Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Biosci. j. (Online) ; 36(1): 310-315, jan./feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1049253

ABSTRACT

The aim of this study was to evaluate the effect of different commercial silanes on microshear bond strength of resin cement to lithium disilicate ceramic. Twenty ceramic samples with 10 mm in length, 10 mm wide and 3 mm in thickness were fabricated, etched with 10% hydrofluoric acid for 20 seconds, and divided into 5 groups, according to the commercial silane applied: G1- RelyX Ceramic Primer (3M ESPE), G2- Angelus Silane, G3- Prosil (FGM), G4- Dentsply Silane (Dentsply) and G5- Bis-Silane (Bisco). Silanes were applied in accordance to manufacturers' recommendations. Addition silicone molds with 1 mm in thickness, 10 mm in diameter and 3 perforations with 1 mm in diameter each one, were placed on ceramic and filled with the resin cement RelyX ARC (3M ESPE) in all groups. Light activation was performed with LED Bluephase G2 (Ivoclar Vivadent) at 1200 mW/cm2, for 30 seconds. Samples were maintained in 100% humidity at 37°C for 24 hours and submitted to microshear test. The data (MPa) were submitted to one-way ANOVA and Tukey test (α=0.05). The results obtained for each group were: G1: 22.39±2.99; G2: 23.35±4.08; G3: 26.05±5.46; G4: 18.56±4.09; G5: 25.26±4.10. Statistical analysis showed significantly lower microshear bond strength for G4. Fracture pattern analysis showed predominance of adhesive failures in G1 and G2. G3 and G5 presented higher percentage of cohesive failures in ceramic, and G4 showed mixed, adhesive and cohesive fractures with similar percentages. It was concluded that different silanes showed influence on the lithium disilicate ceramic ­ resin cement bond strength


O objetivo neste estudo foi avaliar o efeito de diferentes silanos comerciais na resistência de união ao microcisalhamento do cimento resinoso à cerâmica de dissilicato de lítio. Foram confeccionadas 20 amostras de cerâmica (10mm de comprimento, 10mm de largura e 3mm de espessura), condicionadas com ácido fluorídrico a 10% por 20 segundos e divididas em 5 grupos, de acordo com o silano aplicado: G1- RelyX Ceramic Primer (3M ESPE), G2- Silano Angelus, G3-Prosil (FGM), G4- Silano Dentsply e G5-Bis-Silane (Bisco). Matrizes de silicone por adição (1 mm de espessura, 10 mm de diâmetro e 3 perfurações com 1 mm de diâmetro) foram colocadas sobre a cerâmica e preenchidas com cimento resinoso RelyX ARC (3M ESPE). A fotoativação foi realizada com LED Bluephase G2 (Ivoclar Vivadent) a 1200 mW/cm2, por 30 segundos. As amostras foram mantidas em 100% de umidade a 37°C por 24 horas e submetidas ao teste de microcisalhamento. Os dados (MPa) (G1: 22,39+2,99; G2: 23,35+4,08; G3: 26,05+5,46; G4: 18,56+ 4,09; G5: 25,26+4,10) foram submetidos a análise de variância e ao teste de Tukey (p<0,05). A análise estatística mostrou valor de resistência de união significantemente menor para G4. A análise do padrão de fratura mostrou predominância de falha adesiva para G1 e G2. G3 e G5 apresentaram maior porcentagem de falha coesiva em cerâmica, e o G4 apresentou fraturas mista, adesiva e coesiva em igual porcentagem. Concluiu-se que os diferentes silanos apresentaram influência na resistência de união do cimento resinoso à cerâmica de dissilicato de lítio


Subject(s)
Silanes , Ceramics , Dental Cements , Shear Strength , Lithium , Silicate Cement , Cementation , Resin Cements , Dental Porcelain
2.
RFO UPF ; 13(1): 80-85, jan.-abr. 2008. tab
Article in Portuguese | LILACS, BBO | ID: lil-487416

ABSTRACT

Desde o início do emprego das cerâmicas em restaurações indiretas, a odontologia passou a viver uma nova realidade. Na busca pelo aperfeiçoamento desses materiais surgiram as coroas protéticas de cerâmicas reforçadas por vidro, que possuem maior resistência à fratura, porém apresentam dificuldades no condicionamento superficial prévio aos procedimentos cimentadores. Objetivando apontar um protocolo de condicionamento superficial e de cimentação adesiva deste tipo de material, o presente trabalho traz uma revisão de literatura acerca das diferentes técnicas de tratamento de superfície interna de coroas protéticas de cerâmicas reforçadas por vidro. Os principais métodos empregados e que merecem ser discutidos são os jateamentos com óxido de alumínio e partículas de sílica, bem como a palicação de ácido fluorídrico e a silanização. Atualmente, as pesquisas têm apontado para a silicatização como o meio mais eficiente para prover a retenção entre este tipo de material e o remanescente dentário, quando procedimentos de cimentação adesiva são empregados. Os cimentos que possuem monômeros fosfatados também apresentam evidências de serem mais efetivos neste tipo de cimentação e têm sido indicados com sucesso.


