1.
Chinese Journal of Radiological Medicine and Protection ; (12): 485-488, 2011.
Article in Chinese | WPRIM | ID: wpr-424144

ABSTRACT

Objective To study the dose distribution of the radioactive 125Ⅰ seeds sources in the treatment of prostate cancer and also to explore the more effective method for improving treatment planning system (TPS).Methods Choose the designated TPS and use TLDs dosimeter based on a prostate cancer model.Finally stimulated measurement was focused on dose distribution in prostate cancer.The number of 125Ⅰ seed sources implanted was 89, each with 1.37 × 107 ( ± 5% ) Bq.Results Maximum dose of every layer ranged from 151 to 241 Gy, by 4.1% to 66.0% higher than the prescribed dose (145 Gy).The Minimum dose of every layer ranged from 101 to 128 Gy, by 12% to 30% higher than the prescribed dose.The maximum dose of normal tissue at 10 mm from the edge of model ranged from 46 to 91 Gy.The deviation was 44% -63% compared with the prescribed dose.Conclusions The designated TPS shows that it could be used as a practical guide for treatment of prostate cancer with the radioactive 125Ⅰ seed sources.The research methods offered by the study can provide evaluation of the TPS.

2.
Chinese Journal of Radiation Oncology ; (6): 468-470, 2010.
Article in Chinese | WPRIM | ID: wpr-387482

ABSTRACT

Objective To perform thermoluminescent measurements of radial dose function and anisotropy function of a newly designed 192Ir microSelectron-HDR source, and establish evaluation methods for HDR dosimetry.Methods A polystyrene phantom with sylindrical holes in different measure positions was designed to accommodate thermo luminescent dosimeter (TLD) rods and radiation source.TLD rods with similar sensitivity were placed on a semicircle around the source center which had been precisely localized by either radiographic means or dose measurement.Dose-rates were measured at θ = 90° and r = 1-14 cm to calculate radial dose function (gL (r)), while measured along polar angles θ = 0° -165°(interval 15°) at radial distances r = 1 cm, 3 cm and 5 cm to calculate anisotropy function (F(r,θ)).All data were compared with those calculated by Monte Carlo (MC) method.The t-test was used for the statistics.Results The values of gL (r) were 1.007 -0.681 by calculation and 1.007 -0.598 by measurement with r = 1 - 14 cm(t = 0.00 - 2.89, all P > 0.05).The values of F (r,θ) were 0.631 - 1,0.660 - 1 and 0.696 - 1 by calculation, while 0.701 - 1, 0.668 - 1 and 0.629 - 1 by measurement at 1 cm, 3 cm and 5 cm with θ=0° -165°(t=0.40 -1.63, 0.02 -2.10, 0.08 -2.03, all P>0.05).Conclusions The results of radial dose function and anisotropy function measured by TLD measurement are in consistent with those calculated by MC calculations, which can be applied in treatment planning system as original input.

3.
Journal of Environment and Health ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-674708

ABSTRACT

To measure the levels of X ray radiation emitted from computer video display terminals Accumulative doses of X ray radiation emitted from the surface of terminal screen and radiation protcetive screen were measured by highly sensitive LiF(Mg,Cu,P) thermoluminescent dosimetry The average levels of X ray radiation emitted from the surface of terminal screen and radiation protective screen were 0 93 mR/d and 0 24 mR/d respectively [Conclusion]The low energy and low level X ray radiation emitted from the terminals didn′t exceed the related standards