis in this prospective study. LSP score was mainly used for screening of significant liver fibrosis, and LSPG score was mainly used to exclude cirrhosis.

5.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 2167-2170, 2017.
Article in Chinese | WPRIM | ID: wpr-612477

ABSTRACT

Objective To explore the coincidence rates of positive and reverse blood group of infants younger than six months in Xiamen area in recent years,and to analyze the difference of anti-A or anti-B antibody in infants of different age groups and different ABO blood groups.Methods 2 993 hospitalized infants from 0 to 6 months in five hospitals of Xiamen area were selected.EDTA-K2 anticoagulant blood samples were collected.Micro-column gel agglutination assay was used in ABO blood group.All the infants were divided into six groups,which aged from 0-7 days,8-14 days,15-31 days,1-2 months,3-4 months and 5-6 months.The coincidence rates of positive and reverse blood group of each group were compared.Results Of the 2 993 infants,303 cases were AB type.The coincidence rates of positive and reverse blood group of the other infants which aged from 0-7 days,8-14 days,15-31 days,1-2 months,3-4 months and 5-6 months were 57.0%,61.0%,63.0%,71.8%,84.9% and 91.0%,respectively.The coincidence rates of positive and reverse blood group between different blood groups had no statistically significant difference(x2=0.842,P=0.657).The coincidence rates of positive and reverse blood group had statistically significant difference among different age groups(x2=185.683,P<0.05).Conclusion The IgM antibody of ABO blood group is detected in infants younger than six months.Positive and reverse blood group is necessary in ABO blood group identification of infants to guarantee the safety clinical blood transfusion.

SELECTION OF CITATIONS
SEARCH DETAIL