Ortodontia ; 45(5): 498-504, set.-out. 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-714065

ABSTRACT

O objetivo deste estudo foi avaliar a precisão do torque detubos metálicos na prescrição MBT, utilizando os segundos molaresinferiores como amostra representativa de quatro marcas comerciais.Quatro marcas que produzem tubos na prescrição foram selecionadas:Abzil, Aditek, American Orthodontics e 3M Unitek. Foram usados 20tubos de cada marca, constituindo 80 tubos. As imagens ampliadasdo perfil dos tubos foram obtidas por um único operador com autilização de um microscópio eletrônico de varredura, e os ângulosforam mensurados empregando-se o software AutoCAD 2008 (32Bit).Oângulo vestibulolingual foi estabelecido pela mensuração dos ângulosAPO (ângulo da parede oclusall e APC (ângulo da parede cervicall, eforam comparados aos valores de referência de -10°. Na avaliação dainclinação vestibulolingual por meio do ângulo APC, as marcas Abzil,American Orthodontics e 3M Unitek encontravam-se em conformidadecom a prescrição e eram semelhantes entre si. Para o ângulo APO,apenas a marca 3M Unitek ficou em conformidade com a prescrição,sem diferença estatística (p > 0,05).


The aim of the present study was to verify the torqueprecision of metallic tubes with MBT prescription using the lower secondmolars as the representa tive sample of four commercial brands. Fourtrademarks that provide MBT prescription tubes were selected: Abzil,Aditek, American Orthodontics, 3M Unitek. Twenty tubes each trademarkwere used, comprising 80 tubes. The enlarged images of the profile ofthe tubes were obtained by a single operator using a scanning electronmicroscope and the angles were measured using AutoCAD 2008 (32Bit).The bucco lingual angle was established by measuring the APO angles(angle of the oclusal wall) and were (angle of the cervical wall) and werecompared to reference values of -10°. In assessing the bucco lingualinclination angle by APC, the marks Abzil, American Orthodontics and3M Unitek were in accordance with the prescription and were similar. Forthe angle APO, only 3M Unitek was in accordance with the prescription,without statistical difference (p > 0.05).


Subject(s)
Molar , Torque , Data Interpretation, Statistical , Materials Testing , Dental Materials/analysis , Microscopy, Electron, Scanning
SELECTION OF CITATIONS
SEARCH DETAIL