Subject(s)
Ceramics , Dental Cements
3.
Braz. dent. j ; 19(4): 334-340, 2008. ilus, tab
Article in English | LILACS | ID: lil-504197

ABSTRACT

This study evaluated the bond strength and Knoop hardness of Z250 composite resin, light activated with XL2500 curing unit, using different protocols: continuous mode - high intensity (CH) (700 mW/cm²) for 20 s; continuous mode - low intensity (CL) (150 mW/cm²) for 20 s; and pulse-delay with 150 mW/cm² for 2(P2), 3(P3), 5(P5), 10(P10) or 15 s (P15), with a 1-min delay, followed by 700 mW/cm² for 20 s. For the push-out test (n=10), the bond strength values were obtained using a universal test machine at a crosshead speed of 0.5 mm/min. For Knoop hardness (n=5), the specimens were made using the same light-activation protocols. The hardness measurements were made with a hardness tester at six depths (top, 1, 2, 3, 4, and 5 mm). The data were subjected to ANOVA and Tukey's test at 5 percent significance level. For bond strength, CL and P5 presented significantly higher mean values (p<0.05) than the other groups. There was no statistically significant difference (p>0.05) between P2, P3, P10, P15 and CH. For Knoop hardness, CH and P15 presented the highest mean values from top surface up to 4 mm depth , while CL presented the lowest hardness mean values (p<0.05). From the depth of 3 mm to 5 mm, the mean values of all groups were significantly lower (p<0.05) than those recorded on top surface. In conclusion, for the pulse-delay method, the initial exposure time can influence bond strength and Knoop hardness of composites.


Este estudo verificou a resistência de união e a dureza Knoop do compósito Z250 (3M/ESPE), fotoativado com luz de lâmpada halógena (XL2500, 3M/ESPE), utilizando diferentes protocolos: modo contínuo alta intensidade (CH) (700mW/cm²) por 20s; modo contínuo baixa intensidade (CL) (150mW/cm²) por 20s; pulse-delay com 150mW/cm² por 2(P2), 3(P3), 5(P5), 10(P10) ou 15(P15) segundos, com 1 min de espera, seguido por 700mW/cm² por 20s. Para o teste de união push-out (n=10), os valores de resistência de união foram obtidos em máquina de ensaio universal Instron. Para o ensaio de dureza Knoop (n=5) os espécimes foram fotoativados pelos mesmos protocolos utilizados no ensaio de resistência de união. As medidas de dureza foram realizadas em um microdurômetro (Shimadzu) em 6 profundidades (topo, 1, 2, 3, 4 e 5 mm). Os dados foram submetidos à Análise de Variância e ao teste de Tukey com nível de significância de 5 por cento. Os resultados mostraram que P5 e CL apresentaram resistência de união estatisticamente superior a todos os grupos. Não houve diferença entre os grupos P2, P3, P10, P15 e CH. Para dureza Knoop, CH apresentou os maiores valores, estatisticamente superiores a P2 e CL até 4 mm. A partir de 3 mm, a dureza de todos os grupos foi inferior a dureza do topo. O tempo de exposição inicial para o modo pulse-delay pode influenciar a resistência de união e a dureza Knoop.


Subject(s)
Composite Resins/radiation effects , Light-Curing of Dental Adhesives/methods , Dentin-Bonding Agents/radiation effects , Resin Cements/radiation effects , Dental Stress Analysis , Dental Restoration, Permanent/methods , Hardness , Materials Testing , Phase Transition , Time Factors
4.
RGO (Porto Alegre) ; 54(3): 274-279, set.-out. 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-457235

ABSTRACT

O uso da técnica da zona neutra tem demonstrado bastante eficiência clínica, principalmente em prótese total mandibular, onde a reabsorção do rebordo apresenta-se bastante grande. Esta técnica permite distribuir os dentes artificiais, de forma adequada biomecanicamente em relação ao rebordo alveolar e à musculatura paraprotética, proporcionando assim, melhores resultados estéticos, fonéticos e maior facilidade de adaptação. Como esta técnica proporciona maior conforto ao paciente, o grau de satisfação em relação ao tratamento é maior.


Subject(s)
Humans , Female , Middle Aged , Dental Prosthesis Retention , Denture, Complete
5.
J. Health Sci. Inst ; 15(1): 53-5, jan.-jun. 1997.
Article in Portuguese | LILACS, BBO | ID: biblio-851128

ABSTRACT

Trata-se de um caso clínico típico do cisto odontogênico calcificante, ocorrido em pacientes do sexo masculino, 53 anos, leucoderma, com lesão localizada na região de primeiro bicúspide inferior esquerdo, que após biópsia foi removido por enucleação. O objetivo deste trabalho é acrescentar à literatura mais um caso clínico de COC e, assim, colaborar com outros estudos, frente a esta entidade


Subject(s)
Humans , Male , Middle Aged , Odontogenic Cyst, Calcifying/diagnosis , Ameloblastoma , Odontogenic Cyst, Calcifying/complications
SELECTION OF CITATIONS
SEARCH DETAIL